Engineering PapersSearch

Engineering topics

Gleason, J.

Publications and source records attributed to Gleason, J..

Proposed LISA Telescope Design

The Laser Interferometer Space Antenna (LISA), requires high precision displacement measurement between widely spaced pairs of freely floating test masses. We describe a proposed design for the optical telescopes that form an essential part of the laser heterodyne interferometry measurement system and discuss how the design and implementation will address the unique challenges of this specialized application.

Livas, J.

Current Applications of OMI Tropospheric NO2 Data for Air Quality and a Look to the Future

Ozone Monitoring Instrument (OMI) Tropospheric NO2 products are being used to enhance the ability to monitor changes in NO2 air quality, update emission inventories, and evaluate regional air quality models. Trends in tropospheric column NO2 have been examined over the eastern United States in relation to emissions changes mandated by regulatory actions. Decreases of 20 to 40 percent over the period 2005 to 2008 were noted, largely in response to major emission reductions at power plants. The OMI data have been used to identify regions in which the opposite trend has been found. We have also used OMI NO2 in efforts to improve emission inventories for NOx emissions from soil. Lightning NOx emissions have been added to CMAQ, the US Environmental Protection Agency's regional air quality model. Evaluation of the resulting NO2 columns in the model is being conducted using the OMI NO2 observations. Community Multiscale Air Quality (CMAQ) together with the OMI NO2 data comprise a valuable tool for monitoring and predicting air quality. Looking to the future, we expect that the combination of Global Ozone Monitoring Experiment-2 (GOME-2) (morning) and OMI (afternoon) data sets obtained through use of the same retrieval algorithms will substantially increase the possibility of successful integration of satellite information into regional air quality forecast models. Farther down the road, we anticipate the Geostationary Coastal and Air Pollution Events (GEO-CAPE) platform to supply data possibly on an hourly basis, allowing much more comprehensive analysis of air quality from space.

Pickering, Kenneth E.

The 'Weekend Effect' in Tropospheric NO2 Seen from the Ozone Monitoring Instrument

The Ozone Monitoring Instrument has gathered daily global data on NO2 and other atmospheric trace gases since its launch on the EOS Aura satellite in 2004. The large accumulated data set makes it possible to monitor changes of both meteorological and anthropogenic origin in tropospheric NOz amounts. In particular, averages on time scales on the order of a year show a distinct 'weekend effect' in NO2 variation, with smaller NO2 amounts seen on Saturday and/or Sunday than on the remaining weekdays. Using the OMI NO2 Standard Product (SP), we examine this effect in relation to geopolitical boundaries and investigate implications for identifying sources. We also use the SP data to find evidence for other short-term anthropogenic changes in NO2 emissions over heavily polluted regions including the United States, Europe and China.

Bucsela, E.

Exploration of OMI Products for Air Quality Applications Through Comparisons with Models and Observations

The Ozone Monitoring Instrument (OMI) on board NASA s Aura satellite was launched in July 2004, and is now providing daily global observations of total column ozone, NO2, and SO2, as well as aerosol information. Algorithms have also been developed to produce daily tropospheric ozone and NO2 products. The tropospheric ozone product reported here is a tropospheric residual computed through use of Aura Microwave Limb Sounder (MLS) ozone profile data to quantify stratospheric ozone. We are investigating the applicability of OMI products for use in air quality modeling, forecasting, and analysis. These investigations include comparison of the OMI tropospheric O3 and NO2 products with global and regional models and with lower tropospheric aircraft observations. Large-scale transport of pollution seen in the OM1 tropospheric O3 data is compared with output from NASA's Global Modeling Initiative global chemistry and transport model. On the regional scale we compare the OMI tropospheric O3 and NO2 with fields from the National Oceanic and Atmospheric Administration and Environmental Protection Agency (NOAA/EPA) operational Eta/CMAQ air quality forecasting model over the eastern United States. This 12-km horizontal resolution model output is roughly of equivalent resolution to the OMI pixel data. Correlation analysis between lower tropospheric aircraft O3 profile data taken by the University of Maryland over the Mid-Atlantic States and OMI tropospheric column mean volume mixing ratio for O3 will be presented. These aircraft data are representative of the lowest 3 kilometers of the atmosphere, the region in which much of the locally-generated and regionally-transported ozone exists.

Pickering, K. E.

GOME Total Ozone and Calibration Error Derived Usign Version 8 TOMS Algorithm

The Global Ozone Monitoring Experiment (GOME) is a hyper-spectral satellite instrument measuring the ultraviolet backscatter at relatively high spectral resolution. GOME radiances have been slit averaged to emulate measurements of the Total Ozone Mapping Spectrometer (TOMS) made at discrete wavelengths and processed using the new TOMS Version 8 Ozone Algorithm. Compared to Differential Optical Absorption Spectroscopy (DOAS) techniques based on local structure in the Huggins Bands, the TOMS uses differential absorption between a pair of wavelengths including the local stiucture as well as the background continuum. This makes the TOMS Algorithm more sensitive to ozone, but it also makes the algorithm more sensitive to instrument calibration errors. While calibration adjustments are not needed for the fitting techniques like the DOAS employed in GOME algorithms, some adjustment is necessary when applying the TOMS Algorithm to GOME. Using spectral discrimination at near ultraviolet wavelength channels unabsorbed by ozone, the GOME wavelength dependent calibration drift is estimated and then checked using pair justification. In addition, the day one calibration offset is estimated based on the residuals of the Version 8 TOMS Algorithm. The estimated drift in the 2b detector of GOME is small through the first four years and then increases rapidly to +5% in normalized radiance at 331 nm relative to 385 nm by mid 2000. The lb detector appears to be quite well behaved throughout this time period.

