Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING↗

A Dynamic Model of Refrigerator with Thermal Energy Storage for Demand Flexibility

A refrigerator is an essential appliance for both commercial and residential applications. Thermal (Cold) energy storage can effectively reduce the carbon emission from refrigerators. This preliminary study investigated the demand flexibility of a domestic refrigerator using thermal (cold) energy storage through dynamic modeling and controls. The models include both fresh and frozen compartments, a vapor compression cycle loop, and thermal storage panels. Results show that thermal energy storage can effectively achieve temperature control of the compartments within the 4-hour time window. The load reduction and cost savings (46.3%) were achieved through the TES using TOU rates.

Gao, Zhiming↗

High Temperature Heat Pumps and Their Roles in the Decarbonization of Building and Industry

Heat pumps have been sought as a promising technology for air and water heating processes in buildings. Several OEMs have been commercializing heat pumps with varying capacities; However, the application has been limited to lower temperatures (less than 70℃). With the recently growing interest in replacing gas-fired equipment for buildings and industrial processes, a new class of heat pumps, known as high-temperature heat pumps, is gaining substantial interest where the target temperatures are higher than the conventional heat pump technology (greater than 90℃). The current study is focused on this class of heat pumps and aims to provide a holistic overview of state-of-the-art technology while highlighting major challenges and opportunities. The discussion will be focused on the availability of technology to enable higher sink temperatures, deployment-based applications, waste heat recovery, and process integration and controls.

Nawaz, Kashif↗

Benchmark Testing of Two Residential Refrigerators Using R-600a

Household refrigerators provide a convenient and safe means of food preservation and storage. More than 100 million refrigerators are used in US homes, resulting in significant primary energy consumption and carbon emissions. As a greenhouse gas with a 100-year global warming potential of 1,430, R-134a has been banned in new US domestic refrigerators and freezers since 2021, and R-600a with a global warming potential of 3 is widely employed as a working fluid in the current US household refrigerator market. In this paper, benchmark testing was conducted for two 2023 refrigerators using R-600a. Moreover, the effect of representative customer use patterns, such as door opening and warm food storage, was studied to evaluate the effect on the energy consumption of the refrigerators. These results will provide background knowledge for facilitating the integration of new technologies to achieve significantly reduced greenhouse gas emissions in future efficient refrigerators.

Gao, Zhiming↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

Development of a micro-combined heat and power powered by an opposed-piston engine in building applications

Residential homes and light commercial buildings usually require substantial heat and electricity simultaneously. A combined heat and power system enables more efficient and environmentally friendly energy usage than that achieved when heat and electricity are produced in separate processes. However, due to financial and space constraints, residential and light commercial buildings often limit the use of traditional large-scale industrial equipment. Here we develop a micro–combined heat and power system powered by an opposed-piston engine to simultaneously generate electricity and provide heat to residential homes or light commercial buildings. The developed prototype attains the maximum AC electrical efficiency of 35.2%. The electrical efficiency breaks the typical upper boundary of 30% for micro–combined heat and power systems using small internal combustion engines (i.e., <10 kW). Moreover, the developed prototype enables maximum combined electrical and thermal efficiencies greater than 93%. The prototype is optimally designed for natural gas but can also run renewable biogas and hydrogen, supporting the transition from current conventional fossil fuels to zero carbon emissions in the future. The analysis of the unit’s decarbonization and cost-saving potential indicate that, except for specific locations, the developed prototype might excel in achieving decarbonization and cost savings primarily in US northern and middle climate zones.

24 POWER TRANSMISSION AND DISTRIBUTION↗

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Class 8 Long-Haul Truck Electrification: Key Technology Evaluation and Potential Challenges

The phenomena of global warming and climate change are encouraging more and more countries, local communities, and companies to establish carbon neutrality targets, which has very significant implications for the US trucking industry. Truck electrification helps fleets to achieve zero tailpipe emissions and macro-scale decarbonization while allowing continued business growth in response to the rapid expansion of e-commerce and shipping related to increased globalization. Here, this paper presents an analysis of Class 8 long-haul truck electrification using a commercial vehicle electrification evaluation tool and Fleet DNA drive data. The study provides new insight into the impacts of streamlined chassis, battery energy density, and superfast charging on battery capacity needs as well as implications for payload, energy consumption, and greenhouse gas emissions for electric long-haul trucks. The study also identifies a pathway for achieving optimal long-haul truck electrification. The results show that no single technology can simultaneously achieve significant improvements in all these key areas and that a cost-effective approach requires a deliberate combination of all of these technologies. Moreover, the analysis highlights the strong evolution of vehicle and battery technologies and the excellent potential for long-haul truck electrification to achieve 100% year-round service coverage with continued technology advancement.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Clean Condensing Furnace Using Advanced Catalyst

