Hotspot Endurance Of Solar-Cell Modules

Procedure for evaluating modules for use with concentrators now available. Solar simulator illuminates photovoltaic cells through Fresnel lens of concentrator module. Module and test cells inspected visually at 24-h intervals during test and again when test completed. After test, electrical characteristics of module measured for comparison with pretest characteristics.

Gonzalez, C. C.

Concentrator hot-spot testing, phase 1

Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator module hot-spot qualification test is the test developed for flat-plate modules, issues, such as providing cell illumination, introduce additional complexities into the testing procedure. The same general guidelines apply for protecting concentrator modules from hot-spot stressing as apply to flat-plate modules. Therefore, recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. In addition, a new method for determining the cell temperature in the laboratory or in the field is discussed.

Gonzalez, C. C.

Hot-spot qualification testing of concentrator modules

Results of a study to determine the hot-spot susceptibility of concentrator cells, to provide a hot-spot qualification test for concentrator modules, and to provide guidelines for reducing hot-spot susceptibility are presented. Hot-spot heating occurs in a photovoltaic module when the short-circuit current of a cell is lower than the string operating current, forcing the cell into reverse bias with a concurrent power dissipation. Although the basis for the concentrator-module hot-spot qualification test is the test developed for flat-plate modules, issues such as providing cell illumination introduce additional complexities into the testing procedure. The results indicate that the same general guidelines apply to protecting concentrator modules from hot-spot stressing as apply to flat-plate modules, and recommendations are made on the number of bypass diodes required per given number of series cells per module or source circuit. A method for determining the cell temperature in the laboratory or in the field is discussed.

Gonzalez, C. C.

UV-T-RH combined environmental testing

A combined environmental aging chamber was developed at the Jet Propulsion Laboratory (JPL). The chamber has an ultraviolet (UV) light source that can be varied between 1 to 2 suns, temperature control from -40 to +175 C, and adjustable humidity. Results from two initial aging experiments (Tedlar and amorphous silicon colar cells) were presented.

Gonzalez, C. C.

Hot-spot heating susceptibility due to reverse bias operating conditions

Because of field experience (indicating that cell and module degradation could occur as a result of hot spot heating), a laboratory test was developed at JPL to determine hot spot susceptibility of modules. The initial hot spot testing work at JPL formed a foundation for the test development. Test parameters are selected as follows. For high shunt resistance cells, the applied back bias test current is set equal to the test cell current at maximum power. For low shunt resistance cells, the test current is set equal to the cell short circuit current. The shadow level is selected to conform to that which would lead to maximum back bias voltage under the appropriate test current level. The test voltage is determined by the bypass diode frequency. The test conditions are meant to simulate the thermal boundary conditions for 100 mW/sq cm, 40C ambient environment. The test lasts 100 hours. A key assumption made during the development of the test is that no current imbalance results from the connecting of multiparallel cell strings. Therefore, the test as originally developed was applicable for single string case only.

Gonzalez, C. C.

Amorphous-silicon module hot-spot testing

Hot spot heating occurs when cell short-circuit current is lower than string operating current. Amorphous cell hot spot are tested to develop the techniques required for performing reverse bias testing of amorphous cells. Also, to quantify the response of amorphous cells to reverse biasing. Guidelines are developed from testing for reducing hot spot susceptibility of amorphous modules and to develop a qualification test for hot spot testing of amorphous modules. It is concluded that amorphous cells undergo hot spot heating similarly to crystalline cells. Comparison of results obtained with submodules versus actual modules indicate heating levels lower in actual modules. Module design must address hot spot testing and hot spot qualification test conducted on modules showed no instabilities and minor cell erosion.

Gonzalez, C. C.

Maximum Outputs of Solar Photovoltaic Arrays

Report presents electrical data for solar photovoltaic arrays operating at different locations in United States. Data useful in designing power-conditioners for matching output of array to load.

Ross, R. G., Jr.

Assessing the Performance of Solar Arrays

Selected environmental conditions more effective than traditional parameters. Report analyzes selection of reference criteria for comparing performances of photovoltaic arrays.

Ross, R. G., Jr.

Testing for Solar-Array Hotspots

Laboratory procedure developed for evaluting hot-spot endurance of photovoltaic modules under field-service conditions. Procedures used for qualification testing of modules.

Gonzalez, C. C.

Predicting Solar Deficits

Statistical method uses available long term solar irradiance data at selected sites in United States to predict probable deviations from long term monthly averages. Technique useful in sizing solar collectors and backup storage systems to cover solar deficits.

Ross, R. G., Jr.

Predicting photothermal field performance

Photothermal field performance in flat plate solar collectors was predicted. An analytical model which incorporates the measured dependency between transmittance loss and UV and temperature exposure levels was developed. The model uses SOLMET weather data extrapolated to 30 years for various sites and module mounting configurations. It is concluded that the temperature is the key to photothermally induced transmittance loss. The sensitivity of transmittance loss to UV level is nonlinear with minimum in curve near one sun. The ethylene vinyl acetate (EVA) results are consistent with 30 year life allocation.

Gonzalez, C. C.

