Engineering PapersSearch

Engineering topics

Girard, A.

Publications and source records attributed to Girard, A..

Validation of nitrogen dioxide results measured by the limb infrared monitor of the stratosphere (LIMS) experiment on NIMBUS 7

The validation of results from the nitrogen dioxide channel and the quality of the data are examined in connection with the LIMS experiment which ran from late October 1978 to late May 1979. Factors studied include: channel characteristics, experiment errors due to instrument and spacecraft effects, predicted and measured precision, predicted accuracy, and comparisons with correlative measurements made in a series of balloon underflights. Features such as profile shape and slope of the mixing ratio altitude distribution are in good agreement. The LIMS data also fall within the range of previous mixing ratio measurements and are consistent with model estimates. The calculated on-orbit precision is about 0.3 ppbv and the estimated accuracy from simulations is about 2 ppbv over the 3-10-mbar range. Accuracy is less at higher and lower pressure levels. These results provide the first day-night set of nitrogen dioxide measurements from space.

Russell, J. M., III

Validation of water vapor results measured by the Limb Infrared Monitor of the Stratosphere experiment on Nimbus 7

In the LIMS experiment using thermal IR limb scanning to sound the composition and structure of the upper atmosphere, one of the LIMS channels was spectrally centered at 6.9 micrometers to measure the vertical profile and global distribution of stratospheric water vapor. This channel's characteristics, the data from it, and the steps taken to validate results are described. The mean difference between the LIMS measurements and data from 13 balloon underflights is about 0.6 ppmv with LIMS mixing ratios biased high; this difference is of about the same order as estimated LIMS accuracy and less than the sum of the errors for LIMS and the balloon techniques. In-orbit precision is 0.2-0.3 ppmv and accuracy is estimated at 20-30 percent from 50 mbar to the stratopause. An unexplained diurnal variation exists in the vertical profile data which is largest at the 1-mbar level and virtually nonexistent at 10 mbar; day values are higher than night. More confidence is placed in zonal mean distributions averaged over several days than in single profiles. A zonal mean pressure-latitude cross section is described for January 5-9, 1979.

Russell, J. M., III

Spectroscopy and transmittances for the LIMS experiment

The Limb Infrared Monitor of the Stratosphere (LIMS) instrument on the Nimbus 7 spacecraft sensed limb emission profiles for 7 months, starting in October 1979. Vertical temperature profiles are inferred from measurements in two CO2 channels, and constituent profiles are obtained form the O3, HNO3, NO2, and water vapor channels. The line parameters used to calculate transmittances in the retrieval algorithm are presented. Their adequacy for LIMS and for other applications are assessed, and recommendations for future investigations are outlined.

Drayson, S. R.

Grille spectrometer

High resolution infrared spectroscopic observations of the Earth's limb in the wavelength range characteristic of the vibrational-rotational lines of trace atmospheric constituents is planned. The instrument and its operation and the purpose of the experiments are summarized.

Ackerman, M.