Engineering Papers⌕ Search

Engineering topics

Green, Robert O.

Publications and source records attributed to Green, Robert O..

At least 163 records · Page 9

Imaging spectrometer measurement of water vapor in the 400 to 2500 nm spectral region

The Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) measures the total upwelling spectral radiance from 400 to 2500 nm sampled at 10 nm intervals. The instrument acquires spectral data at an altitude of 20 km above sea level, as images of 11 by up to 100 km at 17x17 meter spatial sampling. We have developed a nonlinear spectral fitting algorithm coupled with a radiative transfer code to derive the total path water vapor from the spectrum, measured for each spatial element in an AVIRIS image. The algorithm compensates for variation in the surface spectral reflectance and atmospheric aerosols. It uses water vapor absorption bands centered at 940 nm, 1040 nm, and 1380 nm. We analyze data sets with water vapor abundances ranging from 1 to 40 perceptible millimeters. In one data set, the total path water vapor varies from 7 to 21 mm over a distance of less than 10 km. We have analyzed a time series of five images acquired at 12 minute intervals; these show spatially heterogeneous changes of advocated water vapor of 25 percent over 1 hour. The algorithm determines water vapor for images with a range of ground covers, including bare rock and soil, sparse to dense vegetation, snow and ice, open water, and clouds. The precision of the water vapor determination approaches one percent. However, the precision is sensitive to the absolute abundance and the absorption strength of the atmospheric water vapor band analyzed. We have evaluated the accuracy of the algorithm by comparing several surface-based determinations of water vapor at the time of the AVIRIS data acquisition. The agreement between the AVIRIS measured water vapor and the in situ surface radiometer and surface interferometer measured water vapor is 5 to 10 percent.

Green, Robert O.↗

Comparison Of Measurments Of Atmospheric Water Vapor

Report presents experimental intercomparison among measurements by four spectrometric instruments for determining concentration of atmospheric water vapor. Three instruments ground-based and needed to provide independent data to calibrate and validate measurements taken by fourth instrument, which is airborne visible/infrared imaging spectrometer (AVIRIS). Remote down-looking instruments like AVIRIS increases accuracy and coverage of water-vapor measurements.

Bruegge, Carol J.↗

Geometric and radiometric preprocessing of airborne visible/infrared imaging spectrometer (AVIRIS) data in rugged terrain for quantitative data analysis

A geocoding procedure for remotely sensed data of airborne systems in rugged terrain is affected by several factors: buffeting of the aircraft by turbulence, variations in ground speed, changes in altitude, attitude variations, and surface topography. The current investigation was carried out with an Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) scene of central Switzerland (Rigi) from NASA's Multi Aircraft Campaign (MAC) in Europe (1991). The parametric approach reconstructs for every pixel the observation geometry based on the flight line, aircraft attitude, and surface topography. To utilize the data for analysis of materials on the surface, the AVIRIS data are corrected to apparent reflectance using algorithms based on MODTRAN (moderate resolution transfer code).

Meyer, Peter↗

Radiative transfer code based estimation of atmospheric parameters for inversion of imaging spectrometer measured radiance to apparent surface reflectance

Surface reflectance is required to quantitatively investigate molecular absorption and particle scattering properties of materials on the Earth's surface. Atmospheric aerosol optical depth, surface pressure and water vapor are required to constrain a radiative transfer code for the inversion of measured spectral radiance to apparent surface reflectance. A suite of algorithms using nonlinear least squares fitting techniques are described that directly estimate these atmospheric parameters from spectral radiance measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). The derived atmospheric parameters are used to constrain a radiative transfer code for the inversion of the imaging spectrometer radiance to apparent reflectance. The derived apparent reflectance is validated with respect to in situ measurement on the same target.

