Fuel Debris Monitoring Collaboration and Experiences in Criticality Monitoring

Fukushima Daiichi fuel debris removal provides technical challenges and opportunities for the international criticality safety community. The US DOE-NCSP (Nuclear Criticality Safety Program) and France (IRSN) will support 1F fuel debris efforts through collaboration on real-time criticality monitoring. This work will describe a collaboration that is starting soon and will also describe previous efforts associated with criticality experiments and neutron analysis of unknown systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verifying MCNP Models of the TEX High 240 Plutonium Benchmark

Computational modeling programs are invaluable tools that allow us to understand systems, safely develop new processes, and make reliable predictions about future designs. However, the effectiveness of these codes is limited by the degree to which their parameters match the real world. In the field of nuclear engineering, cross section data is one of these vital parameters. Accurate cross section data on important fissile and fissionable isotopes promotes the design of safer and more efficient fabrication, transportation, storage, and stockpiling of nuclear fuel. Unfortunately, there are knowledge gaps in data on key isotopes. In 2011, a multinational meeting hosted by the US Department of Energy Nuclear Criticality Safety Program ranked the priority of certain cross section data needs. In response, Lawrence Livermore National Lab (LLNL) designed the Thermal and Epithermal eXperiment (TEX) series of benchmark experiments. Benchmark experiments are used to validate current cross section data. They validate data by comparing the results of an actual experiment to the predicted results from a computational model. The data a benchmark applies to depends on the isotope and energy range the experiment’s neutron multiplication factor ( k eff ) is most sensitive to. The development and testing of the TEX High 240 Plutonium Benchmark will help validate 240 Pu cross section data. The configuration and materials of this benchmark are designed to be most sensitive to 240 Pu's intermediate energy range (from 0.625 ev to 100 keV ). MCNP® models of the assembly have been developed by LLNL and the results have been written in the final design report. In order for the discrepancies between benchmark models and experiments to be attributed to cross section inaccuracies, the accuracy of the models needs to be verified. The goal of this project is to verify of the results of LLNL's modeling by creating a new set of MCNP models and comparing the results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Criticality Experiments Research Center Futures: A Report of a Workshop held September 6-9, 2022, Los Alamos, NM, November, 2022

Experiments and training with critical assemblies and fissionable material (at or near the critical state) that explore reactivity phenomena are central to a number of national security challenges. From fission energy to nuclear weapons to a broad suite of scientific challenges, it is clear that additional capacity and capability are needed. The National Criticality Experiments Research Center (NCERC) marked 10 years of operations in 2021. This anniversary was an opportune time to celebrate our successes and progress, and to evaluate the remaining and emergent challenges. Against this backdrop, a workshop of approximately 140 national and international leaders in nuclear research was convened in Los Alamos, New Mexico to explore “NCERC Futures.” Therefore, the present workshop focused specifically on needed capabilities and tools to meet the research challenges in eight topical mission areas served by NCERC. As each Topical Group summarized their discussions in the out brief, it was recognized that key challenges could be met through enabling infrastructure investments and new critical assemblies. Enabling infrastructure includes staffing, additional space/buildings, developing an agile bounding safety basis, the ability to keep pace with technological advances in detectors and data acquisition systems (allowing use of those with Bluetooth™ and similar technologies), an expanded set of materials options (especially plutonium), a “Plug and Play” design and implementation mindset, and a facility that enabled free-field measurements. The new critical assemblies that were identified as having the most impact were a bare plutonium (Pu) Critical Assembly, a Horizontal Split Table (HST), a Super Comet, and a Uranium Solution Burst Assembly. NECRC is a unique, one-of-a-kind facility in the United States. If all the improvements were to be made, NCERC would enable the United States and its partners to address many important research questions related to criticality. These include but are not limited to: (1) Covering the entire neutron energy spectrum for both highly enriched uranium (HEU) and Pu in configurations for virtually all conceivable applications; (2) Performing multi-physics solution experiments and irradiations with a Uranium Solution Burst Assembly, which more closely resembles actual criticality accidents; (3) Conducting free-field experiments to make basic fission physics measurements and much cleaner benchmarks with various experimental observables; and (4) Providing more training classes and more experiments annually at greater cost efficiency enabled by additional buildings and machines and an agile, bounding, risk-balanced Safety Basis. In the end, workshop attendees enthusiastically concluded that NCERC Futures are bright and the workshop helped to identify a roadmap of capability gaps that need to be addressed. This report documents the results of those efforts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER-517: Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK)

