Engineering PapersSearch

Engineering topics

Gaetz, T. J.

Publications and source records attributed to Gaetz, T. J..

Orbital Verification of the CXO High-Resolution Mirror Assembly Alignment and Vignetting

Prior to launch, the High Resolution Mirror Assembly (HRMA) of the Chandra X-ray Observatory underwent extensive ground testing at the X-ray Calibration Facility (XRCF) at the Marshall Space Flight Center in Huntsville. Observations made during the post-launch Orbital Activation and Calibration period, allow the on-orbit condition of the X-ray optics to be assessed. Based on these ground-based and on-orbit data, we examine the alignment of the x-ray optics based on the PSF, and the boresight and alignment of the optical axis alignment relative to the detectors. We examine the vignetting and the single reflection ghost suppression properties of the telescope. Slight imperfections in alignment lead to a small azimuthal dependence of the off-axis area; the morphology of off-axis images also shows an additional small azimuthal dependence varying as 1/2 the off-axis azimuth angle.

Gaetz, T. J.

Orbital Measurement and Verification of the Chandra X-Ray Observatory's PSF

The recently launched Chandra x-ray Observatory (CXO) was designed to have the sharpest angular resolution yet of any x-ray telescope. Detailed modeling and metrology of the optics followed by extensive testing at the X-ray Calibration Facility at the Marshall p Space Flight Center in Huntsville, Alabama, indicated that the optics were performing exceedingly well, within our ability to account for distortion of the mirrors due to gravity, and the effects of finite distance and size of the x-ray generator. Thus it was only on-orbit that we expected to directly observe the specified half arcsecond performance. We present here results of the on-orbit calibration of the point spread function (PSF), comparing it with our predictions. We discuss how the PSF varies with source location in the telescope field of view, as well as with the spectral energy distribution of the source.

Jerius, D.

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.

Predictions of the On-Orbit Performance of AXAF's Optics

The AXAF optics and science instruments have recently undergone a battery of tests at the Marshall Space Flight Center X-Ray Calibration Facility to determine their spatial and spectral performance. We have combined these data, detailed maps of the optics, surfaces, precise measurements of surface roughness and reflectivity, and detailed mechanical models of the optics and their support structures to arrive at predictions of the optics' on-orbit performance. We present on- and off-axis effective areas, encircled energies, and PSFS.

Jerius, D.

AXAF-I ghost ray study: On orbit case

The problem of baffles for control of singly reflected (and nonreflected) ghost rays is considered. The theory of baffle design for Wolter Type I grazing incidence optics is reviewed, and a set of sample baffle parameters is obtained subject to the assumptions of nominal mirror figures and perfect manufacture and alignment of baffles. It is found that baffles forward of the optics (in the thermal precollimator) and between the mirror elements (at the CAP) are sufficient to allow the simultaneous ghost image and vignetting requirements to be satisfied for HRMA shells P1H1, P3H3, and P4H4. However, these baffles are not sufficient for the innermost shell P6H6; at best the requirements are slightly violated and there is no margin for tolerances. The addition of a baffle interior to the P6 space at an axial station about one third of the way forward from the aft end of the paraboloid will allow the ghost ray and vignetting requirements to be met. The minimum ghost ray angles and the vignetting angles are sensitive functions of the baffle positions and radii; tolerances of considerably better than 1 mm will be required. The sensitivities are coupled and correlated; further investigations should be undertaken in order to obtain baffle parameters which, combined with likely achievable tolerances, will minimize the risk of the vignetting/ghost ray requirements not being met. The lightweight carbon-epoxy composite used for thermal baffles has insufficient X-ray opacity to be a suitable material for construction of the controlling X-ray baffles; further study is needed to determine an appropriate material and to investigate its thermal and mechanical implications.

Gaetz, T. J.

Stability of radiative shocks with time-dependent cooling

A full evolutionary calculation of ion abundances and radiative cooling has been incorporated into an accurate one-dimensional gasdynamics calculation in order to investigate the dynamics of radiative shock instability and to determine the extent to which power-law cooling models describe the situation. Radiative shocks are shown to be unstable for velocities of greater than about 140 km/s. The temperature dependence of cooling functions behind steady shocks suggests that the stability limit may depend upon the amplitude of the perturbation. Oscillation is noted in the fundamental oscillation mode.

Gaetz, T. J.