Gleason, J.

Total Ozone from the Ozone Monitoring System (OMI) using TOMS and DOAS Methods

The Ozone Monitoring Instrument (OMI) is the Dutch-Finnish contribution to NASA's EOS-Aura satellite scheduled for launch in January 2004. OMI is an imaging spectrometer that will measure the back-scattered Solar radiance in the wavelength range of 270 to 500 nm. The instrument provides near global coverage in one day with a spatial resolution of 13x24 square kilometers. OMI is a new instrument, with a heritage from TOMS, SBW, GOME, GOMOS and SCIAMACHY. OMI'S unique capabilities for measuring important trace gases and aerosols with a small footprint and daily global coverage, in conjunction with the other Aura instruments, will make a major contribution to our understanding of stratospheric and tropospheric chemistry and climate change. OMI will provide data continuity with the 23-year ozone record of TOMS. There are three ozone products planned for OMI: total column ozone, ozone profile and tropospheric column ozone. We are developing two different algorithms for total column ozone: one similar to the algorithm currently being used to process the TOMS data, and the other an improved version of the differential optical absorption spectroscopy (DOAS) method, which has been applied to GOME and SCIAMACHY data. The main reasons for starting with two algorithms for total ozone have to do with heritage and past experience; our long-term goal is to combine the two to develop a more accurate and reliable total ozone product for OMI. We will compare the performance of these two algorithms by applying both of them to the GOME data. We will examine where and how the results differ, and use the extensive TOMS-Dobson comparison studies to assess the performance of the DOAS algorithm.

Veefkind, J. P.

Ozone Depletion at Mid-Latitudes: Coupling of Volcanic Aerosols and Temperature Variability to Anthropogenic Chlorine

Satellite observations of total ozone at 40-60 deg N are presented from a variety of instruments over the time period 1979-1997. These reveal record low values in 1992-3 (after Pinatubo) followed by partial but incomplete recovery. The largest post-Pinatubo reductions and longer-term trends occur in spring, providing a critical test for chemical theories of ozone depletion. The observations are shown to be consistent with current understanding of the chemistry of ozone depletion when changes in reactive chlorine and stratospheric aerosol abundances are considered along with estimates of wave-driven fluctuations in stratospheric temperatures derived from global temperature analyses. Temperature fluctuations are shown to make significant contributions to model calculated northern mid-latitude ozone depletion due to heterogeneous chlorine activation on liquid sulfate aerosols at temperatures near 200-210 K (depending upon water vapor pressure), particularly after major volcanic eruptions. Future mid-latitude ozone recovery will hence depend not only on chlorine recovery but also on temperature trends and/or variability, volcanic activity, and any trends in stratospheric sulfate aerosol.

Solomon, S.

GOME Calibration and Validation Using Backscatter UV Techniques

GOME radiance, irradiance, and ozone products were validated by NASA Goddard Space Flight Center through three tasks which included, pre-launch calibration comparisons with SBUV and TOMS radiometric standards, validation of GOME Level-1 irradiance and radiance and Level 2 total ozone data products using SBUV/2 and TOMS algorithms and data, and studies of GOME data using the Goddard radiative transfer code. The prelaunch calibration using the NASA large aperture integrating sphere was checked against that provided by TPD. Agreement in the calibration constants, derived in air, between the Goddard and TPD system were better than 3%. Validation of Level-1 irradiance data included comparison of GOME and SSBUV and the UARS solar irradiances measurements. Large wavelength dependent differences, as high as 10%, were noted between GOME and the US instruments. This discrepancy has now been attributed to radiometric sensitivity changes experienced by GOME when operating in a vacuum. GOME Earth radiance data were then compared to the NOAA-14 SBUV/2 radiances. These results show that between 340 and 400 nm the differences in GOME and SBUV/2 data are less than 5% with some wavelength dependence. At wavelengths shorter than 300 nm, differences are of the order of 10% or more where the GOME radiances are larger. To test GOME DOAS retrieved total ozone values, these values were compared with ozone amounts retrieved using GOME radiances in the TOMS version-7 algorithm. The differences showed a solar zenith angle dependence ranging from 0 to 10% where the TOMS algorithm values were higher. GOME radiances below 300 nm were further validated by selecting radiances at wavelengths normally used by SBUV and processing them through the SBUV ozone profile algorithm and then compared to climatological values. The GOME ozone profiles ranged from 10-30% lower over altitude compared to climatological values. This is consistent with the offsets detected in the SBUV/2 radiance comparisons at wavelengths shorter than 300 nm.

Hilsenrath, E.