A clean condensing furnace was developed by using acidic gas reduction (AGR) catalysts. The AGR catalyst technology is capable of minimizing condensate acidity and NOx emissions in advanced gas furnace. In the study, different AGR catalyst materials were explored. The AGR with low Pt/Rh loading achieves an improved annual fuel utilization efficiency (AFUE) without impairing the performance in achieving neutral condensate and ultralow NOx emissions. The AGR with low Pt/Rh loading enables even better ability to convert NOx. Moreover, the low-cost AGR realizes nearly zero cold-start CO emissions, as is attractive in the battle to keep public safe from dangerous CO in furnaces.

Gao, Zhiming↗

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗

Sequential Dual Alignments Introduce Synergistic Effect on Hexagonal Boron Nitride Platelets for Superior Thermal Performance

Planarly aligning 2D platelets is challenging due to their additional orientational freedom compared to 1D materials. Here, this study reports a sequential dual-alignment approach, employing an extrusion-printing-induced shear force and rotating-magnetic-field-induced force couple for platelet planarly alignment in a yield-stress support bath. It is hypothesized that the partial alignment induced by a directional shear force facilitates subsequent axial rotation of the platelets for planar alignment under an external force couple, resulting in a synergistic alignment effect. This sequential dual-alignment approach achieves better planar alignment of 2D modified hexagonal boron nitride (mhBN). Specifically, the thermal conductivity of the 40 wt% mhBN/epoxy composite is significantly higher (692%) than that of unaligned composites, surpassing the cumulative effect of individual methods (only 133%) with a 5 times more synergistic effect. For 30, 40, and 50 wt% mhBN composites, the thermal conductivity values (5.9, 9.5, and 13.8 W m –1 K –1 ) show considerable improvement compared to the previously reported highest values (5.3, 6.6, and 8.6 W m –1 K –1 ). Additionally, a 3D mhBN/epoxy heat sink is printed and evaluated to demonstrate the feasibility of device fabrication. The approach enables the planar alignment of electrically or thermally conducting 2D fillers during 3D fabrication.

36 MATERIALS SCIENCE↗

ORNL Campus Sustainability and Decarbonization using Waste Heat Recovery from the Oak Ridge Leadership Computing Facility’s High-Performance Computing Data Center

Heat pumps are a clean and efficient technology that can be powered by renewable electricity to transfer heat using a refrigerant from one place to another by different heat sources, making buildings clean and environmentally friendly. With the support of the ORNL Laboratory Modernization Division, this project explored and evaluated an innovative solution that uses water-water cost-effective midtemperature heat pump (MTHP) technology to leverage the low-grade waste heat from ORNL Frontier and the data center to deliver 85°C hot water, which replaces hot steam generated using natural gas combustion boilers for water heating or space heating in the buildings of ORNL campus. Two scenarios were studied. In the first scenario, which considered the 5600-5700-5800 complex only, Carrier’s commercial 1,000 kW MTHP technology achieves more than 6,640 MWh/year energy savings, an emission reduction of 858 TCO2e/year CO2, and a payback time of 4.85 years. In the second scenario, which considered the 5600-5700-5800 complex and Buildings 5100, 5200, and 5300, the CO2 emission reduction is 1,483 TCO2e/year, the operating cost savings are $0.21 million annually, and the payback time is 3.74 years. Additionally, a comprehensive HP ShowCase Tool was developed for evaluating the optimal solution to improve sustainability and decarbonization of the buildings on the ORNL campus. The tool is an Excel-based tool integrated with VBA (Visual Basic for Applications) coding. The tool includes collected ORNL campus building information and an MTHP library, which comprises collected commercial and ORNL-defined MTHPs. The tool was used to evaluate the sustainability and decarbonization of the ORNL campus. The tool can be widely used or referenced for heat pump solutions and building decarbonization renovation strategies to modernize ORNL facilities and energy use–intensive equipment to enable efficient, sustainable, and resilient operations in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Wireless Charging at Seaports for Range Extension of Drayage Battery Electric Trucks