Green, Robert O.↗

Summaries of the 4th Annual JPL Airborne Geoscience Workshop. Volume 1: AVIRIS Workshop

This publication contains the summaries for the Fourth Annual JPL Airborne Geoscience Workshop, held in Washington, D. C. October 25-29, 1993 The main workshop is divided into three smaller workshops as follows: The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) workshop, October 25-26 (the summaries for this workshop appear in this volume, Volume 1); The Thermal Infrared Multispectral Scanner (TMIS) workshop, on October 27 (the summaries for this workshop appear in Volume 2); and The Airborne Synthetic Aperture Radar (AIRSAR) workshop, October 28-29 (the summaries for this workshop appear in Volume 3).

Green, Robert O.↗

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS): Recent improvements to the sensor

AVIRIS is a NASA-sponsored Earth-looking imaging spectrometer designed, built and operated by the Jet Propulsion Laboratory. Spectral, radiometric and geometric characteristics of the data acquired by AVIRIS are given in Table 1. AVIRIS has been operational since 1989, however in each year since 1989 major improvements have been completed in most of the subsystems of the sensor. As a consequence of these efforts, the capabilities of AVIRIS to acquire and deliver calibrated imaging spectrometer data of high quality have improved significantly over those in 1989. Improvements to AVIRIS prior to 1992 have been described previously (Porter et al., 1990, Chrien et al., 1991, & Chrien et al., 1992). In the following sections of this paper we describe recent and planned improvements to AVIRIS in the sensor task.

Chrien, Thomas G.↗

Comparison of methods for calibrating AVIRIS data to ground reflectance

We are comparing three basic methods of calibrating AVIRIS data to ground reflectance: (1) atmospheric radiative transfer models with the solar flux can be used to calibrate AVIRIS radiance data (Specific methods include the University of Colorado CSES ARP and ATREM algorithms); (2) Robert Green's modified MODTRAN and AVIRIS radiance model (This method is similar to 1 but differs in that the solar radiance is bypassed, so any errors in the solar flux are canceled, too); and (3) ground calibration using known sites in the AVIRIS scene. We are using 1992AVIRIS data over Cuprite, Nevada, and Blackhawk Island, Wisconsin, as our test scenes. Both these sites have extensive field measurements. The Cuprite site had a very clear atmosphere, thus path radiance was dominated by Rayleigh scattering with little or no flux beyond 1 micron. The Blackhawk site has more aerosols, with significant path radiance flux beyond 2 micron.

Clark, Roger N.↗

Remote sensing of smoke, clouds, and fire using AVIRIS data

Clouds remain the greatest element of uncertainty in predicting global climate change. During deforestation and biomass burning processes, a variety of atmospheric gases, including CO2 and SO2, and smoke particles are released into the atmosphere. The smoke particles can have important effects on the formation of clouds because of the increased concentration of cloud condensation nuclei. They can also affect cloud albedo through changes in cloud microphysical properties. Recently, great interest has arisen in understanding the interaction between smoke particles and clouds. We describe our studies of smoke, clouds, and fire using the high spatial and spectral resolution data acquired with the NASA/JPL Airborne Visible/Infrared Imaging Spectrometer (AVIRIS).

Gao, Bo-Cai↗

Use of data from the AVIRIS onboard calibrator

The AVIRIS onboard calibrator became operational in 1992. This subsystem on the AVIRIS sensor has operated nominally throughout the 1992 and 1993 flight season. This paper describes the data measured by the onboard calibration and the two primary uses of these data. First, the data may be used to optimize the tractability of the calibration of the delivered AVIRIS data to the laboratory radiometric calibration standard. Second, these data may be used to monitor and normalize the inflight radiometric performance of AVIRIS through the flight season.

Green, Robert O.↗

Inflight calibration of AVIRIS in 1992 and 1993

In order to pursue the quantitative research objective of AVIRIS, the spectral, radiometric characteristic of the sensor must be known at the time of flight data acquisition. AVIRIS is rigorously calibrated in the laboratory. In addition, three times each year these characteristics of AVIRIS are validated through an inflight calibration experiment. Absolute radiometric calibration and signal-to-noise results are present for the inflight calibration experiment orchestrated in 1992 and 1993.

