Engineering PapersSearch

Engineering topics

H S Alpert

Publications and source records attributed to H S Alpert.

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert

Variance Decomposition of MEDLI2 Reconstructed Heating Using Neural Networks

The Mars Entry, Descent, and Landing Instrumentation (MEDLI2) sensor suite collected data during entry of the Mars 2020 Perseverance rover into Mars’ atmosphere. An inverse estimation of the backshell and heatshield surface aeroheating was performed, using the data from the MEDLI2 Instrumented Sensor Plugs, a network of thermocouples embedded within the thermal protection system across the aeroshell. Monte Carlo analysis was conducted to assess the sensitivity of the surface heat rate, temperature, and heat load to uncertainties in thermocouple depth and material properties. In this paper, a variance decomposition method using Sobol indices was employed to understand the relative contributions of each uncertainty parameter. Performing this analysis using results from the inverse analysis tool FIAT_Opt was found to require incredibly high computation time, and thus machine learning models were trained and evaluated as a surrogate model for FIAT_Opt. This paper demonstrates that machine learning models can be an efficient, accurate alternative to state-of-the-art inverse analysis tools like FIAT_Opt, especially for computationally-expensive processes. Using these models, the sensitivity analysis showed that uncertainties in heat capacity and thermal conductivity were the main drivers for the overall uncertainty in peak reconstructed heating and heat load.

H S Alpert

Overview and Performance of the LOFTID Instrumentation Suite

NASA’s Hypersonic Inflatable Aerodynamic Decelerator (HIAD) is an enabling technology that facilitates atmospheric entry of heavy payloads to planets such as Earth and Mars using a deployable aeroshell. The deployable nature of the HIAD technology allows it to overcome the size constraints imposed on current rigid aeroshell entry systems. This enables use of larger aeroshells resulting in increased entry system performance (e.g. higher payload mass and/or volume, higher landing altitude at Mars). On November 10th, 2022 the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) was launched out of Vandenberg Air Force Base as a secondary payload on an Atlas V rocket. After the primary payload was delivered to its orbit, the LOFTID reentry vehicle was inflated, positioned, and then separated to reenter Earth’s atmosphere at a velocity of 8.1km/s, ultimately splashing down safely in the Pacific Ocean. The flight successfully demonstrated a 6m diameter, 70-deg sphere-cone HIAD on a high-energy orbital reentry. This demonstration has provided invaluable fight data essential to characterize the vehicle performance and support the ongoing effort to further scale the HIAD technology to vehicles of 10m in diameter or greater. Aeroshells of this scale are applicable to near-term commercial applications and future NASA robotic and human exploration missions. LOFTID incorporated an extensive instrumentation suite totaling over 150 science measurements. This included thermocouples, total heat flux sensors, and a radiometer to characterize the aeroheating environment and aeroshell thermal response. An Inertial Measurement Unit (IMU), Global Positioning System (GPS), and flush air data system was included to allow post-flight reconstruction of the vehicle trajectory including a decoupling of the aerodynamics from the atmospheric density. Loadcells were used to measure HIAD structural response during entry, and cameras (both visual-spectrum and infrared) were mounted on the aft segment looking at the aeroshell to monitor structural deflection and surface temperature distribution. Finally, a single up-look camera was included which has provided a surprising amount of science potential from the spectacular footage. In addition to the primary instrumentation suite, a new Fiber Optic Sensing System (FOSS) was used to provide global temperature distributions as a technology demonstration. The system provided over 200 thermal measurements creating a thermal map for the backside of the nose Flexible Thermal Protection System. Another pair of FOSS cables were run along the rigid center structure and measured the temperature response to the vehicle wake environment. The LOFTID instrumentation suite leveraged Agency-wide expertise, with hardware development occurring at Ames Research Center, Langley Research Center, Marshall Space Flight Center, and Armstrong Flight Research Center. This presentation will discuss the instrumentation selected for LOFTID to capture the HIAD performance during the high-energy orbital reentry flight test, provide examples of data products, and snippets of the spectacular reentry video.

G T Swanson

LOFTID Surface Heating Reconstruction

On November 10, 2022, the Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) reentry vehicle launched to low-Earth orbit aboard a United Launch Alliance Atlas V rocket out of Vandenberg Air Force Base. The aeroshell, the largest Hypersonic Inflatable Aerodynamic Decelerator (HIAD) ever flown, was inflated to its full 6-meter diameter before successful re-entry into the atmosphere. The aeroshell was heavily instrumented in order to understand its behavior during entry. There were 82 thermocouples (TCs) distributed across the aeroshell, with 22 integrated into the flexible thermal protection system (FTPS) on the rigid nose, 36 in the FTPS on the deployable structure, and 24 on the inflatable structure. TCs were placed at different depths throughout the FTPS. Those nearest to the surface were located just beneath the two SiC outer fabric layers. The near-surface TCs on the rigid nose were Type R with flame spray alumina insulation, while those on the flank were Type N with mica/ceramic insulation. Additionally, a radiometer was placed at the center of the nose surrounded by four total heat flux gauges in a cruciform configuration at a radius of 0.41 m. The nose instrumentation is shown in Fig. 1 and a cross-section of the aeroshell with all TC locations is shown in Fig. 2. The objective of this work was to use the temperatures measured by the TCs during flight to estimate the surface heat rate across the aeroshell throughout the period of re-entry by inverse analysis methodology. The results were used to evaluate the fidelity of measurements from the total heat flux gauges on the nose, determine the surface heat flux at aeroshell locations where gauges were not present, and compare to pre-flight CFD-based heating predictions. Inversely estimated surface heat flux continues to be used to correlate FTPS thermal models to reconstruct in-flight thermal response.

H S Alpert