Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental Study of Acceptor Removal in UFSD

The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. In this study, the effect is tested both with capacitance–voltage, C–V, measurements of the doping concentration and with measurements of charge collection, CC, using charged particles. We find a perfect linear correlation between the bias voltage to deplete the gain layer determined with C–V and the bias voltage to collect a defined charge, measured with charge collection. An example for the usefulness of this correlation is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Layout and performance of HPK prototype LGAD sensors for the High-Granularity Timing Detector

The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology, will cover the pseudo-rapidity region of 2.4 < |n| < 4.0 with two end caps on each side and a total area of 6.4 m 2 . The timing performance can be improved by implanting an internal gain layer that can produce signals with a fast rising edge. It significantly improves the signal-to-noise ratio. The required average timing resolution per track for a minimum ionizing particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1MeV neutron-equivalent fluence up to 2.5 10 15 n eq /cm 2 including a safety factor of 1.5 before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-ups at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.

47 OTHER INSTRUMENTATION↗

Radiation campaign of HPK prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

In this work, we report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of were irradiated in steps of roughly 2 up to a fluence of 3. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at °C.

47 OTHER INSTRUMENTATION↗

Properties of HPK UFSD after neutron irradiation up to 6e15 n/cm 2

In this article we report results from a neutron irradiation campaign of Ultra-Fast Silicon Detectors (UFSD) with fluences of 1e14, 3e14, 6e14, 1e15, 3e15 and 6e15 neq/cm 2 . The UFSD used in this study are circular 50 μm thick Low-Gain Avalanche Detectors (LGAD), with a 1.0 mm diameter active area. Hamamatsu Photonics (HPK), Japan, produced the UFSD with pre-irradiation internal gain in the range 5–70 depending on the bias voltage. The sensors were tested pre-irradiation and post-irradiation with minimum ionizing particles (MIPs) from a 90 Sr β-source. The leakage current, internal gain and the timing resolution were measured as a function of bias voltage at -20 °C and -30 °C. The timing resolution of each device under test was extracted from the time difference with a second calibrated UFSD in coincidence, using the constant fraction discriminator (CFD) method for both. The dependence of the gain upon the irradiation fluence is consistent with the acceptor removal mechanism; at -20 °C the highest gain decreases from 70 before radiation to 2 after a fluence of 6e15 n/cm 2 . Consequently, the timing resolution was found to deteriorate from 20 ps to 50 ps. The results indicate that the most accurate time resolution is obtained varying with fluence the CFD value used to determine the time of arrival, from 0.1 for pre-irradiated sensors to 0.6 at the highest fluence. Key changes to the pulse shape induced by irradiation, i.e. (i) the contribution of charge multiplication not limited to the gain layer zone, (ii) the shortening of the rise time and (iii) the reduced pulse height, were compared with the WF2 simulation program and were found to be in agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Technologies for Discovery

For the field of high energy physics to continue to have a bright future, priority within the field must be given to investments in the development of both evolutionary and transformational detector development that is coordinated across the national laboratories and with the university community, international partners and other disciplines. While the fundamental science questions addressed by high energy physics have never been more compelling, there is acute awareness of the challenging budgetary and technical constraints when scaling current technologies. Furthermore, many technologies are reaching their sensitivity limit and new approaches need to be developed to overcome the currently irreducible technological challenges. This situation is unfolding against a backdrop of declining funding for instrumentation, both at the national laboratories and in particular at the universities. This trend has to be reversed for the country to continue to play a leadership role in particle physics, especially in this most promising era of imminent new discoveries that could finally break the hugely successful, but limited, Standard Model of fundamental particle interactions. In this challenging environment it is essential that the community invest anew in instrumentation and optimize the use of the available resources to develop new innovative, cost-effective instrumentation, as this is our best hope to successfully accomplish the mission of high energy physics. This report summarizes the current status of instrumentation for high energy physics, the challenges and needs of future experiments and indicates high priority research areas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