Technoeconomic Studies for the Rorex Creek Pumped Storage Hydro Project: An Evaluation of New Pumped Storage Hydro in the Tennessee Valley Authority System

This report evaluates the economic viability of the proposed 1,200 MW, 23,365 MWh Rorex Creek Pumped Storage Hydro (PSH) plant that would be located near Pisgah, Alabama. In addressing this question, this study has developed processes, models and data that better value PSH from a utility perspective, more specifically a vertically integrated utility, enabling optimal PSH design and deployment. This study is designed to enhance TVA’s toolset in making PSH investment decisions and contribute to the design of a more cost-effective, stable future grid. These techniques can then be applied to a broader range of assets and utilities.

Cohen, Stuart↗

Comparative Study of Data-Driven Area Inertia Estimation Approaches on WECC Power Systems

With the increasing integration of inverter-based resources into the power grid, there has been a notable reduction in system inertia, potentially compromising frequency stability. To assess the suitability of existing area inertia estimation techniques for real-world power systems, this paper presents a rigorous comparative analysis of system identification, measurement reconstruction, and electromechanical oscillation-based area inertia estimation methodologies, specifically applied to the large-scale and multi-area WECC 240-bus power system. Comprehensive results show that the system identification-based approach exhibits superior robustness and accuracy relative to its counterparts.

area inertia estimation↗

Multi-Timescale Optimal Operation Framework for Integrated Economic and Reliability Analysis of Hybrid Power Plants

This paper introduces a hierarchical modeling framework for hybrid power plants (HPP) to facilitate the operation of HPP in power systems similar to conventional generators (Congens) in the integrated multi-timescale optimal operation framework. To consider the uncertainties of HPP renewable power in the day-ahead scheduling, distributionally robust optimization (DRO) is used. To ensure that the state-of-charge (SOC) of energy storage systems in HPPs aligns closely with the planned value for long-term reliability, real-time SOC management is incorporated. In addition, an adjustable real-time control is designed for the robust delivery of HPP real-time services. Case studies performed on a revised IEEE 39-bus system demonstrate the effectiveness of the proposed framework for HPP operation. Simulation results highlight that the proposed framework not only can help operators schedule HPP similar to Congens in varying weather conditions but can also maintain the frequency reliability of the system.

frequency stability↗

Impact of Hydrological Data on Power System Operational Studies: Preprint

Hydropower is expected to play an important role in maintaining grid reliability and flexibility as the share of of variable renewable energy increases. While the current hydropower operational models have been studied and used widely, they haven't been updated for decades to meet new performance standards. For example, current steady state and dynamic models often neglect hydrological conditions, which may lead to unrealistic expectations when relying on hydropower for energy and ancillary services. To study this impact, a multi-timescale hydrological model was created by leveraging the National Renewable Energy Laboratory-developed Multi-timescale Integrated Dynamics and Scheduling (MIDAS) tool. Using MIDAS, we compare the impact of considering hydrological conditions in a day-ahead unit commitment (DAUC) schedule on the reduced 240-bus Western Interconnect (WI) test system under winter and summer case studies. We show that neglecting current hydrological conditions of hydropower plants in power system models can lead to an overestimation of hydropower capabilities, which could lead to power balancing issues. For example, power system DAUC simulation results of our reduced test system show that in the case where hydrological conditions are not considered in the model, an approximate 31% overestimation of hydropower capabilities occurs in the summer case and approximately 60% occurs in the winter case compared to what is available. Additionally, results show an underestimation of WI day-ahead power system generation costs by approximately $54M - $80M in the weekly summer scenario and $116M - $126M in the weekly winter scenario. This analysis helps to underscore the importance of considering hydrological data in power system operational studies.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds following disturbance. To tackle this challenge, this paper proposes a frequency stability constraint for power systems unit commitment problem by considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Our developed frequency stability constraint is grounded on an analytical frequency nadir estimation framework that considers both SG and IBR dynamics. The accuracy of our frequency nadir estimation framework is validated by most severe N-1 contingency simulation result in a real island system. Then, the adaptive inertia frequency stability constraint is derived by performing sensitivity analysis with our frequency nadir estimation framework. Finally, we demonstrate the effectiveness of our developed frequency stability constraint with one year day-ahead unit commitment results of the island system.

