Acoustic Levitation System

Dense materials, such as steel balls, continuously levitated with energy provided by efficient high-powered siren in combination with shaped reflector. Reflector system, consisting of curved top reflector and flat lower reflector, eliminates instability in spatial positioning of sample.

Gammell, P. M.

Improved Ultrasonic Resolution Via Analog Technique

High spatial resolution obtained from reflected or transmitted ultrasonic pulses by analog technique that produces signal proportional to magnitude of complex plane analytic representation of signal.

Gammell, P. M.

Dielectric Scanning Locates Voids in Glass Foam

Capacitive probes succeed where X-ray and ultrasonic equipment do not. Crossbar switching of pairs of conductors enables detection of dielectric inhomogeneities in selected small volume elements of slab of material. Large void in sample detected as low capacitance reading for volume element containing void. Applicable in nondestructive testing of other dielectric objects for internal defects that exhibit dielectric inhomogeneities.

Gammell, P. M.

Stabilized Acoustic Levitation of Dense Materials Using a High-Powered Siren

Stabilized acoustic levitation and manipulation of dense (e.g., steel) objects of 1 cm diameter, using a high powered siren, was demonstrated in trials that investigated the harmonic content and spatial distribution of the acoustic field, as well as the effect of sample position and reflector geometries on the acoustic field. Although further optimization is possible, the most stable operation achieved is expected to be adequate for most containerless processing applications. Best stability was obtained with an open reflector system, using a flat lower reflector and a slightly concave upper one. Operation slightly below resonance enhances stability as this minimizes the second harmonic, which is suspected of being a particularly destabilizing influence.

Gammell, P. M.

Hyperthermia heating apparatus

Electromagnetic energy is delivered to a localized area of a patient's body in a hyperthermic treatment so that it provides a uniform distribution of electromagnetic flux lines within the localized area of the patient's body and produces a uniform and localized heating gradient. An electrode array includes a number of electrodes which are arranged in pair, with the electrodes in each pair being spaced a particular distance apart. The array is driven by a balanced line system which is electromagnetically coupled to each pair of electrodes and which is shielded by a ground coaxial shield which itself is ground to the body of the patient. Each electrode is embedded in a Teflon stand-off in order to move the region of strong field, from the body, produced by rapidly changing potentials. The two pairs of electrodes forming a cross-like geometry are used with the balanced line systems. The electrical power is either multiplexed among the electrodes or the second pair is driven by a potential which is sinusoidal and which is 90% out of phase with the first balanced line system which is also sinusoidal.

Gammell, P. M.

Velocity and attenuation of sound in arterial tissues

The velocity of sound in excised human and canine arterial tissues is measured in order to serve as a basis for the development and application of ultrasonic techniques for the diagnosis of atherosclerotic lesions. Measurements of sound velocity at different regions of 11 human and six canine aortas were made by a time delay spectrometer technique at frequencies from 2 to 10 MHz, and compared with ultrasonic attenuation parameters and the results of biochemical assays. Sound velocity is found to increase with increasing attenuation at all frequencies, and with increasing collagen content. A strong dependence of sound velocity on cholesterol content or low calcium contents is not observed, although velocities of up to 2000 m/sec are observed in highly organized calcified lesions. A decrease in velocity with decreasing temperature is also noted. It is thus concluded that it is principally the differences in tissue collagen levels that contribute to image formation according to sound velocity.

Rooney, J. A.

Analogue implementation of analytic signal processing for pulse-echo systems

An alternative to rectification is proposed for detection of an ultrasonic signal. This method is especially useful in medical and non-destructive evaluation (nde) applications. With this method, the magnitude of the complex analytic signal is used to define the envelope of the ultrasonic waveform. The square of this quantity has been shown elsewhere to be equal to the true rate-of-arrival of energy. An earlier study, using digital data processing, has already demonstrated the superior resolvability of closely spaced interfaces obtained with the analytic signal magnitude, as compared to conventional rectification. Here, an analogue implementation is presented which utilizes single-sideband techniques to obtain both quadrature components of the analytic signal and its magnitude. A conventional transducer, pulser, and receiver are used.

