Engineering Papers⌕ Search

Engineering topics

Gilman, R.

Publications and source records attributed to Gilman, R..

Measuring short-range correlations and quasi-elastic cross sections in A(e,e’) at x > 1 and modest Q 2

We present results from the Jefferson Lab E08-014 experiment, investigating short-range correlations (SRC) through measurements of inclusive quasi-elastic scattering from 2 H, 3 He, 4 He, 12 C, 40 Ca, and 48 Ca. The kinematics were selected to isolate scattering from SRCs, yielding a plateau in the A/ 2 H cross-section ratios due to the universal two-body structure of the 2N-SRCs in light and heavy nuclei. We observe approximate plateaus in the A/ 2 H ratios and provide the first extractions of the A/ 2 H ratio for 40 Ca and 48 Ca. We also examine the A/ 3 He ratio, aiming to identify three-nucleon SRCs (3N-SRCs). Following the approach for isolating 2N-SRCs, searching for 3N-SRC dominance involved measuring the A/ 3 He cross section ratio at modest-to-large Q 2 values and looking for a plateau ratios for x ≳ 2.5. This was not observed in the data, and in fact increasing Q 2 values moved the data further away from the predicted plateau. We show here that, when analyzed in terms of the struck nucleon’s light-cone momentum, the data exhibited the expected trend, progressively approaching the predicted 3N-SRC plateau. These observations suggest that future measurements at higher energies may facilitate a definitive isolation and identification of 3N-SRCs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Instrumental uncertainties in radiative corrections for the MUSE experiment

The MUSE experiment at the Paul Scherrer Institute is measuring elastic lepton-proton scattering cross sections in a four-momentum transfer range from Q 2 of approximately 0.002–0.08 GeV 2 using positively and negatively charged electrons and muons. The extraction of the Born cross sections from the experimental data requires radiative corrections. Estimates of the instrumental uncertainties in those corrections have been made using the ESEPP event generator. The results depend in particular on the minimum lepton momentum that contributes to the experimental cross section and the fraction of events with hard initial-state radiation that is detected in the MUSE calorimeter and is excluded from the data. Furthermore, these results show that the angular-dependent instrumental uncertainties in radiative corrections to the electron cross section are less than 0.4% and are negligible for the muon cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of longitudinal double-spin asymmetry measurements in semi-inclusive deep-inelastic scattering from the proton for the ECCE detector design

The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is presented, for the combinations of lepton and hadron beam energies of 5 × 41 GeV 2 and 18 × 275 GeV 2 . The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. Furthermore, the performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for e → τ charged lepton flavor violation at the EIC with the ECCE detector

The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ μ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e → τ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the τ-leptons created in the DIS process ep → τX are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong τ-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e → τ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in τ identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