Nuclear criticality experiments are essential to the validation of nuclear data used in simulation software. The quality of nuclear data becomes paramount as simulation software becomes more relied upon for criticality safety studies and designs of nuclear systems. To improve the quality of nuclear data, experimenters can design critical experiments that are sensitive to isotope reaction pairs in materials of interest. The efforts conducted by the Organisation for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA) Working Party on Nuclear Criticality Safety (WPNCS) Subgroup 8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks (SG8) to categorize benchmarks according to their usefulness for nuclear data validation have been of great importance. Based on the OECD studies benchmark experiments included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook are concisely used by nuclear data evaluators, criticality safety engineers and others to validate nuclear data and simulation results. A lack of benchmarks sensitive to molybdenum in the (ICSBEP), particularly in the intermediate range, was noted by Los Alamos National Laboratory (LANL), the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN), and Y-12 National Security Site prompting them to submit a joint integral experiment request to the Nuclear Criticality Safety Program (NCSP) in 2019. The request included both HEU and Plutonium systems in order to validate differential nuclear data focusing on the intermediate energy range but also includes thermal and fast configurations. This document represents the preliminary design work for a series of molybdenum integral experiments known as Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

IER 555: Godiva Benchmark Update CED-2 (Final Design Report)

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluation of the Godiva IV critical assembly, HEU-MET-FAST-086: GODIVA-IV DELAYED-CRITICAL EXPERIMENTS (HMF-086), was completed by Russ Mosteller. Five critical experiment configurations performed at the Los Alamos National Laboratory (LANL) Technical Area (TA)-18 were evaluated as acceptable benchmark cases. The five cases consist of four delayed critical configurations which differ in control rod positions and one prompt critical configuration. All cases calculated a lower $k_{eff}$ than measured by experiment. This data is referred to as the TA-18 Godiva IV benchmark in this report. In 2005, Godiva IV was disassembled for relocation to the Nevada Test Site (NTS), now Nevada National Security Site (NNSS), at the National Criticality Experiments Research Center (NCERC). Following the disassembly and subsequent reassembly and startup of Godiva IV at NCERC, additional information about the Godiva IV components was obtained. An errata note was added to the HMF-086 evaluation in the ICSBEP handbook to provide this new information until a revision to the benchmark evaluation could be performed. In addition to those corrections, there are differences between the Godiva IV assembly at TA-18 and the Godiva IV assembly at NCERC. These differences include both assembly-specific differences (differences in the safety block gap, differences in the control rod positions, a new NCERC Top Hat and contamination shield) as well as environmental differences, such as the size and shape of the experimental building where the assembly is located. An additional model with similar cases, referred to as the NCERC Godiva IV benchmark in this report, will be added to the revised HMF-086 to capture these additional differences. This will provide the best benchmark model of Godiva for use by those performing experiments at NCERC. The IER 555 CED-2 report documents the information that will be updated in the HMF-086 revision, both the corrections to the TA-18 Godiva IV benchmark and the subsequent changes to create a NCERC Godiva IV benchmark. It describes the measurements that will be performed for cases similar to those performed at TA-18. It also describes measurements that will be included in the evaluation as additional data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 557: Godiva Pulse Repeatability and Characterization (CED-3A Report)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. Godiva IV is proposed as the radiation source for IER 498: Design a Shielding Benchmark with a Metal Critical Source. IER 498 proposes a two-burst method to determine the performance of shielding samples, comparing the transmission of the source radiation to detectors with and without a shielding sample present. This eliminates the need for an absolute calibration and allows many uncertainties to cancel. However, the source term variability must be low compared to other sources of experimental uncertainty to ensure the overall uncertainty meets acceptable levels to provide useful measurements. The primary goal of this experiment is to quantify the source term variability, or reproducibility, of Godiva bursts, focusing on the 70 °C bursts planned for IER 498 measurements. Discussions during IER 498 noted that a number of bursts (on the order of six to ten) as identical as possible would be performed and that a 5-7% standard deviation in source intensity would be acceptable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated Godiva-IV Benchmark Preview