Even though heavy-duty battery electric trucks (BETs) have become commercially available, their range limitation still hinders widespread adoption. Drayage has been regarded as a suitable application for early BETs due to typically having limited daily mileage. However, drayage operation can vary widely and some form of range extension may still be needed for BETs operating in this application. Here, in this paper, wireless charging at port terminals is proposed for this purpose. Potential wireless charging zones at port terminals are identified, and efficacy of wireless charging to extend BET range in drayage operation is verified by simulating the activity of 20 BETs from a drayage operator serving the ports of Los Angeles and Long Beach, using a microscopic BET energy consumption model. Furthermore, an optimization problem is formulated for optimal wireless charging zone planning from the port authority's perspective, considering subsets of the identified zones, and charging power options to choose from, for different budget ranges. In this context, zone planning means determining which areas of the port terminals should be selected for installing wireless charging systems, and what level of charging power should be for each selected zone's system. For each budget range, the optimization problem is solved using genetic algorithm to determine an optimal zone plan that provides the maximum amount of energy through wireless charging per unit cost of installation. The results show that wireless charging can aid improving activity completion of the simulated fleet by 5%, and further optimizing the zone plan can achieve similar performance with lower cost.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

Monolithic gas trap adsorber for high efficiency, cost effective, low-emission condensing furnace

An improved method and system for treating flue gases from a natural gas furnace are provided. The method and system include an acidic gas trap (AGT) adsorber which enables the continuous adsorption and storage of SOx, NOx redox, and formic acid/CO/HC/CH 4 oxidation, with a negligible pressure drop. The AGT adsorber includes a catalyst coating having a nanotube structure (e.g., a uniform nanostructure forest coating) or a uniform porous nanostructure of various low-cost oxides through scalable low temperature solution processes, including oxides of Ti, Cu, Ba, Mn, Zr, Zn, Sr, Ca, Li, K, Na, Al, or Ce.

Gao, Zhiming↗

Characterization and Electrochemical Analysis of Acidic Condensate-Induced Corrosion on Aluminized Coating on Steel in Residential Heaters

Condensing furnace residential heaters are starting to replace outdated and less efficient non-condensing units in homes across the US. However, the burning of natural gas in these new units produces acidic gases, which can form acid droplets (H 2 SO 4 , HNO 3 , H 2 CO 3 , etc.) that are corrosive to low-grade heat exchanger metallic materials. Type-1 aluminized steel has been used in industrial applications, such as marine, heating, and automobile parts, due to its resistance to oxidation at elevated temperature. Many components of the condensing furnaces, including heat exchangers, are made from type-1 aluminized steel. We investigated the interaction of type-1 aluminized steel substrates with two acidic condensate liquids by 500 h corrosion exposures as well as short-term electrochemical impedance measurements. SEM plan and cross-sectional view images revealed damage to the Al-Si rich layer and exposure of the steel substrate. The non-uniform damage in the Al-Si rich layer was likely attributed to a pitting corrosion mechanism and induced by high acidity of the condensate liquid. Electrochemical impedance measurements in an acidic condensate revealed lower corrosion resistance of the aluminized steel surface with a weld line, identifying welded sections as preferential corrosion initiation sites.

36 MATERIALS SCIENCE↗

Acidic Gas Reduction For Residential Natural Gas Furnace

The United States has more than 119 million homes, and 47% of them rely on natural gas as their primary heating fuel. However, most U.S. homes still use noncondensing units with an annual fuel utilization efficiency (AFUE) of ~80%, rather than efficient condensing furnaces. This is due to the high cost of condensing furnaces, which usually use expensive corrosion resistant super-ferritic stainless steel alloy heatexchangers (HX) to avoid corrosion and fouling acid condensation, along with the cost and difficulty of retrofitting the venting used by the replaced furnace. Here, this article discusses a low-cost acidic gas reduction (AGR) catalyst technology that enables a novel condensing natural gas furnace with an ultraclean (i.e., nearly zero) flue gas and neutral condensate that is environmentally friendly.

03 NATURAL GAS↗

Commercial Vehicle Electrification Evaluation Toolkit (CVEET)

The CVEET can identify and characterize charging and battery capacity challenges for class 3-8 commercial vehicle electrification, including battery electric and plug in hybrid vehicles for various trucks, vans and buses, over a wide range of vehicle operation. The tool can help build the understanding of the impact of commercial vehicle electrification on energy consumption, payload penalty, and GHG (i.e., CO2) emissions. The tool employs a quantitative approach to estimate electric vehicle energy consumption, characterize component performance and determine appropriate charging assumptions to conduct a comprehensive priority analysis of MD/HD vehicle electrification using public domain data.

Gao, Zhiming↗