Gammell, P. M.

The use of ultrasonic spectroscopy to characterize calcified lesions

A quantitative basis is developed for the medical application of ultrasonic spectroscopy, particularly in the characterization of calcified lesions associated with atherosclerotic conditions. A theory of the field radiation patterns of disk and ring sources is presented which can be used to predict minima in the reflection spectra of a target as a function of frequency and angle relative to the acoustic axis. The theory is then tested experimentally for objects of known geometry by the use of a time delay spectroscopy system using a swept frequency technique, and results are obtained which demonstrate the usefulness of the technique. Finally, the theory is verified in the determination of lesion diameter and orientation from spectra received from calcified lesions on in vitro arterial specimens as a function of angle.

Rooney, J. A.

Detection of strength limiting defects in cellular glasses by dielectric measurements

The foamed glasses that are being considered for structural support in solar thermal energy system silvered glass concentrator mirrors are assessed for strength-limiting defects by a nondestructive technique which measures the capacitance of well defined regions. The feasibility of locating large defects is demonstrated for the case of one type of cellular mass. Observed capacitance variations are believed to be due to small voids or other irregularities in the material. If the defects are equal to or greater than approximately 20 times the glass matrix pore size, they can be resolved with sufficient accuracy to delineate their spatial extent.

Gammell, P. M.

Beef grading by ultrasound

Reflections in ultrasonic A-scan signatures of beef carcasses indicate USDA grade. Since reflections from within muscle are determined primarily by fat/muscle interface, richness of signals is direct indication of degree of marbling and quality. Method replaces subjective sight and feel tests by individual graders and is applicable to grade analysis of live cattle.

Gammell, P. M.

Improved ureteral stone fragmentation catheter

Catheter includes fiber optic viewer, more reliable ultrasonic probe, and better contact sensor. It is guided by four steering wires, and irrigation fluid is supplied through lumen to remove stone fragments.

Gammell, P. M.

Application of imaging and ultrasound to the quality grading of beef

The results of a study conducted to assist the Department of Agriculture in the task of considering innovative methods for the grading of carcass beef for human consumption is presented. The processing of photographic, television and ultrasound images of the longissimus dorsi muscle at the 12/13th rib cut was undertaken. The results showed that a correlation could be developed between the quality grade of the carcass as determined by a professional grader, and the fat to area ratio of the muscle as determined by image processing techniques. In addition, the use of ultrasound shows the potential for grading of an unsliced carcass or a live animal.

Anselmo, V. J.

Temperature and frequency dependence of ultrasonic attenuation in selected tissues

Ultrasonic attenuation over the frequency range of 1.5-10 MHz has been measured as a function of temperature for porcine liver, backfat, kidney and spleen as well as for a single specimen of human liver. The attenuation in these excised specimens increases nearly linearly with frequency. Over the temperature range of approximately 4-37 C the attenuation decreases with increasing temperature for most soft tissue studied.

Gammell, P. M.

Tissue identification by ultrasound

The ultrasonic properties of animal and human soft tissue were measured over the frequency range of 1.5 to 10.0 MHz. The method employed a swept-frequency, coherent technique known as time delay spectrometry. Measurements of attenuation versus frequency on liver, backfat, kidney, pancreas, spleen, breast, and other tissue were made. Considerable attention was paid to tissue handling and in determining the effects of fixing on the attenuation of ultrasound in the tissue.

Lecroissette, D. H.

Signal processing in ultrasound

Signal is the term used to denote the characteristic in the time or frequency domain of the probing energy of the system. Processing of this signal in diagnostic ultrasound occurs as the signal travels through the ultrasonic and electrical sections of the apparatus. The paper discusses current signal processing methods, postreception processing, display devices, real-time imaging, and quantitative measurements in noninvasive cardiology. The possibility of using deconvolution in a single transducer system is examined, and some future developments using digital techniques are outlined.

Le Croissette, D. H.