Engineering Papers⌕ Search

Engineering topics

Furukawa, K

Publications and source records attributed to Furukawa, K.

Absolute energy calibration of FD by an electron linear accelerator for Telescope Array

The primary energy of the ultra-high energy cosmic rays(UHECR) are measured with the number of fluorescence photons which are detected with fluorescence detectors(FD) in the Telescope Array experiment(TA). Howevery since there is large uncertinty as 19% in the measurement of the energy scale, the most important theme is improvement of the energy calibration. The electron light source(ELS) is a small electron linear accelerator for new energy calibration. The ELS is located 100 m far from the FD station, and injects electron beam which is accelerated to 40 MeV energy into the sky. We can calibrate the FD energy scale by detection the air shower directly which is generated by the electron beam. The ELS was developed in KEK Japan, and moved to the TA site in March 2009. We started the beam operation in September 2010, in consequence we detected the air shower which was generated by electron beam in the air. The output kinetic energy of the electron beam was 41.1 MeV, we adjusted the output charge from 40 to 140 pC/pulse. We expect that we can improve the uncertinty of the energy scale to about 10% with the ELS, futhermore ELS will be a very useful apparatus for R and D of future UHECR observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New beam-charge interlock system for radiation safety at the KEKB injector linac

A new beam-charge interlock system is under development for radiation safety and machine protection at the KEKB injector linac. A hardware-based interlock system is required instead of the present software-based interlock system in order to boost its reliability. This system restricts the integrated amount of beam charges delivered to four different storage rings. The beam charges are measured using wall-current monitors and detection electronics at six locations along the linac. The detection electronics independently transmits a beam-abort request through a twisted hardwire cable directly to the safety control system of the linac, when the integrated amount of beam charges exceeds a certain threshold level prescribed for each location. We describe the characteristics and performance of the new beam-charge interlock system along with the details of the experimental tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ILC global control system.

The scale and performance parameters of the ILC require new thinking in regards to control system design. This design work has begun quite early in comparison to most accelerator projects, with the goal of uniquely high overall accelerator availability. Among the design challenges are high control system availability, precision timing and rf phase reference distribution, standardizing of interfaces, operability, and maintainability. We present the current state of the design and take a prospective look at ongoing research and development projects.

43 PARTICLE ACCELERATORS↗