Engineering Papers⌕ Search

Engineering topics

Giacomini, G.

Publications and source records attributed to Giacomini, G..

At least 19 records

Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 µBq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.

47 OTHER INSTRUMENTATION↗

Overcoming photobleaching in imaging of single barium atoms in a solid xenon matrix

Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is 136 Xe, which would double beta decay into 136 Ba. Detecting the single 136 Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Pixel and Strip AC-LGAD Sensors with Different Design Parameter on a 120 GeV Proton Beam

We present the results of an extensive evaluation of strip and pixel AC-LGAD sensors tested with a 120 GeV proton beam, focusing on the influence of design parameters on the sensor temporal and spatial resolutions. Results show that reducing the thickness of pixel sensors significantly enhances their time resolution, with 20- μm-thick sensors achieving around 20 ps. Uniform performance is attainable with optimized sheet resistance, making these sensors ideal for future timing detectors. Conversely, 20-μm-thick strip sensors exhibit higher jitter than similar pixel sensors, negatively impacting time resolution, despite reduced Landau fluctuations with respect to the 50-μm-thick versions. Additionally, it is observed that a low resistivity in strip sensors limits signal size and time resolution, whereas higher resistivity improves performance. This study highlights the importance of tuning the n+ sheet resistance and suggests that further improvements should target specific applications like the Electron-Ion Collider or other future collider experiments. In addition, the detailed performance of four AC-LGADs sensor designs is reported as examples of possible candidates for specific detector applications. These advancements position AC-LGADs as promising candidates for future 4D tracking systems, pending the development of specialized readout electronics.

Lara, Carlos Pérez↗

Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

An integrated online radioassay data storage and analytics tool for nEXO

Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. Furthermore, this paper describes this database application, explains how it functions, and discusses how it streamlines the design of the experiment.

47 OTHER INSTRUMENTATION↗

First survey of centimeter-scale AC-LGAD strip sensors with a 120 GeV proton beam

We present the first beam test results with centimeter-scale AC-LGAD strip sensors, using the Fermilab Test Beam Facility and sensors manufactured by the Brookhaven National Laboratory. Sensors of this type are envisioned for applications that require large-area precision 4D tracking coverage with economical channel counts, including timing layers for the Electron Ion Collider (EIC), and space-based particle experiments. A survey of sensor designs is presented, with the aim of optimizing the electrode geometry for spatial resolution and timing performance. Several design considerations are discussed towards maintaining desirable signal characteristics with increasingly larger electrodes. The resolutions obtained with several prototypes are presented, reaching simultaneous 18 μm and 32 ps resolutions from strips of 1 cm length and 500 μm pitch. With only slight modifications, these sensors would be ideal candidates for a 4D timing layer at the EIC.

47 OTHER INSTRUMENTATION↗

Studies of event burst phenomenon with SiPMs in liquid nitrogen

Silicon photomultiplier (SiPM) are used to collect scintillation photons in many cryogenic noble liquid detectors deployed around the world, such as DarkSide, nEXO, MEGII, ProtoDUNE and DUNE. An event burst phenomenon was observed during routine characterization on many models of SiPMs operated in liquid nitrogen. These bursts of consecutive pulses are initiated by an intense dark photoelectron pulse with an event rate much lower than the time-uncorrelated thermal dark pulse. Although the rate of these burst events is very low, it can potentially compromise some dedicated rare physics event searches which are also anticipated to be of extremely low rate. Here, we systematically studied the behavior of the event burst phenomenon and identified the probable cause of the phenomenon. Here, this investigation is important for the selection of SiPMs for use in noble liquid detectors, high energy physics experiments, and industrial applications where SiPMs are used in cryogenic environment.

47 OTHER INSTRUMENTATION↗

Development of a large array of Silicon Drift Detectors for high-rate synchrotron fluorescence spectroscopy

An array of small-area Silicon Drift Detectors (SDD), named Hera, has been developed at Brookhaven National Laboratory (BNL) in the past few years. Its primary application is high-rate spectroscopy at synchrotrons. Each SDD pixel is a 1 mm × 1 mm square to match the footprint of the original diode-based pixel detector called Maia, which was developed for the same application. The replacement of the diode with an SDD allows for better energy resolution at short shaping times and an increased stability of the detector. 32, 96, and 384-channel arrays were designed and fabricated and achieved a Full Width Half Maximum (FWHM) as low as 176 eV at 5.9 keV with peaking time of 1 μs at -13°C. The sensor design, simulation, fabrication, its readout system, and its spectroscopic performance are reported.

47 OTHER INSTRUMENTATION↗

Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0νββ), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0νββ of 136 Xe with projected half-life sensitivity of 1.35 x 10 28 yr. To reach this sensitivity, the design goal for nEXO is ≤1% energy resolution at the decay Q-value (2458.07 ± 0.31 keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163 K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay Q-value for the nEXO design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a 127 Xe calibration source for nEXO

Here, we study a possible calibration technique for the nEXO experiment using a 127 Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay (0νββ) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in 136 Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of 127 Xe and its small Q-value compared to that of 136 Xe 0νββ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.

47 OTHER INSTRUMENTATION↗

Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam

We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. Here we studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6–10 μm position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.

47 OTHER INSTRUMENTATION↗

Electronics for Fast Timing

Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