Engineering Papers⌕ Search

Engineering topics

Gloeckler, G.

Publications and source records attributed to Gloeckler, G..

At least 253 records · Page 14

Direct observations of the charge states of low energy solar particles

The charge states of carbon and oxygen of solar origin have been measured directly in interplanetary space. At 100 keV per nucleon the C(+5)/C(+6) and O(+7)/O(+8) ratios are 1.8 and 1.6, respectively. Abundance ratios of low energy heavy nuclei to He are found which are significantly larger than the corresponding photospheric values. The enhancement of O/He is 35, and both Si/He and Fe/He are overabundant by a factor of 100. To explain these observations a mechanism is proposed which first preferentially accelerates heavy ions and is followed by either storage of these ions in the coronal regions or strong adiabatic deceleration.

Gloeckler, G.↗

Measurement of elemental abundance of very low energy solar cosmic rays

Heavy interplanetary particles (Z from 3 to 30) have been observed during a solar flare period between October 29 and November 4, 1972. The nuclear abundance has been determined by a two parameter analysis of a thin window proportional counter - solid state detector device aboard the Explorer 47 (IMP-7) satellite. Energy spectra are given for C, O and Fe. The elemental abundance relative to oxygen is determined for carbon, neon, magnesium, silicon and the iron group in the energy range 0.62 to 6.9 MeV/nucleon. For the Fe/O ratio no energy dependence could be observed within the error limits.

Hovestadt, D.↗

Direct Observations of the Charge States of Low Energy Solar Particles

The charge states of carbon and oxygen of solar origin were measured directly in interplanetary space. At 100 keV per nucleon the C(+5)/C(+6) and O(+7)/O(+8) ratios are 1.8 and 1.6 respectively. It was found that the abundance ratios of low energy heavy nuclei to He is significantly larger than corresponding photospheric values: the enhancement of O/He is 35 and both Si/He and Fe/He are overabundant by a factor of 100. To explain these observations a mechanism is proposed which first preferentially accelerates heavy ions and is followed by either storage of these ions in the coronal regions or strong adiabatic deceleration.

Gloeckler, G.↗

Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

A 6500 sq cm-ster cosmic ray detector consisting of twelve gas counter trays sandwiched between two large area circular scintillation counters was flown from Palestine, Texas in November of 1972 to study the composition of primary particles 1.5 GeV/nucleon in the charge range 3 to 30. For each analyzed event, a recording was made of (1) the particle trajectory using four 20 wire proportional counter trays, (2) the energy loss in each of the solid counters, and (3) the dE/dx losses in each of the twelve gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

Lheureux, J.↗

Intensity Oscillation of Low Energy Solar Particles Observed on the IMP 7 Satellite

Solar flare particles in the energy range from 125 to 160 KeV per charge were detected and analyzed by an electrostatic deflection vs. energy instrument on board the Explorer 47 (IMP 7) satellite. A harmonic analysis of the counting rates shows that frequently, the fluctuation of the particle flux can be approximately represented by N(t) = f(t)sin 2 pi nu t where f(t) is a smoothly varying function of t. The oscillation frequency nu varies from flare to flare and is of the order of 2 x .001/sec. The physical implications of the finding are discussed.

Fan, C. Y.↗

Measurement of Elemental Abundance of Very Low Energy Solar Cosmic Rays

Heavy interplanetary particles were observed during a solar flare period between October 29 and November 4, 1972. The nuclear abundance was determined by a two parameter analysis (dE/dx vs E technique) of a thin window proportional counter - solid state detector device aboard the Explorer 47 (IMP-7) satellite. Energy spectra are given for C, O and Fe. The elemental abundance relative to oxygen is determined for carbon, neon, magnesium, silicon and the iron group in the energy range 0.62 to 6.9 MeV/nucleon. For the Fe/O ratio no energy dependence could be observed within the error limits.

Hovestadt, D.↗

Differential energy spectra of low energy (less than 8.5 MeV per nucleon) heavy cosmic rays during solar quiet times

Explorer 47 satellite observations of carbon, oxygen, and heavier nuclei differential energy spectra below 8.5 MeV/nucleon are presented for solar quiet time periods. A dE/dx vs E method for particle identification and energy determination was used. The instrumentation telescope included an isobutane proportional counter, a surface barrier Si detector, and a cylindrical plastic scintillator anticoincidence shield. The observations were performed outside the bow-shock and in the ecliptic plane. Results show an anisotropy of about 25% at 22 degrees west of the sun with a C/O ratio of 0.5 supporting a solar origin. The low energy portions of the C and O spectra have steep negative slopes, and the corresponding power law is given. Peculiarities in the O spectrum are discussed.

Hovestadt, D.↗

Production and propagation of particles with A greater than 81 in the Galaxy.

A detailed mathematical model is developed to describe the transformation of the charge composition of superheavy (A greater than 81) cosmic rays by spallation on interstellar hydrogen in the Galaxy. If one takes a single source which suddenly injects particles with an r-process charge spectrum t years in the past, the calculated relative abundance ratios in four atomic mass groups are consistent with measured values for t equal to 250,000 years. We further conclude that for any initial source distribution the upper limit on t is 1 m.y.

Kaiser, T. B.↗