Qualification and Commissioning of Helium Flow Loop Experiment for Blanket Design Measurements

Sufficient cooling of plasma-facing materials remains an outstanding challenge in the design of fusion reactor blankets in commercial power demonstration plants. Due to its chemical inertness and low neutron interaction cross section, pressurized helium is a candidate coolant fluid for such systems; however, helium has a small thermal mass compared to liquid coolants, potentially reducing heat removal performance. To address this need, a number of heat transfer enhancements have been proposed to improve the cooling efficiency of such components, thereby decreasing pumping power needs and improving overall plant efficiency. Toward this end, a helium flow loop experiment (HFLE) has been designed and commissioned to test advanced passive heat transfer enhancements in unit-cell test sections, providing necessary data for model validation and subsequent system design. The HFLE is designed to provide flow of pressurized (up to 4 MPa) helium at flow rates up to 80 g/s, enabling heat transfer and pressure drop measurements in test pieces at Reynolds numbers in excess of 180 000. To explore the effects of novel and complex heat transfer enhancements, test sections are produced via additive manufacturing, providing geometries not typically obtainable by conventional machining. Here in this work, we present results from HFLE commissioning and the initial thermal-hydraulic tests of an additively manufactured rifled-rib test section. Results are compared to smooth pipe correlations, and plans are described for future HFLE measurements. These preliminary experiments indicate the utility of the HFLE for heat transfer enhancement testing and simulation validation activities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimized Test Section for Helium Flow Loop Experiment

Phase 3 of this project uses the knowledge and techniques gained from Phase 1 and Phase 2. The first outcome of Phase 3 is a new test section which can be manufactured and tested in the Helium Flow Loop Experiment to verify the results of the optimization study. The second outcome of Phase 3 is analyzing the features of this design and determining its performance under simulated TBM conditions: heat flux, pressure, mass flow rate, one-sided and volumetric heating. This will be accomplished by first using the results from the Phase 1 analyses and then applying the optimization strategy from Phase This phase uses the STAR-CCM+ Design Manager tool to apply the optimization strategy to the Helium Flow Loop Experiment (HFLE). The optimization algorithm used by the Design Manager tool is Simultaneous Hybrid Exploration that is Robust, Progressive, and Adaptive (SHERPA search algorithm). In addition to demonstrating the optimization features, a simple parameter sweep is also included in this phase. This report details the applied single objective optimization.

42 ENGINEERING↗

CFD Simulation of Helium Flow Loop Test Section

A helium flow loop is being assembled at Oak Ridge National Laboratory to analyze heat transfer enhancement for systems such as blanket and divertor components. To efficiently identify optimum geometries for heat transfer enhancement in these applications, simulation work is performed to optimize test section designs that are built and tested in the helium flow loop that operates at 4 MPa and a mass flow rate of 100 g/s. Different ribbed geometries that examine rib shape, rib height, rib orientation, rib spacing, and three dimensional orientation are modeled and simulated in STAR-CCM+ to compare their ability to remove heat and mitigate pressure drop. Following the simulations, models are selected and manufactured for the helium flow loop tests. Simulations initially focus on a hydrodynamic study to determine the appropriate mesh and physics models and then add a heat flux to analyze the heat transfer abilities of the models. The simulations are run in steady state and use a Reynolds-averaged Navier-Stokes k-ε turbulence model. The helium is modeled as an ideal gas. The simulation explores models of geometries that enhance the heat transfer and decrease pressure drop with an overall goal of increasing fluid collision with the wall. Enhanced geometries are simulated to select appropriate designs for manufacturing, and preliminary experimental results are used to validate the simulations. Furthermore, the factors that are being analyzed in the comparison between the experimental and the simulated results include matching thermocouple temperatures, pressure drop, roughness, and fluid velocity.

42 ENGINEERING↗

Transient computational and experimental thermal analysis of graphite foam monoblock

A densified graphite foam is being explored for its applicability as plasma-facing material in fusion devices. Three different graphite foam monoblocks are constructed and tested in the Garching Large Divertor Sample Testing Facility. The monoblock samples consist of graphite foam press-fit to a single tube, graphite foam cubes brazed to a single, and graphite foam cubes press-fit to a single tube. The tube is composed of CuCrZr with a steel twisted tape. The monoblocks are exposed to the heat fluxes of 5, 6, and 8 MW/m 2 for 30 s to determine the maximum surface and body temperatures measured with thermocouple for each monoblock design. The press-fit monoblocks are exposed to 8 MW/m 2 for 15 s for 100 cycles to determine the effect of thermal cycling on the contact between the graphite foam and the tube. STAR-CCM+ is used to predict how much the contact between the foam and tubes varies as a result of thermal cycling. In addition, the 6 MW/m 2 loading is modeled in STAR-CCM+ to compare the transient cooldown curves of the computational results to the recorded temperatures at the surface and two different thermocouple locations. This comparison is used to validate the temperature-dependent thermal conductivity and specific heat capacity used in the models of the graphite foam. The computational modeling of the experiment has been used to hypothesize ways to use and improve upon the graphite foam as a suitable material for fusion applications.

Gehrig, Monica↗

Development and Performance of Tungsten-Coated Graphitic Foam for Plasma-Facing Components

High-density graphitic foam is an ideal low-Z plasma-facing material for deuterium-deuterium plasma experiments where tritium codeposition is not an issue. However, like all carbon, graphitic foam suffers from a precipitous drop in thermal conductivity at high temperatures, >600°C. To mitigate these problems, functionally graded layers of tungsten can be deposited to a thickness of 2 to 4 mm onto the plasma side of the foam using chemical vapor deposition. The graphitic foam then acts as a high-conductivity heat sink at temperatures below 600°C for the thin high-Z armor coating. The overall component weighs 18 times less than a comparable volume of tungsten and lacks the coefficient of thermal expansion joining issues between the CuCrZr tubing and the tungsten. This paper discusses the coating development and characterization and presents the results of recent plasma exposures in W7-X. It also reports on computational fluid dynamics heat transfer modeling and preparations for high heat flux testing of mock-ups. This hybrid plasma-facing component (PFC) consisting of innovative engineered materials may be a cost-effective, actively cooled solution for the divertors and other PFCs in long-pulse machines like W7-X and WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High heat-flux response of high-conductivity graphitic foam monoblocks

Plasma-facing components based on the so-called monoblock design are planned for use in the divertor region of long-pulse plasma devices such as ITER and JT-60SA due to their capacity to handle high heat fluxes with active water cooling. The plasma-facing materials that are preferred for these monoblocks are tungsten for ITER or carbon-carbon fiber reinforced carbon (CFC) for JT-60SA. The requirements for the plasma-facing components include the ability to handle high plasma fluxes resulting in high temperatures. Therefore, reasonably high thermal conductivity is required. In this study, high thermal conductivity graphite foam is explored as a monoblock material. Four different test articles are created, two with the foam brazed to CuCrZr tubes, and two with the foam press fit to the tubes. These monoblocks are then thermally cycled at 8 MW/m 2 in the high heat-flux test facility GLADIS to examine their robustness for long-pulse divertor applications. Experimental results are compared with computational fluid dynamics simulation. Graphite foam shows promise for use in a plasma-facing component, but further development is necessary to address the significant drop in thermal conductivity at high temperatures.

Youchison, Dennis↗