Engineering Papers⌕ Search

Engineering topics

Gehl, Anthony C.

Publications and source records attributed to Gehl, Anthony C..

At least 37 records · Page 2

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean and High-Efficiency Natural Gas Furnace with Advanced Acidic Gas Trap Technology

Ccurrent natural gas condensing furnaces generate substantial acidic condensate and SOx/NOx/CO/HC/methane emissions, causing long-term environment issues related to air, water and soil. Acidic condensate occurs when flue gases within the furnaces cool down below the dew points of acidic gases, which upon condensation, combine with water vapor to produce acidic solutions. The acidic condensate causes serious corrosion and fouling problems in natural gas condensing furnaces. This paper presents a novel solution to use an advanced adsorption technology based on monolithic acidic gas trap (AGT) adsorbers for SOx trapping, NOx redox, and formic acid/CO/HC/methane oxidation, enabling a new natural gas furnace with utra-clean flue gas and neutral condensate. When the AGT adsorber is appropriately integrated with natural gas furnaces, the acidic gases of SOx, NOx and formic gas/CO/HC will be continuously adsorbed, redoxed or oxidized, respectively, from the flue gas during a regular heating season, except for occasional regeneration activities for SOx trapping. In the paper, we present results from a prototype furnace employing the novel AGT component, which enables a pH of the condensate =7, NOx emissions of 1-2 nanograms/joule and an annual fuel utilization efficiency (AFUE) of 96%, providing a cost-effective technology for condensing furnaces that is eco-friendly to the environment.

Gao, Zhiming↗

Heat Transfer and Pressure Drop Characteristics of Water Flow Boiling in Internally Enhanced Tubes

Flow boiling is a critical process for many thermal conversion processes such as HVAC&R, water heating, power generation and desalination applications. The major goal of this paper is to enhance the in-tube heat transfer for flow boiling of water and further improve the efficiency of the boiler. This paper presents an experimental investigation of the heat transfer and pressure drop characteristics for water under forced convection and boiling conditions inside both smooth and enhanced tubes. The results in the smooth copper tube are compared with several correlations and used as a baseline. The two-phase heat transfer and pressure drop performance of the water flow boiling in the internally enhanced tube is investigated, and the influence of internal surface pattern on the thermal characteristics is discussed. The relations of the heat transfer coefficient with mass flux, heat flux and vapor quality are analyzed according to the results.

Yang, Cheng-Min↗

A Numerical Analysis of The Pool Boiling Process in Flooded Evaporators Using Different Refrigerants

The pool boiling process can be observed in several energy conversion processes including commercial and industrial refrigeration, industrial air-cooling operations, and power generation. The process becomes more involved when pool boiling in a tube bundle is considered. In the current study, a numerical model is developed to predict the key performance parameters of a flooded evaporator while considering a range of working fluids. A kettle reboiler configuration was considered, and a performance model was developed to account for boiling on individual tubes, merging of vapor bubbles, and movement under gravity. A volume of fluid (VOF) model was used to deal with the different phases in the simulation. Various fluids were considered in this study including HFE-7000, HFE-7300, and water. The trajectories of the bubbles were tracked, and the resulting information has been summarized in physical measurable quantities.

Zhang, Mingkan↗

Evaluation of Interior Cellular Shades in a Residential Building

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope and sometimes from unwanted solar heat gain. Window attachments can help to mitigate this demand by controlling the solar heat gains and enhancing the thermal resistance of the windows. In this study, the energy savings potential of cellular shades in residential homes is studied using experimental testing and energy simulations. The energy performance of the shading devices was experimentally tested during the heating season from December 2019 to May 2020 with a focus on cellular shades. Five shading devices—three single and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal (venetian) blinds using two nearly identical sideby-side rooms in a residential building with their exterior window facing east. Another objective of the experimental testing was to evaluate any impact of the side-channel of the shading device on energy savings. To observe the impact of the side-channels on energy savings, from shades in two of the test cases, cellular shades with side-channels were used. From the experimental testing, daily energy savings in the range of 9% to 23% were observed by considering data from 6 p.m. until 6 a.m. of the next day.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical characterization of vertical-tube inlets in hot-water storage tanks

