Engineering Papers⌕ Search

Engineering topics

Gopalsami, Nachappa

Publications and source records attributed to Gopalsami, Nachappa.

Long-Range Monostatic Remote Sensing of Geomaterial Structure Weak Vibrations

We study analytically and numerically signal sensitivity in remote sensing measurements of weak mechanical vibration of structures made of typical construction geomaterials, such as concrete. The analysis includes considerations of electromagnetic beam atmospheric absorption, reflection, scattering, diffraction and losses. Comparison is made between electromagnetic frequencies of 35GHz (Ka-band), 94GHz (W-band) and 260GHz (WR-3 waveguide band), corresponding to atmospheric transparency windows of the electromagnetic spectrum. Numerical simulations indicate that 94GHz frequency is optimal in terms of signal sensitivity and specificity for long-distance (> 1.5km) sensing of weak multi-mode vibrations.

Heifetz, Alexander↗

Interferometric millimeter wave and THz wave doppler radar

A mixerless high frequency interferometric Doppler radar system and methods has been invented, numerically validated and experimentally tested. A continuous wave source, phase modulator (e.g., a continuously oscillating reference mirror) and intensity detector are utilized. The intensity detector measures the intensity of the combined reflected Doppler signal and the modulated reference beam. Rigorous mathematics formulas have been developed to extract bot amplitude and phase from the measured intensity signal. Software in Matlab has been developed and used to extract such amplitude and phase information from the experimental data. Both amplitude and phase are calculated and the Doppler frequency signature of the object is determined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radar detection of radiation-induced ionization in air

A millimeter wave measurement system has been developed for remote detection of airborne nuclear radiation, based on electromagnetic scattering from radiation-induced ionization in air. Specifically, methods of monitoring radiation-induced ionization of air have been investigated, and the ionized air has been identified as a source of millimeter wave radar reflection, which can be utilized to determine the size and strength of a radiation source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compressive passive millimeter wave imager

A compressive scanning approach for millimeter wave imaging and sensing. A Hadamard mask is positioned to receive millimeter waves from an object to be imaged. A subset of the full set of Hadamard acquisitions is sampled. The subset is used to reconstruct an image representing the object.

42 ENGINEERING↗

Millimeter wave sensor for far-field standoff vibrometry

A millimeter wavelength (MMW) measurement system for remote detection of object characteristics and methods for detecting such characteristics. The MMW measurement system comprises a front-end and an optional signal conditioning component. The MMW front-end includes an oscillator, a transceiver portion, and an antenna for focusing a detection component comprising micrometer level wavelength electromagnetic radiation onto the object. A portion of the electromagnetic radiation reflected by the object is received by the MMW measurement system, which is indicative of a displacement of the object. The MMW system may be configured to detect micrometer level displacement of the object disposed tens of meters from the MMW measurement system. In various embodiments the object may be a natural object, including a human, and the displacement may be indicative of a heart rate and/or a respiratory function.

42 ENGINEERING↗

Surface acoustic wave probe implant for predicting epileptic seizures

A system and method for predicting and avoiding a seizure in a patient. The system and method includes use of an implanted surface acoustic wave probe and coupled RF antenna to monitor temperature of the patient's brain, critical changes in the temperature characteristic of a precursor to the seizure. The system can activate an implanted cooling unit which can avoid or minimize a seizure in the patient.

60 APPLIED LIFE SCIENCES↗

Visual Measurement of Suture Strain for Robotic Surgery

Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Passive millimeter wave spectrometer for remote detection of chemical plumes

Systems and methods for the passive measurement of spectral lines from the absorption or emission by polar molecules. The system includes mmW front-end assembly, back-end electronics, and data acquisition hardware and software was assembled. The method relates to methods for processing multi-channel radiometric data from passive mmW detection systems.

Gopalsami, Nachappa↗

Process development: Low cost, continuous nano-scale purification technology of powered carbonaceous materials for applications in electrochemical energy storage systems ELECTROCONSOLIDATON® process technology (Final CRADA Report)

Argonne, in partnership with Superior Graphite and three Ukrainian institutes, applied for, and its application was accepted for funding under the Global Initiative for Proliferation Prevention program of DOE/NNSA. Its purpose was (a) to develop carbon purification technologies for electrochemical energy storage application and (b) to build the next generation ELECTROCONSOLIDATON® system, invented by Superior Graphite, to produce special purpose parts for niche markets. Our program started in 2005 under the STCU project number P-154. In September, 2009, a 6-month extension to complete some of the outstanding work was granted, and these activities were designated under P-154a. This work concluded at the end of March in 2010, and final visits were made in June, 2010 to recognize and acknowledge the accomplishments of the group.

25 ENERGY STORAGE↗

Passive millimeter wave spectrometer for remote detection of chemical plumes

Systems and methods for the passive measurement of spectral lines from the absorption or emission by polar molecules. The system includes mmW front-end assembly, back-end electronics, and data acquisition hardware and software was assembled. The method relates to methods for processing multi-channel radiometric data from passive mmW detection systems.

Gopalsami, Nachappa↗