Evolving efforts to maintain and improve XPS analysis quality in an era of increasingly diverse uses and users

Based on literature analysis, X-ray photoelectron spectroscopy (XPS) use continues to increase exponentially. This increased use is accompanied by anecdotal reports and systematic analyses indicating a growing presence of significantly flawed data analyses. Recognition of this problem within the surface analysis community has increased with an understanding that both inexperienced users and increased use of XPS outside the surface analysis community contribute to the problem. The XPS community has initiated several efforts to help address the problem, which is not unique to XPS. This paper describes some of the specific problems identified and some of the community efforts intended to address them. Here, we describe activities focused on three specific issues: (i) requests for detailed guides and protocols and bite-sized versions of information for non-experts, (ii) incomplete data and analysis reporting, and (iii) the high rate of peak fitting problems. A 2019 survey identified the need for guides, protocols, and standards to assist XPS users. One set of such guides has been published, and another is being assembled. Providing incremental bites of useful information is the goal of a series of papers on specific challenges to surface analysis with example solutions has been initiated as Notes and Insights papers in Surface and Interface Analysis. Examination of XPS-containing papers finds that information to establish the credibility and reproducibility of XPS results is often very incomplete. Unfortunately, ISO and ASTM standards require an amount of parameter reporting that seems excessive and unrealistic for many research publications. Initial approaches to develop and distribute a graded approach to parameter reporting are briefly described. Multiple efforts are underway to address the high rate of problems associated with photoelectron peak fitting. These include guides to peak fitting, guides to peak identification and fitting for specific elements, and the development of a peak fitting social network. The fitting social network is designed to facilitate interactions between new and experienced XPS users; analysts trying to fit XPS data (for publication or other reasons) can ask questions and establish dynamic conversations. Encouraging and enabling high-quality XPS analysis and reporting requires several different types of effort from all members of the surface and interface analysis community.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