Engineering Papers⌕ Search

Engineering topics

Gavron, Victor

Publications and source records attributed to Gavron, Victor.

Current Status of Helium-3 Alternative Technologies for Nuclear Safeguards

International safeguards inspectorates (e.g., International Atomic Energy Agency {IAEA}, or Euratom) rely heavily on neutron assay techniques, and in particular, on coincidence counters for the verification of declared nuclear materials under safeguards and for monitoring purposes. While 3 He was readily available, the reliability, safety, ease of use, gamma-ray insensitivity, and high intrinsic thermal neutron detection efficiency of 3 He-based detectors obviated the need for alternative detector technologies. However, the recent decline of the 3 He gas supply has triggered international efforts to develop and field neutron detectors that make use of alternative materials. In response to this global effort, the U.S. Department of Energy’s (DOE) National Nuclear Security Administration (NNSA) and Euratom launched a joint effort aimed at bringing together international experts, technology users and developers in the field of nuclear safeguards to discuss and evaluate the proposed 3 He alternative materials and technologies. The effort involved a series of two workshops focused on detailed overviews and viability assessments of various 3 He alternative technologies for use in nuclear safeguards applications. The key objective was to provide a platform for collaborative discussions and technical presentations organized in a compact, workshop-like format to stimulate interactions among the participants. The meetings culminated in a benchmark exercise providing a unique opportunity for the first inter-comparison of several available alternative technologies. This report provides an overview of the alternative technology efforts presented during the two workshops along with a summary of the benchmarking activities and results. The workshop recommendations and key consensus observations are discussed in the report, and used to outline a proposed path forward and future needs foreseeable in the area of 3 He-alternative technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for a measurement of the 237 U(n,f) cross section at the LANSCE Lujan Center

A new measurement of the 237 U(n, f) cross section from thermal to ≈ 100 keV is discussed, using one of the flightpaths at the LANSCE Lujan Center. Previous energy-resolved resonance-region measurements have been conducted using weapon test time-of-flight and the LANSCE Lead Slowing Down Spectrometer, the former of which is limited in its energy range, and the latter in its energy resolution and range. We present here a proposal, based on simulations of the Lujan Center neutron flux and a hypothetical experiment, that is expected to adequately address both of these issues.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Lead Slowing Down Spectrometer Research Plans

The MPACT-funded Lead Slowing Down Spectrometry (LSDS) project has been evaluating the feasibility of using LSDS techniques to assay fissile isotopes in used nuclear fuel assemblies. The approach has the potential to provide considerable improvement in the assay of fissile isotopic masses in fuel assemblies compared to other non-destructive techniques in a direct and independent manner. The LSDS collaborations suggests that the next step to in empirically testing the feasibility is to conduct measurements on fresh fuel assemblies to understand investigate self-attenuation and fresh mixed-oxide (MOX) fuel rodlets so we may better understand extraction of masses for 235 U and 239 Pu. While progressing toward these goals, the collaboration also strongly suggests the continued development of enabling technology such as detector development and algorithm development, which could provide significant performance benefits.

Lead slowing down spectrometry↗

MPACT LSDS Progress Report: LANL and LANL-Funded Activities in Support of Spent Fuel Measurements Using a Lead Slowing Down Spectrometer in FY 2012

During FY 2012, Lead Slowing Down Spectrometer (LSDS) measurement campaigns took place at the Los Alamos Neutron Science Center, and the Rensselaer Polytechnic Institute. At Los Alamos, we measured the response of a thorium fission chamber to a 25 gram plutonium sample, and evaluated the performance of a 4 He-filled proportional counter. At RPI, the effort lead by Professor Danon, performed an assay of fuel pins, and used a fission chamber with plutonium to evaluate the impact of room return.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Does LSDS Analysis Require More Than One Isotopic Fission Chamber?

One of the methods of analysis of spectra measured in a Lead Slowing Down Spectrometer (LSDS) requires the measurement of time spectra in isotopic fission chambers (e.g., chambers lined with 235 U and 239 Pu), in addition to the measurement in threshold fission chambers. Since there is a correspondence between time after the initiating neutron pulse, and the neutron energy, it would seem possible that the response in one isotopic chamber can be converted to the response of any other isotopic fission chamber using the cross-section ratio of the fissile materials.

Nuclear Fuel Cycle & Fuel Materials(11)↗

Presentation to JAEA Visitors, July 24, 2012 [Slides]

There are 7 Reasons for characterizing spent fuel nuclide concentrations: (1) Provide IAEA with the capability to independently verify the mass of plutonium at any site that has spent fuel; (2) Shipper/receiver difference; (3) Determination of the input accountability mass of an electrochemical (pyro-chemical) processing facility; (4) Continuity of knowledge at spent fuel storage site; (5) Optimal reloads through knowledge of true actinide content; (6) Burnup credit for fuel transport and storage; and (7) Provide confidence to the public that the shipment of spent fuel around the world is being undertaken in a rigorous manner, assuring that material is not diverted during shipment. Types of fuel of interest are: Fast Reactor Fuel, Normal burnup low enriched uranium (LEU), Mixed oxide (MOX), Low burnup LEU, and Research reactor. MCNPX calculates the slowing down and the energy spread for a given time. The principles are: (1) Neutrons slow down in LSDS; (2) Slow neutrons capture preferentially on a fission resonance; (3) Fission emits high-energy neutrons; (4) High-energy neutrons detected in threshold detector (that is not sensitive to slow neutrons) (e.g., 238 U, 232 Th); and (5) The detection time is characteristic of the slow neutron energy. Following each PSR pulse, the entire signal is digitized in 2 nanosecond intervals, and subsequently analyzed Analysis involves applying a digital filter to extract fission pulses in a background of initial oscillations and noise throughout. Some of the noise is not random. Depending on the threshold setting and filter parameters, both the normalization and the trend change. Original PNNL LSDS design required a 1-meter radius cylindrical LSDS. Much higher efficiency would allow us to use a (1.2m) LSDS (this is the LANL LSDS size), or a less intense source, or a combination of both. We still estimate 10 16 total neutrons from the source to obtain 2-3% precision in 239 Pu and 235 U assay.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