Engineering Papers⌕ Search

Engineering topics

Gopalakrishnan, Pradeep

Publications and source records attributed to Gopalakrishnan, Pradeep.

Development of parallel DEM for the open source code MFIX

The paper presents the development of a parallel Discrete Element Method (DEM) solver for the open source code, Multiphase Flow with Interphase eXchange (MFIX) based on the domain decomposition method. The performance of the code was evaluated by simulating a bubbling fluidized bed with 2.5 million particles. The DEM solver shows strong scalability up to 256 processors with an efficiency of 81%. Further, to analyze weak scaling, the static height of the fluidized bed was increased to hold 5 and 10 million particles. The results show that global communication cost increases with problem size while the computational cost remains constant. Further, the effects of static bed height on the bubble hydrodynamics and mixing characteristics are analyzed.

42 ENGINEERING↗

CFD-DEM study of effect of bed thickness for bubbling fluidized beds

The effect of bed thickness in rectangular fluidized beds is investigated through the CFD–DEM simulations of small-scale systems. Numerical results are compared for bubbling fluidized beds of various bed thicknesses with respect to particle packing, bed expansion, bubble behavior, solids velocities, and particle kinetic energy. Good two-dimensional (2D) flow behavior is observed in the bed having a thickness of up to 20 particle diameters. However, a strong three-dimensional (3D) flow behavior is observed in beds with a thickness of 40 particle diameters, indicating the transition from 2D flow to 3D flow within the range of 20–40 particle diameters. Comparison of velocity profiles near the walls and at the center of the bed shows significant impact of the front and back walls on the flow hydrodynamics of pseudo-2D fluidized beds. Hence, for quantitative comparison with experiments in pseudo-2D columns, the effect of walls has to be accounted for in numerical simulations.

42 ENGINEERING↗

Beam Heating of Samples: Modeling and Verification

Energy absorbed from the X-ray beam by the sample requires cooling by forced convection (i.e. cryostream) to minimize temperature increase and the damage caused to the sample by the X-ray heating. In this presentation we will first review the current theoretical models and recent studies in the literature, which predict the sample temperature rise for a given set of beam parameters. It should be noted that a common weakness of these previous studies is that none of them provide actual experimental confirmation. This situation is now remedied in our investigation where the problem of x-ray sample heating is taken up once more. We have theoretically investigated, and at the same time, in addition to the numerical computations, performed experiments to validate the predictions. We have modeled, analyzed and experimentally tested the temperature rise of a 1 mm diameter glass sphere (sample surrogate) exposed to an intense synchrotron X-ray beam, while it is being cooled in a uniform flow of nitrogen gas. The heat transfer, including external convection and internal heat conduction was theoretically modeled using CFD to predict the temperature variation in the sphere during cooling and while it was subjected to an undulator (ID sector 19) X-ray beam at the APS. The surface temperature of the sphere during the X-ray beam heating was measured using the infrared camera measurement technique described in a previous talk. The temperatures from the numerical predictions and experimental measurements are compared and discussed. Additional results are reported for the two different sphere sizes and for two different supporting pin orientations.

Kazmierczak, Michael↗