Engineering Papers⌕ Search

Engineering topics

Glass, Christopher E.

Publications and source records attributed to Glass, Christopher E..

26 records · Page 2

The personal aircraft: Status and issues

Paper summarizes the status of personal air transportation with emphasis upon VTOL and converticar capability. The former obviates the need for airport operations for personal aircraft whereas the latter provides both ground and air capability in the same vehicle. Fully automatic operation, ATC and navigation is stressed along with consideration of acoustic, environmental and cost issues.

Anders, Scott G.↗

Calculating Flows With Interfering Shock Waves

Equilibrium Air Shock Interference, EASI, program takes account of dissociation of air molecules. Revives and updates older computational methods for calculating inviscid flow field and maximum heating from interference of shock waves. Expands methods to solve problems involving six shock-wave interference patterns on two-dimensional cylindrical leading edge with equilibrium, chemically-reacting gas mixture. Written in FORTRAN 77.

Glass, Christopher E.↗

Computer program to solve two-dimensional shock-wave interference problems with an equilibrium chemically reacting air model

The computer program EASI, an acronym for Equilibrium Air Shock Interference, was developed to calculate the inviscid flowfield, the maximum surface pressure, and the maximum heat flux produced by six shock wave interference patterns on a 2-D, cylindrical configuration. Thermodynamic properties of the inviscid flowfield are determined using either an 11-specie, 7-reaction equilibrium chemically reacting air model or a calorically perfect air model. The inviscid flowfield is solved using the integral form of the conservation equations. Surface heating calculations at the impingement point for the equilibrium chemically reacting air model use variable transport properties and specific heat. However, for the calorically perfect air model, heating rate calculations use a constant Prandtl number. Sample calculations of the six shock wave interference patterns, a listing of the computer program, and flowcharts of the programming logic are included.

Glass, Christopher E.↗

Three-dimensional thermal-structural analysis of a swept cowl leading edge subjected to skewed shock-shock interference heating

A three-dimensional flux-based thermal analysis method has been developed and its capability is demonstrated by predicting the transient nonlinear temperature response of a swept cowl leading edge subjected to intense three-dimensional aerodynamic heating. The predicted temperature response from the transient thermal analysis is used in a linear elastic structural analysis to determine thermal stresses. Predicted thermal stresses are compared with those obtained from a two-dimensional analysis which represents conditions along the chord where maximum heating occurs. Results indicate a need for a three-dimensional analysis to predict accurately the leading edge thermal stress response.

Polesky, Sandra P.↗

Experimental study of pressure and heating rate on a swept cylindrical leading edge resulting from swept shock wave interference

The effects of cylindrical leading edge sweep on surface pressure and heat transfer rate for swept shock wave interference were investigated. Experimental tests were conducted in the Calspan 48-inch Hypersonic Shock Tunnel at a nominal Mach number of 8, nominal unit Reynolds number of 1.5 x 10 to the 6th power per foot, leading edge and incident shock generator sweep angles of 0, 15, and 30 deg, and incident shock generator angle-of-attack fixed at 12.5 deg. Detailed surface pressure and heat transfer rate on the cylindircal leading edge of a swept shock wave interference model were measured at the region of the maximum surface pressure and heat transfer rate. Results show that pressure and heat transfer rate on the cylindrical leading edge of the shock wave interference model were reduced as the sweep was increased over the range of tested parameters. Peak surface pressure and heat transfer rate on the cylinder were about 10 and 30 times the undisturbed flow stagnation point value, respectively, for the 0 deg sweep test. A comparison of the 15 and 30 deg swept results with the 0 deg swept results showed that peak pressure was reduced about 13 percent and 44 percent, respectively, and peak heat transfer rate was reduced about 7 percent and 27 percent, respectively.

Glass, Christopher E.↗

Effect of leading edge sweep on shock-shock interference at Mach 8

These Mach 8 experimental results are applicable to the details of a shock-shock interference that may occur on an engine inlet of a hypersonic vehicle from a swept forebody shock interacting with a swept cowl leading edge bow shock or from a swept splitter plate shock interacting with a swept fuel injection strut bow shock. Peak surface pressure and heat transfer rate on the cylinder were about 10 and 30 times the undisturbed flow stagnation point value, respectively, for the 0 deg sweep test. A comparison of the 15 deg and 30 deg swept results with the 0 deg swept results shows that peak pressure was reduced about 13 percent and 44 percent, respectively, and peak heat transfer rate was reduced about 7 percent and 27 percent, respectively.

Glass, Christopher E.↗

Aerothermal tests of quilted dome models on a flat plate at a Mach number of 6.5

Aerothermal tests were conducted in the NASA Langley 8 Foot High Temperature Tunnel (8'HTT) at a Mach number of 6.5 on simulated arrays of thermally bowed metallic thermal protection system (TPS) tiles at an angle of attack of 5 deg. Detailed surface pressures and heating rates were obtained for arrays aligned with the flow and skewed 45 deg diagonally to the flow with nominal bowed heights of 0.1, 0.2, and 0.4 inch submerged in both laminar and turbulent boundary layers. Aerothermal tests were made at a nominal total temperature of 3300 R, a total pressure of 400 psia, a total enthalpy of 950 Btu/lbm, a dynamic pressure of 2.7 psi, and a unit Reynolds number of 400,000 per foot. The experimental results form a data base that can be used to help protect aerothermal load increases from bowed arrays of TPS tiles.

Glass, Christopher E.↗