Engineering Papers⌕ Search

Engineering topics

Gaier, Todd

Publications and source records attributed to Gaier, Todd.

45 records · Page 3

MCM Polarimetric Radiometers for Planar Arrays

A polarimetric radiometer that operates at a frequency of 40 GHz has been designed and built as a prototype of multiple identical units that could be arranged in a planar array for scientific measurements. Such an array is planned for use in studying the cosmic microwave background (CMB). All of the subsystems and components of this polarimetric radiometer are integrated into a single multi-chip module (MCM) of substantially planar geometry. In comparison with traditional designs of polarimetric radiometers, the MCM design is expected to greatly reduce the cost per unit in an array of many such units. The design of the unit is dictated partly by a requirement, in the planned CMB application, to measure the Stokes parameters I, Q, and U of the CMB radiation with high sensitivity. (A complete definition of the Stokes parameters would exceed the scope of this article. In necessarily oversimplified terms, I is a measure of total intensity of radiation, while Q and U are measures of the relationships between the horizontally and vertically polarized components of radiation.) Because the sensitivity of a single polarimeter cannot be increased significantly, the only way to satisfy the high-sensitivity requirement is to make a large array of polarimeters that operate in parallel. The MCM includes contact pins that can be plugged into receptacles on a standard printed-circuit board (PCB). All of the required microwave functionality is implemented within the MCM; any required supporting non-microwave ("back-end") electronic functionality, including the provision of DC bias and control signals, can be implemented by standard PCB techniques. On the way from a microwave antenna to the MCM, the incoming microwave signal passes through an orthomode transducer (OMT), which splits the radiation into an h + i(nu) beam and an h - i(nu) beam (where, using complex-number notation, h denotes the horizontal component, nu denotes the vertical component, and +/-i denotes a +/-90deg phase shift). Each of these beams enters the MCM through one of two WR-22 waveguide input terminals in the lid of the MCM. The h + i(nu0 and h - i(nu) signals are amplified, then fed to a phase-discriminator hybrid designed specifically to fit the predominantly planar character of the MCM geometry and to enable determination of Q and U. The phase-discriminator hybrid generates four outputs, which are detected and used to calculate I, Q, and U.

Kangaslahti, Pekka↗

MMIC Amplifier Produces Gain of 10 dB at 235 GHz

The first solid-state amplifier capable of producing gain at a frequency >215 GHz has been demonstrated. This amplifier was fabricated as a monolithic microwave integrated-circuit (MMIC) chip containing InP high-electron-mobility transistors (HEMTs) of 0.07 micron gate length on a 50- m-thick InP substrate.

Dawson, Douglas↗

GeoSTAR : developing a new payload for GOES satellites

The Geostationary Synthetic Thinned Aperture Radiometer (GeoSTAR) is a new concept for a microwave sounder, intended to be deployed on NOAA's next generation of geostationary weather satellites, the GOES-R series - due to first launch in 2012. This will fill a serious gap in OW remote sensing capabilities of long standing - a key capability that NOAA is book keeping at the top of its list of 'pre-planned product improvements' for GOES-R - i.e. the most urgently needed additional payload, which will be added as soon as funding has been allocated and programmatic issues resolved. Although real-aperture GEO microwave sounders have been proposed over the years, only GeoSTAR is capable of meeting the measurement requirements and is therefore now the leading candidate.

microwave↗

GeoSTAR - A Microwave Sounder for Geostationary Satellites

GeoSTAR represents a new approach to microwave atmospheric sounding that is now under development. It has capabilities similar to sensors currently operating on low earth orbiting weather satellites but is intended for deployment in geostationary orbit - where it will complement future infrared sounders and enable all-weather temperature and humidity soundings and rain mapping. The required spatial resolution of 50 km or better dictates an aperture of 4 meters or more at a sounding frequency of 50 GHz, which is difficult to achieve with a real aperture system - this is the reason why it has until now not been possible to put a microwave sounder on a geostationary platform. GeoSTAR is instead based on a synthetic aperture imaging approach. Among the advantages of such a system are that there are no moving parts, and the size of the aperture is easily expandable to meet future needs. A ground based prototype of GeoSTAR is currently under development in an effort led by the Jet Propulsion Laboratory.

