Site-Directed Research & Development Annual Report Overview FY 2023
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Guss, Paul P..
Explore the source record for details and available documents.
Publicly viewable and releasable version of the briefing on DHS- and global security-relevant SDRD projects that will be given during the Feb 27 DHS visit.
Presents work under SDRD feasibility studies FS-23-130 using ground based robots to survey radiologically contaminated area
Explore the source record for details and available documents.
A team of scientists from the Remote Sensing Laboratory at Joint Base Andrews, Maryland, has assembled a remote-controlled robot to field a few sodium iodide scintillators of different size and shape 18″ above ground for measurement of ground deposition of gamma-emitting particles after an explosion of a radiological dispersal device. This system uses a high-precision differential GPS device with submeter accuracy for radiation mapping. The system is most useful in characterizing large-area contamination and detecting gamma radioactivity in invisible, submicron particulate debris deposited on the ground at surface level or embedded in subsurface up to 3″ deep. The system was assembled as part of a larger effort to integrate advanced radiological detection devices into autonomous or remote-controlled robotic systems to eliminate or minimize the need for emergency responders to enter areas that pose significant health and safety risks to humans following a major radiological incident or accident. Research into autonomous algorithms is required to develop automated robotic systems for radiological survey and characterization activities in highly contaminated areas. The scope of this project also includes developing communications pathways and supporting infrastructure capabilities for different types of robotic technologies. The expected result is an advanced autonomous robotic system with integrated radiation detection electronics that allows emergency response personnel to view data remotely and in real time for radiological emergency response and consequence management purposes.
Presentation to be submitted to and presented during the Health Physics Society (HPS) Annual Meeting 2023, July 23–27, 2023, National Harbor, MD (http://burkclients.com/hps/2023AM/site/index.html).
Explore the source record for details and available documents.
This project seeks to develop low-cost, high-resolution gamma scintillators based on new fracture-resistant alloys of cerium bromide. These alloys will eliminate limitations imposed by self-activity and fracture of currently available lanthanum-based scintillators.
A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2" × 4" × 16" sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.
An aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal was prepared with a gamma-energy resolution (FWHM) of 3.2% at the 137Cs 662 keV gamma energy. We completed a crystal assessment and calculated the predictive performance and physical characteristics using density functional theory (DFT) formalism. Detector performance, characteristics, calcium doping concentration, and crystal strength are reported. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. Specifically, we see excellent linearity of photons per unit energy with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality for doped CeBr3, however, appears to be similar to that of undoped CeBr3. The new crystal was subjected to additional testing and evaluation, including a benchmark spectroscopy assessment. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain energy resolution of 3.2% before packing the crystallite in a sealed detector container and 4.5% after packing. Spectra were also obtained for 241Am, 60Co, 228Th, and background to illustrate the spectrosocopic quality of CeBr3:Ca2+ over a broader energy range.
Explore the source record for details and available documents.
The problem of accurately detecting extremely low levels of nuclear radiation is rapidly increasing in importance in nuclear counter-proliferation, verification, and environmental and waste management. Because the 239Pu gamma signature may be weak, for instance, even when compared to the natural terrestrial background, coincidence counting with the 239Pu neutron signature may improve overall 239Pu detection sensitivity. However, systems with sufficient multiple-particle detectors require demonstration that the increased sensitivity be sufficiently high to overcome added cost and weight. We report the results of measurements and calculations to determine sensitivity that can be gained in detecting low levels of nuclear radiation from use of a relatively new detector technology based on elpasolite crystals. We have performed investigations exploring cerium (Ce3+)-doped elpasolites Cs2LiYCl6:Ce3+0.5% (CLYC) and Cs2LiLa(Br6)90%(Cl6)10%:Ce3+0.5% (CLLBC:Ce). These materials can provide energy resolution (r(E) = 2.35σ(E)/E) as good as 2.9% at 662 keV (FWHM). The crystals show an excellent neutron and gamma radiation response. The goals of the investigation were to set up the neutron/gamma pulse shape discrimination electronics for elpasolite detectors; perform limited static source benchmarking, testing, and evaluation to validate system performance; and explore application of a maximum likelihood algorithm for source location. Data were measured and processed through a maximum likelihood estimation algorithm, providing a direction to the radioactive source for each individual position. The estimated directions were good representations for the actual directions to the radioactive source. This paper summarizes the maximum likelihood results for our elpasolite system.
The Remote Sensing Laboratory (RSL) is developing a tactical, networked radiation detection system that will be agile, reconfigurable, and capable of rapid threat assessment with a high degree of fidelity and certainty. Our design is driven by the needs of users such as law enforcement personnel who must make decisions by evaluating threat signatures in urban settings. The most efficient tool available to identify the nature of the threat object is real-time gamma spectroscopic analysis, as it is fast and has a very low probability of producing false positive alarm conditions. Urban radiological searches are inherently challenged by the rapid and large spatial variation of background gamma radiation, the presence of benign radioactive materials in terms of the normally occurring radioactive materials (NORM), and shielded and/or masked threat sources. Multiple spectral anomaly detection algorithms have been developed by national laboratories and commercial vendors. For example, the Gamma Detector Response and Analysis Software (GADRAS) a one-dimensional deterministic radiation transport software capable of calculating gamma ray spectra using physics-based detector response functions, was developed at Sandia National Laboratories. The nuisance-rejection spectral comparison ratio anomaly detection algorithm (or N-SCRAD), developed at Pacific Northwest National Laboratory, uses spectral comparison ratios to detect deviation from benign medical and NORM radiation source and can work in spite of strong presence of NORM and or medical sources. RSL has developed its own wavelet-based gamma energy spectral anomaly detection algorithm called WAVRAD. Test results and relative merits of these different algorithms will be discussed and demonstrated.
Explore the source record for details and available documents.
A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2' × 4' × 16' sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart realtime localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We are testing a collection of algorithms and analysis on the problem of radiation detection with a distributed sensor network, examining such a network’s associated characteristics, and also the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, are being examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.
Explore the source record for details and available documents.
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10 B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions of neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3 He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10 B (in the form of enriched boron carbide: 10 B 4 C) for neutron detection instead of 3 He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.
Explore the source record for details and available documents.