Determination of hot-spot susceptibility of multistring photovoltaic modules in a central-station application

Part of the effort of the Jet Propulsion Laboratory (JPL) Flat-Plate Solar Array Project (FSA) includes a program to improve module and array reliability. A collaborative activity with industry dealing with the problem of hot-spot heating due to the shadowing of photovoltaic cells in modules and arrays containing several paralleled cell strings is described. The use of multiparallel strings in large central-station arrays introduces the likelihood of unequal current sharing and increased heating levels. Test results that relate power dissipated, current imbalance, cross-strapping frequency, and shadow configuration to hot-spot heating levels are presented. Recommendations for circuit design configurations appropriate to central-station applications that reduce the risk of hot-spot problems are offered. Guidelines are provided for developing hot-spot tests for arrays when current imbalance is a threat.

Gonzalez, C. C.

Hot-spot heating in central-station arrays

Hot spot tests performed on the Sacramento Municipal Utility District (SMUD) verificaton array show that current imbalance occurs, resulting in significant hot spot heating. One cause of current imbalance is differences in the average shunt resistances of parallel cell strings due to cell shunt resistance variations. In depth hot spot tests are performed on the verification array with bypass diodes. The tests had several objectives: (1) a comparison of hot spot temperatures achieved under field conditions with those obtained with the present laboratory hot spot test using similar modules; (2) an assessment of current imbalance versus cross tie frequency; and (3) an assessment of different shadow patterns and shadow densities. Instrumented modules are used to vary the number of cross ties and to measure the test-cell current and back-bias voltage. The widths, lengths, and densities of the shadows are varied to maximize the back bias voltage at maximum power current. An infrared camera is used to indicate the existence of hot spots and estimate temperature increases in conjunction with thermocouples. The results of these hot spot tests indicate a sensitivity of back bias heating to the shadow size (amount of cell coverage) and density.

Gonzalez, C. C.

Photovoltaic array: Power conditioner interface characteristics

The electrical output (power, current, and voltage) of flat plate solar arrays changes constantly, due primarily to changes in cell temperature and irradiance level. As a result, array loads such as dc-to-ac power conditioners must be capable of accommodating widely varying input levels while maintaining operation at or near the maximum power point of the array. The array operating characteristics and extreme output limits necessary for the systematic design of array load interfaces under a wide variety of climatic conditions are studied. A number of interface parameters are examined, including optimum operating voltage, voltage energy, maximum power and current limits, and maximum open circuit voltage. The effect of array degradation and I-V curve fill factor or the array power conditioner interface is also discussed. Results are presented as normalized ratios of power conditioner parameters to array parameters, making the results universally applicable to a wide variety of system sizes, sites, and operating modes.

Gonzalez, C. C.

A technique for determining solar irradiance deficits

An analytic technique which determines the variation of solar irradiance from long term averages is presented. The technique involves computer-assisted data reduction techniques, and was designed to improve system reliability by determining the amount of storage capability required to supplement a baseline system. Variations in time intervals of up to 60 days can be determined, and 10 years of data collection are reviewed. The technique involves first calculating average monthly irradiance values, then examining the average irradiance deviation over time intervals. The calculation procedure is clarified by determining solar energy level probabilities and the long term solar energy deviation (achieved by repeatedly integrating actual irradiance figures). It is found that a 15% increase in collector area and the addition of energy storage or backup are essential contributions to achieving cost-effectiveness. In addition, one to seven no-sun day storage capacities are required to accommodate weather caused deficits.

Gonzalez, C. C.

Characterization of the electrical output of flat-plate photovoltaic arrays

The electric output of flat-plate photovoltaic arrays changes constantly, due primarily to changes in cell temperature and irradiance level. As a result, array loads such as direct-current to alternating-current power conditioners must be able to accommodate widely varying input levels, while maintaining operation at or near the array maximum power point.The results of an extensive computer simulation study that was used to define the parameters necessary for the systematic design of array/power-conditioner interfaces are presented as normalized ratios of power-conditioner parameters to array parameters, to make the results universally applicable to a wide variety of system sizes, sites, and operating modes. The advantages of maximum power tracking and a technique for computing average annual power-conditioner efficiency are discussed.

Gonzalez, C. C.

Photovoltaic module hot spot durability design and test methods

As part of the Jet Propulsion Laboratory's Low-Cost Solar Array Project, the susceptibility of fat-plate modules to hot-spot problems is investigated. Hot-spot problems arise in modules when the cells become back-biased and operate in the negative-voltage quadrant, as a result of short-circuit current mismatch, cell cracking or shadowing. The details of a qualification test for determining the capability of modules of surviving field hot-spot problems and typical results of this test are presented. In addition, recommended circuit-design techniques for improving the module and array reliability with respect to hot-spot problems are presented.

Arnett, J. C.

Quarantine constraints as applied to satellites

Plans for unmanned missions to planets beyond Mars in the 1970s include satellite encounters. Recently published observations of data for Titan, a satellite of Saturn, indicate that conditions may be hospitable for the growth of microorganisms. Therefore, the problem of satisfying possible quarantine constraints for outer planet satellites was investigated. This involved determining the probability of impacting a satellite of Jupiter or Saturn by a spacecraft for a planned satellite encounter during an outer planet mission. Mathematical procedures were formulated which determine the areas in the aim-plane that would result in trajectories that impact the satellite and provide a technique for numerically integrating the navigation error function over the impact area to obtain impact probabilities. The results indicate which of the planned spacecraft trajectory correction maneuvers are most critical in terms of satellite quarantine violation.

Hoffman, A. R.