Engineering Papers⌕ Search

Engineering topics

Gastis, Panagiotis

Publications and source records attributed to Gastis, Panagiotis.

Microjet printing of metal salt or oxide targets for nuclear reaction studies on radionuclides

Radioactive targets for direct measurements of neutron-induced reactions are required to improve evaluated cross-section data and, ultimately, the fidelity of neutron reaction network simulations. Electrodeposition and molecular plating are the current state-of-the-art radioactive target production techniques, but not all metals can be electrodeposited or molecular plated with high yields. Alternative techniques can be expensive or may produce targets that are unsatisfactory in terms of thickness, yield, or purity. Microjet printing is a new, rather inexpensive technique that utilizes equipment with a small footprint and has the potential to produce thin, highly radioactive targets with good uniformity and minimal impurities from the target fabrication process. This study involved optimizing the process of producing microjet printed targets to allow for the fabrication of a stable vanadium(V) oxide (V 2 O 5 ) target that was compared with an analogous electrodeposition V 2 O 5 target manufactured via the application of a vanadium chemical conversion coating on aluminum (Al) foil. Finally, the results from these studies suggest microjet printing could be used to produce relatively uniform target layers with adequate film thicknesses (< 15 μm). V 2 O 5 microjet printed targets, when compared with chemical conversion coating V 2 O 5 targets, appeared to be qualitatively less uniform and quantitatively larger in thickness (11.7(27) μm vs. 5.3(18) μm). However, the conversion coating target contained more impurities and the Al backing had a higher background contribution to measurements of neutron-induced reactions as opposed to targets produced via microjet printing. Overall, the results from this study suggest microjet printing has the capability to be an excellent alternative target production technique to the electrodeposition and molecular plating methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrospraying deposition and characterization of potassium chloride targets for nuclear science measurements

Natural and isotopically enriched KCl targets were prepared using specially formulated KCl solutions, deposited by electrospraying on thin (1.5 μm) gold backings, followed by a short annealing in a preheated (350-450 °C) furnace. Various techniques, such as X-ray fluorescence (XRF), scanning electron microscopy (SEM) imaging, and energy-dispersive X-ray spectroscopy (EDS), were used to characterize the produced targets. A white neutron beam at the Los Alamos Neutron Science Center (LANSCE) facility was also used to verify the estimated atomic percentages of the enriched 40 KCl targets. KCl was deposited relatively uniformly as large particles rather than films on the gold surface. As a result, this method can be broadly extended to make stable targets that are difficult to produce with other methods and more exotic radioactive targets required for research in fundamental sciences and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cross-section measurement of the 82 Kr ($p,γ$) 83 Rb reaction in inverse kinematics

The total cross section of the 82 Kr(p,γ) 83 Rb reaction was measured for the first time at effective center-of-mass energies between 2.4 and 3.0 MeV, within the relevant Gamow window for the astrophysical γ process. The experiment took place at the National Superconducting Cyclotron Laboratory at Michigan State University using the ReA facility. A 82 Kr beam was directed onto a hydrogen gas cell located at the center of the Summing NaI(Tl) (SuN) detector. Here, the obtained spectra were analyzed using the γ-summing technique and the extracted cross section was compared to standard statistical model calculations using the non-smoker and talys codes. The comparison indicates that standard statistical model calculations tend to overproduce the cross section of the 82 Kr(p,γ) 83 Rb reaction relative to the experimentally measured values. Furthermore, the experimental data were used to provide additional constraints on the nuclear level density and the γ-ray strength function used in the statistical model calculations.

59 ≤ A ≤ 89↗

The LANSCE experimental program: accelerator requirements

The LANSCE accelerator complex exploits a flexible, high power 800 MeV proton linear accelerator to enable a broad swath of experimental work supporting multiple scientific programs. The beam requirements for these programs are diverse and change over time. The purpose of this document is to record, at a high level, the experimental requirements driving the beam delivery requirements for each experimental facility at LANSCE. Revision 0 serves to baseline the current set of experiments, and we expect to revise the document on an as-needed basis when either the experimental requirements change or are found to require a more complete definition.

43 PARTICLE ACCELERATORS↗

Absolute mass calibration of fission product distributions measured with the E-$v$ method

The mass calibration of fission product distributions measured with the energy–velocity (E-v) method constitutes a technical challenge. The energy loss of the fission fragments in the various dead layers of the spectrometer and other sources of pulse-height defects of the energy detectors are a significant source of systematic uncertainty in the mass calculations used to determine the measured fission product yields. Here, in this study, the absolute calibration of the fission mass distributions is accomplished by measuring prompt γ-rays in coincidence with the fission fragments. This allows for the direct calibration of the mass spectra and eliminates any dependence on potentially complicated energy corrections. The first test measurement was performed at the Los Alamos Neutron Science Center employing the SPectrometer for Ion DEtermination in fission Research (SPIDER). SPIDER is a 2E-2v spectrometer designed for measuring independent fission product yields from neutron-induced fission. In this test, the single-arm SPIDER (E-v) system and an array of 252 Cf sources were used. The single-arm system consisted of two time pick-off detectors for measuring the time-of-flight of the fission fragments and a double-sided silicon strip detector (DSSD) for measuring the kinetic energy. Characteristic γ-rays from fission fragments were detected using three high-purity germanium (HPGe) detectors. For the mass calibration, γ–mass coincidence events from twelve product isotopes were used. The measured FPYs from 252 Cf spontaneous fission were found to be in excellent agreement with the evaluated data after applying the absolute mass calibration. From the γ–mass coincidence events, the mass resolution of the system was also extracted. An average mass resolution of ~1.4 AMU (FWHM) for the light fragments and ~2.4 AMU (FWHM) for the heavy fragments were found. This was the first in-situ calibration and characterization of the SPIDER spectrometer, which paves the way for high-quality FPY measurements with this instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