A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused keff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.A note of errata prepended to the Godiva-IV delayed-critical benchmark (HEU-MET-FAST- 086) identifies two corrections to be made to the model: The glory hole in the spindle should be made larger, and the height of the safety block should be made smaller (and therefore its density made larger). In addition, the safety block at its full-in position is closer to the inner subassembly plate than was modeled in the benchmark. These changes have been made to HEU-MET-FAST-086 Case 4 in order to estimate the effect on $\kappa$ eff and on the neutron flux spectrum. Using smaller separation, a smaller safety block, and a larger glory hole caused $\kappa$ eff to increase by 453 ± 1 pcm from the benchmark. The latest nuclear data, ENDF/B-VIII.0, have also been used, causing $\kappa$ eff to increase another 37 ± 1 pcm. Flux spectra were compared in a modeled fission foil (near the center of Godiva-IV in the glory hole) and at three external (point) detectors. Within the fission foil, using ENDF/B-VIII.0 induced changes in the flux spectrum similar in size to the changes due to using smaller separation, a smaller safety block, and a larger glory hole. At the detectors, using ENDF/B- VIII.0 induced changes in the flux spectrum much larger than those due to changing the model. In other words, the corrections to the benchmark model cause a large increase in $\kappa$ eff , but the changes to the neutron flux spectrum are small compared to those caused by using the latest nuclear data. This study presents a preview of results expected during the reevaluation of the Godiva IV benchmark, but it is not a substitute for the full reevaluation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Criticality Experiments Research Center (NCERC) Recent Measurements and Capabilities [Slides]

The National Criticality Experiments Research Center (NCERC) is operated by Los Alamos National Laboratory and has four critical assemblies (Including Godiva, which can be operated above prompt critical). Subcritical measurements are also performed. NCERC is the only general-purpose critical experiments facility in the US and is one of only a few that remain operational throughout the world.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Special Issue of Nuclear Science and Engineering celebrates the Tenth Anniversary of Operations at NCERC

The National Criticality Experiments Research Center (NCERC) is a general-purpose critical experiment facility, the only one in the US and one a few that remain operational throughout the world. NCERC is located at the Nevada National Security Site (NNSS), formerly known as the Nevada Test Site, and is operated by Los Alamos National Laboratory (LANL). This year, NCERC celebrated its 10th year of operation. To commemorate the first ten years of operations and experiments, a special issue of Nuclear Science and Engineering was prepared with papers focusing on each of the four critical assemblies and one on Radiation Test Object (RTO) measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CERBERUS: CEDT Phase-1 Preliminary Design for Cu Critical Experiment

The goal of the Critical Experiment Reflected By copper to bEtteR Understand Scattering [CERBERUS] is to design a critical experiment that maximizes sensitivities to Cu reactions, particularly in the intermediate energy region (0.625 eV – 100 keV). Despite the number of experiments evaluated in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook1, there is still a gap of benchmarks sensitive to neutrons in the intermediate energy region. Of the ICSBEP benchmarks sensitive to neutrons in the intermediate energy region, very few are also sensitive to Cu in that region. One of the primary intermediate energy benchmark evaluations is the ZEUS series, which uses a Cu reflector. However, concerns have been brought up about the nuclear data associated with Cu scattering in the reflector. Improving Cu nuclear data is important outside of the ZEUS series, because it is present in many bronze and aluminum alloys, which are used in various nuclear operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NCERC Capabilities [Slides]

NCERC is our nation’s only generalpurpose critical experiments facility and is one of only a few that remain operational throughout the world. The mission of the National Criticality Experiments Research Center (NCERC) is to conduct experiments and training with critical assemblies and fissionable material at or near criticality in order to explore reactivity phenomena, and to operate the assemblies in the regions from subcritical through delayed critical. One critical assembly, Godiva-IV, is designed to operate above prompt critical.