aperture synthesis↗

High-Performance Solid-State W-Band Power Amplifiers

The figure shows one of four solid-state power amplifiers, each capable of generating an output power greater than or equal to 240 mW over one of four overlapping frequency bands from 71 to 106 GHz. (The bands are 71 to 84, 80 to 92, 88 to 99, and 89 to 106 GHz.) The amplifiers are designed for optimum performance at a temperature of 130 K. These amplifiers were developed specifically for incorporation into frequency-multiplier chains in local oscillators in a low-noise, far-infrared receiving instrument to be launched into outer space to make astrophysical observations. The designs of these amplifiers may also be of interest to designers and manufacturers of terrestrial W-band communication and radar systems. Each amplifier includes a set of six high-electron-mobility transistor (HEMT) GaAs monolithic microwave integrated-circuit (MMIC) chips, microstrip cavities, and other components packaged in a housing made from A-40 silicon-aluminum alloy. This alloy was chosen because, for the original intended spacecraft application, it offers an acceptable compromise among the partially competing requirements for high thermal conductivity, low mass, and low thermal expansion. Problems that were solved in designing the amplifiers included designing connectors and packages to fit the available space; designing microstrip signal-power splitters and combiners; matching of impedances across the frequency bands; matching of the electrical characteristics of those chips installed in parallel power-combining arms; control and levelling of output power across the bands; and designing the MMICs, microstrips, and microstrip cavities to suppress tendencies toward oscillation in several modes, both inside and outside the desired frequency bands.

Gaier, Todd↗

Amplifier arrays for CMB polarization

Cryogenic low noise amplifier technology has been successfully used in the study of the cosmic microwave background (CMB). MMIC (Monolithic Millimeter wave Integrated Circuit) technology makes the mass production of coherent detection receivers feasible.

CMB↗

On-Wafer Testing of Circuits Through 220 GHz

We have jointly developed the capability to perform on-wafer s-parameter and noise figure measurements through 220 GHz. S-parameter test sets have been developed covering full waveguide bands of 90-140 GHz (WR-08) and 140-220 GHz (WR-05). The test sets have been integrated with coplanar probes to allow accurate measurements on-wafer. We present the design and performance of the test sets and wafer probes. We also present calibration data as well as measurements of active circuits at frequencies as high as 215 GHz.

Gaier, Todd↗

Cosmic background radiation anisotropy at degree angular scales - Further results from the South Pole

We report further results from the University of California at Santa Barbara program to measure anisotropy in the cosmic background radiation at angular scales near 1 deg, an angular range corresponding to the largest scales where structure is observed. A 30 GHz high electron mobility transistor amplifier-based detector was coupled to the Advanced Cosmic Microwave Explorer, a 1 m off-axis Gregorian telescope. We present data that represent 64 of the total of 500 hr acquired with this system during the 1990-1991 season. The data have a statistical error of 13.5/micro-K/pixel. These are the smallest error bars of any data set of this type published to date. The data contain a significant signal with a maximum likelihood Delta T/T roughly 1 x 10 exp -5. The spectrum of the signal seen in slightly less than 2 sigma away from the thermal spectrum expected of primordial fluctuations in the cosmic background radiation. If the source of the fluctuations is primordial, then the data are consistent with cold dark matter scenarios when normalized to the large-scale anisotropy observed by COBE, while if the origin of the signal is foreground emission or another form of contaminant then the data are marginally inconsistent with standard cold dark matter models. In either case, the data are sufficiently sensitive to provide a crucial test of many models.

Schuster, Jeffrey↗

A degree-scale measurement of anisotropy of the cosmic background radiation

We report on the preliminary result of a search for anisotropy in the cosmic background radiation (CBR) with a beam size of about 1.5 deg FWHM over a wavelength range of 8-12 mm. The system operated successfully for 500 hr at the South Pole during the 1990-1991 austral summer. The data from one region, representing 25 hr after editing, are presented here. A strong signal is present in the lower frequency channels with a spectrum unlike CBR fluctuations, and is probably due to foreground emission. The highest frequency channel has the smallest contribution from this signal and has been used to set a 95-percent confidence level upper limit of not greater than 1.4 x 10 exp -5 for fluctuations with a Gaussian autocorrelation function at a coherence angle of 1.2 deg. This is significantly more sensitive than previous experiments at this angle scale.

Gaier, Todd↗