Hot-water storage in residential and commercial tanks is of growing interest for peak-shifting the electrical demand associated with hot-water loads. How the water enters the tank can significantly affect the extraction efficiency of the storage. Vertical-tube inlets (VTIs) direct cold water into the tank. The VTI design influences whether large-scale mixing occurs, which can reduce the delivery capacity of the hot-water storage. In this work, the mixing at the VTI discharge was characterized by the eddy diffusivity factor (EDF) in an allometric curve fit to the ratio Re:Ri using inlet superficial velocities. The full experimental campaign tested VTI's with Re’s between 170 and 22,300 and Ri's between 0 and 376. Animated visualization of the experimentally measured data is provided, showing tank temperature evolution during inlet flows. The most predictive correlations for EDF are for VTI Re in the transition zone (i.e. ~2300 < Re < ~10,000) and at a Ri corresponding to a stably stratified tank (i.e. Ri > 5). For vertical-tubes that distribute cold water below the thermocline, increasing the EDF will decrease the stratification in a hot-water tank as EDF quantifies inlet mixing. Overall, the new correlations for VTIs can be used to design and model thermally-stratified storage tanks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of Micro-Combined Heat and Power for Light Commercial Applications (Final Report)

In 2014 the United States Department of Energy (DOE) Building Technologies Office (BTO) funded a technology assessment of micro Combined Heat and Power (µCHP) systems for light commercial applications. The technology assessment was part of the BTO High Impact Technology (HIT) Catalyst program. The HIT Catalyst program supports research and development into technologies that will yield cost-effective, efficient buildings. It is estimated µCHP in US has the potential to save 10.5 GW of primary energy in the commercial building sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Installation Demonstration and Performance Evaluation of Composite Foam-Vacuum Insulation Boards in an Occupied Building

This article summarizes the installation demonstration of R25 composite insulation boards containing polyisocyanurate (PIR) foam-encapsulated modified atmosphere insulation (MAI) panels. The R25 boards can achieve a thermal resistance of 25 hr-ft2-°F/Btu within 2 inches of thickness (or R12/inch). MAI represents a lower-cost version of vacuum insulation panels (VIPs). The R25 composite boards were developed by the project team consisting of a foam insulation manufacturer, a vacuum insulation manufacturer and a research organization. R25 boards were used to retrofit a section of a low-slope roof. For comparison, adjacent roof sections were retrofitted with two layers of 2 inch regular PIR foam boardsThe retrofit installation was performed by professional roofing contractors and some weight-related issues were identified. In a follow-on discussion within the project team, mitigation methods were proposed. The long-term thermal performance of the R25 and regular PIR foam boards are being monitored using temperature and heat flow sensors installed above and below the insulation layers. Preliminary data analysis results are presented here.

Biswas, Kaushik↗

Furnace and Water Heater Venting Field Demonstration

A field demonstration was performed to evaluate the venting performance of the M&G DuraVent FasNSeal 80/90 venting system. The venting system uses a unique pipe within a pipe design to vent a condensing furnace and an natural-draft water heater, and can enable a condensing furnace to be installed in a home in which a condensing furnace could not otherwise be installed due to venting constraints. The field demonstration found that the FasNSeal 80/90 venting system successfully vented the orphaned water heater in each of the 16 demonstration homes and that the venting performance of the FasNSeal 80/90 venting system is generally comparable to the performance of venting systems initially installed in the 16 homes.

42 ENGINEERING↗

Big Data Mining for Assessing Calibration of Building Energy Models

Residential and commercial buildings in China, India, the United States (US), United Kingdom (UK), and Italy consume 39-45% of each nation's primary energy. Building energy models can be used to automatically optimize the return-on-investment for retrofits to improve a building’s energy efficiency. However, with an average of 3,000 building descriptors necessary to accurately simulate a single building, there is a market need to reduce the transaction cost for creating a more robust model for simulating every building in a city and accurately estimate savings prior to capital expenditures.We used two of the world’s fastest supercomputers, assembled unique datasets, and developed innovative algorithms for big data mining to assess different methods to create an accurate building energy model. The team has leveraged a total of eight high performance computing resources and 218 servers to analyze the best methods, metrics, and algorithms for creating an accurate building energy model beyond current industry standards necessary for private-sector financing. The project developed the world’s fastest buildings simulator, has completed over 8 million simulations totaling over 300TB, and mined this data with over 130,000 parallel artificial intelligence algorithms. This was used to quantify accuracy of AI-developed calibration algorithms with results that surpass industry standard guidelines and can identify individual building parameters to between 15% and 32% of their actual value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Long-Term Effects of Power Quality and Power Cycling on Thermoelectric Module Performance

Thermoelectric (TE) modules used in a heat pumping mode are increasingly being used for various applications involving heating and cooling. As their use becomes more prevalent and extends to lower cost applications using inexpensive commodity power supplies, it is important to characterize the long-term effects of power cycling and power quality on their performance. Two power supplies were evaluated with different levels of periodic and random deviations (PARD) from ideal DC power. This paper presents the results of an accelerated aging experimental study on intermittent power cycling of TE modules over the span of 5 actual months with each power supply. TE performance metrics that were monitored at specific time intervals are the AC resistance and figure of merit. The applied voltage, power consumption, TE hot and cold side temperatures and air temperatures were continuously measured. The experimental results indicate that the low-quality power supply quality had only a minor influence on properties and integrity of the TE modules, and is suitable for applications requiring intermittent use without a substantial reduction in performance.

