Engineering Papers⌕ Search

Engineering topics

Gopalsami, N

Publications and source records attributed to Gopalsami, N.

Microwave remote sensing of ionized air.

We present observations of microwave scattering from ambient room air ionized with a negative ion generator. The frequency dependence of the radar cross section of ionized air was measured from 26.5 to 40 GHz (Ka-band) in a bistatic mode with an Agilent PNA-X series (model N5245A) vector network analyzer. A detailed calibration scheme is provided to minimize the effect of the stray background field and system frequency response on the target reflection. The feasibility of detecting the microwave reflection from ionized air portends many potential applications such as remote sensing of atmospheric ionization and remote detection of radioactive ionization of air.

99 GENERAL AND MISCELLANEOUS↗

An efficient iterative algorithm for computation of scattering from dielectric objects.

We have developed an efficient iterative algorithm for electromagnetic scattering of arbitrary but relatively smooth dielectric objects. The algorithm iteratively adapts the equivalent surface currents until the electromagnetic fields inside and outside the dielectric objects match the boundary conditions. Theoretical convergence is analyzed for two examples that solve scattering of plane waves incident upon air/dielectric slabs of semi-infinite and finite thicknesses. We applied the iterative algorithm for simulation of sinusoidally-perturbed dielectric slab on one side and the method converged for such unsmooth surfaces. We next simulated the shift in radiation pattern of a 6-inch dielectric lens for different offsets of the feed antenna on the focal plane. The result is compared to that of the Geometrical Optics (GO).

36 MATERIALS SCIENCE↗

Waveguide-based ultrasonic and far-field electromagnetic sensors for downhole reservoir characterization.

This report summarizes the first year research and development effort leading to development of high-temperature sensors for enhanced geothermal systems. It covers evaluation of ultrasonic and electromagnetic (EM) techniques applied to temperature measurement and flow characterization. On temperature measurement, we have evaluated both microwave radiometry and ultrasonic techniques for temperature gradient and profile measurements. Different antenna designs are evaluated and array loop antenna design is selected for further development. We have also evaluated ultrasonic techniques for total flow characterization, which includes using speed of sound to determine flow temperature, measuring acoustic impedance to estimate fluid density, and using cross-correlation technique to determine the mass flow rate. Method to estimate the flow enthalpy is briefly discussed. At end, the need and proposed techniques to characterize the porosity and permeability of a hot dry rock resource are presented.

15 GEOTHERMAL ENERGY↗

Seizure control with thermal energy? Modeling of heat diffusivity in brain tissue and computer-based design of a prototype mini-cooler.

Automated seizure blockage is a top priority in epileptology. Lowering nervous tissue temperature below a certain level suppresses abnormal neuronal activity, an approach with certain advantages over electrical stimulation, the preferred investigational therapy for pharmacoresistant seizures. A computer model was developed to identify an efficient probe design and parameters that would allow cooling of brain tissue by no less than 21 C in 30 s, maximum. The Pennes equation and the computer code ABAQUS were used to investigate the spatiotemporal behavior of heat diffusivity in brain tissue. Arrays of distributed probes deliver sufficient thermal energy to decrease, inhomogeneously, brain tissue temperature from 37 to 20 C in 30 s and from 37 to 15 C in 60 s. Tissue disruption/loss caused by insertion of this probe is considerably less than that caused by ablative surgery. This model may be applied for the design and development of cooling devices for seizure control.

60 APPLIED LIFE SCIENCES↗

Millimeter wave detection of nuclear radiation: An alternative detection mechanism

We present a nuclear radiation detection mechanism using millimeter waves as an alternative to conventional detection. It is based on the concept that nuclear radiation causes ionization of air and that if we place a dielectric material near the radiation source, it acts as a charge accumulator of the air ions. We have found that millimeter waves can interrogate the charge cloud on the dielectric material remotely. This concept was tested with a standoff millimeter wave system by monitoring the charge levels on a cardboard tube placed in an x-ray beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REMOTE DETECTION OF RADIOACTIVE PLUMES USING MILLIMETER WAVE TECHNOLOGY

The reprocessing of spent nuclear fuel, a common method for manufacturing weapons-grade special nuclear materials, is accompanied by the release of fi ssion products trapped within the fuel. One of these fi ssion products is a radioactive isotope of Krypton (Kr-85); a pure β- emitter with a half-life of 10.72 years. Due to its chemical neutrality and relatively long half life, nearly all of the Kr-85 is released into the surrounding air during reprocessing, resulting in a concentration of Kr-85 near the source that is several orders of magnitude higher than the typical background (atmospheric) concentrations. This high concentration of Kr-85 is accompanied by a proportionately high increase in air ionization due to the release of beta radiation from Kr-85 decay. Millimeter wave (MMW) sensing technology can be used to detect the presence of Kr-85 induced plumes since a high concentration of ions in the air increases the radar cross section due to a combination of atmospheric phenomena. Possible applications for this technology include the remote sensing of reprocessing activities across national borders bolstering global anti-proliferation initiatives. The feasibility of using MMW radar technology to uniquely detect the presence of Kr-85 can be tested using commercial ion generators or sealed radioactive sources in the laboratory. In this paper we describe our work to derive an ion dispersion model that will describe the spatial distribution of ions from Kr-85 and other common lab sources. The types and energies of radiation emitted by isotopes Co-60 and Cs-137 were researched, and these parameters were incorporated into these dispersion models. Our results can be compared with the results of MMW detection experiments in order to quantify the relationship between radar cross section and air ionization as well as to further calibrate the MMW detection equipment.

Barnowski, R↗

Application of millimeter-wave radiometry for remote chemical detection.

Passive millimeter-wave systems have been used in the past to remotely map solid targets and to measure low-pressure spectral lines of stratospheric and interstellar gases; however, its application to pressure-broadened spectral line detection of industrial emissions is new. We developed a radiative transfer model to determine feasibility and system requirements for passive millimeter-wave spectral detection of terrestrial gases. We designed and built a Dicke-switched multispectral radiometer in the 146-154-GHz band to detect nitric oxide (NO), a prototypical gas of nuclear fuel processing operations. We first tested the spectral detection capability of the radiometer in the laboratory using a gas cell and then field tested it at the Nevada test site at a distance of 600 m from a stack that released hot plumes of NO and air. With features such as Dicke-switched integration, frequent online calibration, and spectral baseline subtraction, we demonstrated the feasibility of remote detection of terrestrial gases by a ground-based radiometer.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emission of coherent THz-radiation from superconductors.

Compact solid-state sources of terahertz (THz) radiation are being sought for sensing, imaging, and spectroscopy applications across the physical and biological sciences. We demonstrate that coherent continuous-wave THz radiation of sizable power can be extracted from intrinsic Josephson junctions in the layered high-temperature superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8}. In analogy to a laser cavity, the excitation of an electromagnetic cavity resonance inside the sample generates a macroscopic coherent state in which a large number of junctions are synchronized to oscillate in phase. The emission power is found to increase as the square of the number of junctions reaching values of 0.5 microwatt at frequencies up to 0.85 THz, and persists up to 50 kelvin. These results should stimulate the development of superconducting compact sources of THz radiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