Green, Robert O.↗

Estimation of aerosol optical depth and additional atmospheric parameters for the calculation of apparent reflectance from radiance measured by the Airborne Visible/Infrared Imaging Spectrometer

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spatial images of the total upwelling spectral radiance from 400 to 2500 nm through 10 nm spectral channels. Quantitative research and application objectives for surface investigations require inversion of the measured radiance of surface reflectance or surface leaving radiance. To calculate apparent surface reflectance, estimates of atmospheric water vapor abundance, cirrus cloud effects, surface pressure elevation, and aerosol optical depth are required. Algorithms for the estimation of these atmospheric parameters from the AVIRIS data themselves are described. From these atmospheric parameters we show an example of the calculation of apparent surface reflectance from the AVIRIS-measured radiance using a radiative transfer code.

Green, Robert O.↗

Use of the Airborne Visible/Infrared Imaging Spectrometer to calibrate the optical sensor on board the Japanese Earth Resources Satellite-1

We describe an experiment to calibrate the optical sensor (OPS) on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). On 27 Aug. 1992 both the OPS and AVIRIS acquired data concurrently over a calibration target on the surface of Rogers Dry Lake, California. The high spectral resolution measurements of AVIRIS have been convolved to the spectral response curves of the OPS. These data in conjunction with the corresponding OPS digitized numbers have been used to generate the radiometric calibration coefficients for the eight OPS bands. This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.

Green, Robert O.↗

A proposed update to the solar irradiance spectrum used in LOWTRAN and MODTRAN

The calibrated upwelling radiance spectra measured by AVIRIS are increasingly being analyzed with radiative transfer codes. Analysis of AVIRIS data with the LOWTRAN and MODTRAN radiative transfer codes has led to indications of an error in the solar irradiance spectra used by these codes. This paper presents evidence for the error and proposed update to the solar irradiance spectra used by LOWTRAN and MODTRAN.

Green, Robert O.↗

A role for AVIRIS in the Landsat and Advanced Land Remote Sensing Systems program

As a calibrated imaging spectrometer flying at a 20 km altitude, AVIRIS may contribute to the Landsat and the Advanced Land Remote Sensing System efforts. These contributions come in the areas of: (1) on-orbit calibration, (2) specification of new spectral bands, (3) validation of algorithms, and (4) investigation of an imaging spectrometer of the Advanced Land Remote Sensing System.

Green, Robert O.↗

Extraction of auxiliary data from AVIRIS distribution tape for spectral, radiometric, and geometric quality assessment

Remotely sensed data are affected by system (sensor and platform), and scene related effects. For quantitative investigations the spectral, radiometric characteristics of the system and scene have to be known. The relevant effects and their possible influence on an image have to be specifically determined for every remote sensing system and adequate description parameters need to be updated and reported on a regular basis as they are carried out, e.g., for the AVIRIS system. It is evident that the strength of the influence of similar effects in very dependent on the accessibility of auxiliary information about such sensor systems. Degradation in a spaceborne system can normally be just reported and cannot be corrected. In contrast, an airborne sensor can be evaluated, maintained and improved periodically. Such maintenance efforts are particularly important because airborne systems are exposed to extreme and changing environments. These include tens of takeoffs and landing each year as well as extreme changes in temperature and humidity on the tarmac and in flight. For the AVIRIS system there are environmental stresses such as changes in temperature, air pressure, humidity, vibration of the platform or scene-related reasons like atmospheric conditions, and topography. The information contained in the auxiliary files included with the AVIRIS data can be used to assess these effects and compensate for them. In addition the spectral, radiometer and geometric calibration data contained in the auxiliary file are required for quantitative analysis of the data. The paper describes tools to access the auxiliary information that characterizes the AVIRIS system. These tools allow the examination of parameters that may impact the quality of the measured AVIRIS image. An example of the use of this auxiliary data was carried out with regard to a parametric geocoding approach. Emphasis is placed on the reported auxiliary information that describes the geometric character of the AVIRIS data in 1991. Results are presented using data from the AVIRIS flight #910705, run 6 and 7 of the NASA MAC Europe 1991 campaign in a test site in Central Switzerland.

Meyer, Peter↗