Engineering PapersSearch

Engineering topics

Glasgow, V. L.

Publications and source records attributed to Glasgow, V. L..

Task 3 Milestone Report, Kennedy Space Center (KSC) LOX Loading Facility Analyses

Transient thermodynamic analyses have been made for the Kennedy Space Center (KSC) LOX loading system proposed for the space shuttle. The primary objective of these analyses is to predict the sensitivity of system performance to operating procedures, flow rate, temperature, and quality at the orbiter (ORB)/ground service equipment (GSE) interface. A further objective is to establish required system chill-down times. These analyses also include the prediction of transient thermodynamic conditions for the facility vent line, shuttle main engine (SSME) feed line entrance, ORB/ET interface, and the ET entrance (tank bottom).

Glasgow, V. L.

Shuttle LOX Loading Transient Study

The configuration and operation of the LOX loading facilities to be used for the space shuttle main propulsion test article at the National Space and Technology Laboratories (NSTL), and for the space shuttle launch facilities at John F. Kennedy Space Center (KSC) was investigated. The acceptability of these LOX loading facilities for each application was determined along with the degree of similarity between the systems with respect to the applicability of data developed during operations at NSTL a to the launch site operations at KSC. Results are summarized and final data comparisons, conclusions, and recommendations are presented.

Glasgow, V. L.

Shuttle LOX loading transient study. Task 2 milestone report. National space and technology laboratories (NSTL) LOX loading facility analysis

Transient thermodynamic analyses were made of the LOX loading system proposed for the space shuttle main propulsion test article (MPTA). This system is made up of a LOX replenish system and a main LOX line which include the barge tank, the lines, pumps, and valves between the barge and the orbiter (ORB) ground service equipment (GSE) interface, the MPTA fill system, the space shuttle main engine (SSME) chilldown bleed system, and the GSE vent system. System analyses include predictions of system performance sensitivity to operating sequence and LOX flowrate, temperature, and quality at the ORB/GSE interface. The transient thermodynamic conditions at the SSME feed line entrance, ET entrance (tank bottom), and the SSME bleed/GSE vent TEE are also included. The analyses are based on continuous SSME bleed flow during GSE facility chilldown.

Glasgow, V. L.

Fluid behavioral patterns found in subscale geysering study

Study provides a fundamental understanding of geysering mechanisms necessary for formulating theoretical analyses. An algebraic relationship between average heating rate, reservoir temperature, and geysering period was established and areas for future studies were identified.

Burkhalter, J. E.