Patel, Viral↗

Advanced control for ground source heat pump systems

Ground source heat pumps (GSHP), also known as geothermal heat pumps (GHP), are proven advanced HVAC systems that utilize clean and renewable geothermal energy, as well as the massive thermal storage capacity of the ground, to provide space conditioning and water heating for both residential and commercial buildings. GSHPs have higher energy efficiencies than conventional HVAC systems. It is estimated, if GSHPs achieve a 10% market share in the US, in each year, 0.6 Quad Btu primary energy consumption can be saved and 36 million tons carbon emissions can be avoided (Liu et al. 2017). However, the current market share of GSHPs is less than 1%. The foremost barrier preventing wider adoption of GSHPs is their high installation costs. To enable wider adoption of GSHPs, the costeffectiveness of GSHP applications must be improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Sensor for Measuring Pump Efficiency: Small Business Voucher Project with KCF Technologies

This document is to fulfill the final report requirements for the Small Business Voucher (SBV) CRADA project with ORNL and KCF Technologies (CRADA/NFE-16-06133). Pumping systems account for nearly 20% of the world’s electrical energy demand and range from 25-50% of the energy usage in many industrial and building power plants. The energy cost is the largest element in the total cost of owning a pump (~40%). In response to a recent DOE mandate for improved pump efficiency pump manufacturers are preparing for the changes that the impending regulations will bring, including design improvements. This mandate also establishes a need for new low cost pump efficiency measurement systems. The standard industry definition of pump efficiency is the mechanical water horsepower delivered divided by the electrical horsepower input to the motor. KCF Technologies has developed a new sensor measurement technique to estimate fluid pump efficiency using a thermodynamic approach. KCF Technologies applied for a SBV grant with ORNL as the research partner. KCF needed a research partner with the proper facilities to demonstrate the efficacy of its wireless sensor unit for measuring pump efficiency. The ORNL Building Technologies Research and Integration Center (BTRIC) test resources were used to test and demonstrate the successful measurement of pump efficiency with the KCF sensor technology. KCF is now working on next steps to commercialize this sensing technology.

42 ENGINEERING↗

Field Demonstration of Ground-Source Integrated Heat Pump - Final Report

Reducing energy consumption in buildings is key to reducing or limiting the negative environmental impacts from the building sector. According to the United States (U.S.) Energy Information Administration (EIA), in 2013, commercial buildings consumed 18.1 quads of primary energy, which was 18.6% of the total U.S. primary energy consumption. The primary energy consumption in the commercial sector is projected to increase by 2.8 quads from 2013 to 2040, the second largest increase after the industrial sector. Further space heating, space cooling, and ventilation (HVAC) services accounted for 31% of the energy consumption in commercial buildings. The technical objective of this project is to demonstrate the capability of the new GS-IHP system to reduce overall energy use for space heating, space cooling, and water heating by at least 45% vs. a conventional electric RTU and electric WH in a light commercial building application. This project supports the DOE-Building Technologies Office (BTO) goals of reducing HVAC energy use by 20% and water heating by 60% by 2030.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Demonstration of Ground-Source Integrated Heat Pump Part I. Technology and Field Demo System/Site Descriptions, and Preliminary Summer/Fall Performance Analysis for One Site

The field study is planned to continue through the 2016 cooling season with the draft final project report due by September 30, 2016. This report provides a description of both installations and preliminary 2015 cooling and fall season performance results for the Knoxville site. For the August 18 through December 14 period, the Knoxville site GS-IHP provided 53.6% total source energy savings compared to a baseline electric RTU/heat pump and electric WH. Peak demand savings ranged from 33% to 59% per month. Energy cost savings of 53.1% have been achieved to date with more than half of that coming from reduced demand charges. Data on installation and maintenance costs are being collected and will be combined with total test period energy savings data for a payback analysis to be included in the project final report. The GS-IHP also saved a significant amount of carbon emissions. The total emission savings for the Knoxville site for the August-December 2015 period were ~0.8 metric tons. If trading for carbon credits ever becomes a reality, additional cost savings would be realized.

20 FOSSIL-FUELED POWER PLANTS↗