fast frequency response↗

A Unified Analytical Method to Quantify Three Types of Fast Frequency Response from Inverter-Based Resources

With more inverter-based resources (IBRs), our power systems have lower frequency nadirs following N-1 contingencies, and undesired under-frequency load shedding (UFLS) can occur. To address this challenge, IBRs can be programmed to provide at least three types of fast frequency response (FFR), e.g., step response, proportional response (P/f droop response), and derivative response (synthetic inertia). However, these heterogeneous FFR challenge the study of power system frequency dynamics. Thus, this paper develops an analytical frequency nadir prediction method that allows for the consideration of all three potential forms of FFR provided by IBRs. The proposed method provides fast and accurate frequency nadir estimation after N-1 generation tripping contingencies. Our method is grounded on the closed-form solution for the frequency nadir, which is solved from the second-order system frequency response model considering the governor dynamics and three types of FFR. The simulation results in the IEEE 39-bus system with different types of FFR demonstrate that the proposed method provides an accurate and fast prediction of the frequency nadir under various disturbances.

fast frequency response↗

Developing Frequency Stability Constraint for Unit Commitment Problem Considering High Penetration of Renewables: Preprint

As zero-carbon electricity systems become the trend of future grid, the system inertia provided by conventional synchronous generators (SGs) keeps decreasing. The resultant lower system inertia will inevitably cause frequency stability problem, especially in the first few seconds after disturbance. To address this challenge, this paper proposes a frequency stability unit commitment constraint considering the fast frequency responses (FFRs) from inverter-based resources (IBRs). Thus, this paper first analyzes a frequency nadir differential equation that considers SG governor model and three kinds of FFR provided by IBRs. A system frequency nadir estimation framework is developed with consideration of various conventional SG and IBR models. The accuracy of this frequency estimation framework is validated by largest N-1 contingency simulation result of a real island system. Then, the adaptive inertia frequency stability unit commitment constraint is derived from sensitivity analysis method. Finally, we demonstrate the effectiveness of our developed constraints with one year day-ahead unit commitment results of the real island system.

fast frequency response↗

Distributed PV Hosting Capacity Evaluation Considering Equitable PV Accommodation

Distributed photovoltaic (DPV) hosting capacity is widely used by distribution system operators to evaluate how much DPV the distribution networks can accommodate without violating operational constraints. If the proliferation of DPV deployment is appropriately managed, it offers an excellent opportunity to mitigate the energy inequity issue in electric grids. Hosting capacity improvement plans that neglect energy equity can exacerbate unequal DPV access. To consider energy equity in distribution network planning to enhance DPV accommodation, hosting capacity evaluations should be improved to consider equity constraints endogenously. This paper proposes a DPV hosting capacity evaluation method that considers equitable DPV access among sub-regions of a distribution feeder partitioned by socioeconomic indicators, such as income level. The results demonstrate that considering equity in DPV hosting capacity evaluations can provide a valuable reference in the equitable energy transition. This work provides guidance for future distribution network upgrade planning for equitable DPV deployment.

distributed PV↗

Distributed PV Hosting Capacity Evaluation Considering Equitable PV Accommodation: Preprint

In distribution systems, distributed photovoltaic (DPV) hosting capacity is widely used by system operators to evaluate how much DPV the distribution networks can accommodate without violating operational constraints. With the proliferation of DPV deployment, if managed properly, it offers a great opportunity to mitigate the persistent energy inequity issue in electric grid. Otherwise, energy inequity can be exacerbated with unequal DPV access when hosting capacity improvement plans ignore the equity factor. To consider energy equity in distribution network planning for enhancing DPV accommodation, the hosting capacity evaluation should be improved to consider equity constraints endogenously. In this paper, a DPV hosting capacity evaluation method is proposed considering equitable DPV access among sub-regions of a distribution feeder partitioned by social-economic indicators such as the income levels. The results demonstrate that considering equity in DPV hosting capacity evaluation can provide valuable reference in the equitable energy transition. This work provides a valuable guidance for future distribution network upgrade planning for equitable DPV deployment.