Engineering Papers⌕ Search

Engineering topics

Garcia, F.

Publications and source records attributed to Garcia, F..

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel diamond-like carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timinggaseous detector based on a MM detector operating in a two-stageamplification mode and a Cherenkov radiator. Prototypes equippedwith cesium iodide (CsI) photocathodes have shown promising timeresolutions as precise as 24 picoseconds (ps) for Minimum IonizingParticles. However, due to the high hygroscopicity andsusceptibility to ion bombardment of the CsI photocathodes,alternative photocathode materials are needed to improve therobustness of PICOSEC MM. Diamond-like Carbon (DLC) film have beenintroduced as a novel robust photocathode material, which have shownpromising results. A batch of DLC photocathodes with differentthicknesses were produced and evaluated using ultraviolet light. Thequantum efficiency measurements indicate that the optimizedthickness of the DLC photocathode is approximately3 nm. Furthermore, DLC photocathodes show good resistance to ionbombardment in aging test compared to the CsI photocathode. Finally,a PICOSEC MM prototype equipped with DLC photocathodes was tested inmuon beams. A time resolution of around 42 ps with a detectionefficiency of 97% for 150 GeV/c muons were obtained. These resultsindicate the great potential of DLC as a photocathode for thePICOSEC MM detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote operation of the DIII-D National Fusion Facility

Abstract Full remote scientific operation of the DIII-D National Fusion Facility is now possible through significant advances in the computer science hardware and software infrastructure made over the last decade. Capabilities around information visualization, data movement, and communication have all been enhanced. The level of capability deployed to remotely operate DIII-D required an infrastructure advancement over what had previously been achieved in the fusion community. The large quantity of real-time data that is automatically displayed on DIII-D’s control room screens can now be visualized by remote participants via web-based applications. New audio/video solutions using the VoIP and instant messaging application Discord have been implemented to mimic the dynamic and ad-hoc scientific conversations that are critical in successfully operating an experimental campaign. Discord’s ability for a user to rapidly move between audio channels, text with images, and share screens is a significant enhancement over traditional videoconferencing tools. In addition, multiple combinations of broadcast audio are made available via a web-based application to allow remote participants to simultaneously listen to general announcements/sounds while conducting their own specific conversations. Secure methodologies have been put into place to allow remote control of hardware including DIII-D’s plasma control system application. Secure methods also included the ability of the on-site team to closely coordinate their work with remote team members which has been enhanced through extensions to the wireless network and the use of tablet computers for audio/video/screen sharing. However, no amount of software can fully replace the need for ‘hands on hardware.’ This infrastructure was severely stress tested during the COVID-19 pandemic where occupancy of the DIII-D control room was restricted. Operational efficiency during the pandemic, measured in discharges per hour, remained high (3.8 ± 0.8) compared to values obtained pre-pandemic (3.7 ± 0.8).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel PICOSEC MM prototype with 10 × 10 cm 2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below σ = 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects, i.e. integration of resistive MM and carbon-based photocathodes, while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below σ = 20 ps for an individual pad obtained with the 10 × 10 cm 2 area resistive PICOSEC MM of 20 MΩ/$\square$ showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B 4 C) photocathode presented a time resolution below σ = 35 ps, opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

RETHGEM↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF 4 . Initially, pure CF 4 will be used, and then in mixtures containing other elements employed by leading dark matter search technologies — including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process — an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF 4 we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D–D (D–T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5σ median discovery significance can be achieved in under one day with either generator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Habitability: CAMELOT 4

During 1988 to 1989 the NASA/USRA Advanced Design Program sponsored research and design efforts aimed at developing habitability criteria and at defining a habitability concept as a useful tool in understanding and evaluating dwellings for prolonged stays in extraterrestrial space. The Circulating Auto sufficient Mars-Earth Luxurious Orbital Transport (CAMELOT) was studied as a case in which the students would try to enhance the quality of life of the inhabitants by applying architectural design methodology. The study proposed 14 habitability criteria considered necessary to fulfill the defined habitability concept, which is that state of equilibrium that results from the interaction between components of the Individual Architecture Mission Complex, which allows a person to sustain physiological homeostatis, adequate performance, and acceptable social relationships. Architecture, design development, refinements and revisions to improve the quality of life, new insights on artificial gravity, form and constitution problems, and the final design concept are covered.

Alequin, W.↗

Test results for sawtooth-pattern damper seals - Leakage and rotordynamic coefficients

Test results consisting of direct and transverse force coefficients are presented for eleven sawtooth-pattern damper-seal configurations. The designation 'damper' seal refers to a seal which uses a deliberately roughened stator and smooth rotor to increase the net seal damping force. The designation 'sawtooth-pattern' refers to a stator-roughness pattern whose cross section normal to the axis of the seal resembles saw teeth with the teeth direction opposing fluid motion in the direction of shaft rotation. The sawtooth pattern yields axial grooves in the stator which are interrupted by spacer elements which act as flow constrictions or 'dams'. Sawtooth-pattern seals had more damping than smooth seals but less than the round-hole-pattern seals tested previously. If damping is sacrificed, sawtooth-pattern seals can be designed to leak less than round-hole-pattern seals.

Childs, D.↗