Engineering Papers⌕ Search

Engineering topics

Gueorguiev, Andrey

Publications and source records attributed to Gueorguiev, Andrey.

Low-cost, multi-mode detector solutions

Low-cost radiation detectors capable of providing efficient gamma-ray and neutron detection are essential in passive nuclear monitoring systems such as radiation portal monitors (RPMs) and detection of Special Nuclear Materials (SNM) through Active Interrogation (AI). Here, three low-cost detector solutions are discussed—(1) Large-area polystyrene-based plastic scintillators for AI (2) Pulse Shape Discrimination (PSD) capable plastic scintillators doped with heavy-metals for imparting gamma-ray spectroscopy (3) Composite detector technology based on inorganic scintillator submerged into the plastic scintillator, for detection of thermal and fast neutrons in addition to gamma-ray spectroscopy. Composite detectors using inorganic component such as Cs 2 LiYCl 6 (CLYC), Cs 2 LiLaBr x Cl 6-x (CLLBC), or CsI:Tl have been developed up to 4” sizes. Neutron and gamma efficiencies are compared for samples with different inorganic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo investigation of a high-efficiency, two-plane Compton camera for long-range localization of radioactive materials

Compton cameras have become an instrument of interest for long-range localization of radioactive materials in nuclear-nonproliferation applications. In this work, a specialized simulation tool was developed for the optimization of a Compton camera through realistic Monte Carlo simulations. This tool can be used for Compton cameras with different geometries. The MCNPX-PoliMi code was used to simulate Compton scatters and photoelectric absorptions in the camera's detectors. The imaging capability is derived from the physics of Compton scattering and the full-energy information obtained in photoelectric absorptions. The simulated system is a 1 1 m2 Compton camera consisting of two planar arrays of photon detectors. Several scintillators were evaluated: LaBr3, CaF2, and NaI(Tl) (all inorganic scintillators), and C9H10 (plastic organic scintillator). The investigation was carried out with a 137Cs source. A minimum detectable activity (MDA) was defined and used to assess the performance of cameras based on different detectors. The simulation results show that C9H10 is a reliable, low-cost, scatter-plane material, increasing the MDA by ~0.2 mCi when compared to a CaF2 scatter plane. On the other hand, the intrinsic background of LaBr3 undermines its above-average energy resolution as the MDA increased by ~0.5 mCi when compared to a NaI(Tl) absorption plane.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