A novel occupancy detection solution using low-power IR-FPA based wireless occupancy sensor

Significant energy savings can be achieved by operating heating, ventilation, and air conditioning control systems with indoor occupancy measurement information. This paper presents a novel plug-and-play occupancy sensing method which will enable temporal minimization of building energy consumption to meet building usage behavior without privacy concerns. The proposed wireless occupancy sensing platform is based on long-wave infra-red (LWIR) focal-plane arrays (FPAs), or thermal imagers, that detect thermal energy rather than visible light. We developed an advanced sensor package consisting of multiple thermal imagers with low-cost optical enhancements to increase field of view and increase sensitivity to occupant detection (filtering building clutter). These imagers can be coupled with radio frequency and ultrasonic-based radar to enhance data collection at key occupant zone boundaries to improve accuracy. Standard filtering and estimation techniques from the image processing and computer vision communities are introduced to overcome the accuracy issues suffered by traditional PIR based sensing, especially when occupants remain relatively still. Accurate low-level counting of individuals can be achieved with minimal impact on privacy. As a result, the proposed occupancy detection method can work as a retrofit to enable real-time understanding of the building operational state and usage behavior. Sensor data obtained from real test building zones was used to test the efficacy of the method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

VOLTTRON-enabled Home Energy Management System

Home Energy Management Systems (HEMS) consist of software and hardware systems that provide communication, control, and management among different electronic devices, such as heating, ventilation, and air-conditioning (HVAC) systems. HEMS are a growing market sector in the era of smart grids and smart homes. HEMS can help both homeowners and utilities save money and energy by monitoring and controlling smart devices in a house. Based on the Department of Energy (DOE) Building Energy Data Book, 41% of the energy consumed in the United States is used by buildings (see Figure 1). This shows the importance of saving energy in the building sector. This report introduces two approaches that existing HEMS vendors can use to leverage VOLTTRON as their control and interoperability engine. The goal of this project is to make open-source, user-friendly HEMS available to the market so that everyone can benefit from them. The HEMS introduced as a result of this study should satisfy HEMS specifications such as device monitoring and control, seamless communication between devices, DR, intelligence, data management, and security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Templated Approach for Multi-Physics Modeling of Hybrid Energy Systems in Modelica

A prototypical hybrid energy system (HES) couples a primary thermal power generator (i.e., nuclear power plant) with one or more additional subsystems beyond the traditional balance of plant electricity generation system. The definition and architecture of an HES can be adapted based on the needs and opportunities of a given local market. For example, locations in need of potable water may be best served by coupling a desalination plant to the HES. A location near an oil refinery may have a need for emission-free hydrogen production. The flexible, multidomain capabilities of Modelica are being used to investigate the dynamics (e.g., thermal hydraulics and electrical generation/consumption) of such a hybrid system. This paper examines the simulation infrastructure created to enable the coupling of multiphysics subsystem models for HES studies. A demonstration of a tightly coupled nuclear hybrid energy system implemented using the Modelica based infrastructure is presented for two representative cases. An appendix is also included providing a step-by-step procedure for using the template-based infrastructure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Non-Intrusive Energy Disaggregation Using Non-Negative Matrix Factorization With Sum-to-k Constraint

Energy disaggregation or non-intrusive load monitoring addresses the issue of extracting device-level energy consumption information by monitoring the aggregated signal at one single measurement point without installing meters on each individual device. Energy disaggregation can be formulated as a source separation problem, where the aggregated signal is expressed as linear combination of basis vectors in a matrix factorization framework. In this paper, an approach based on Sum-to-k constrained non-negative matrix factorization (S2K-NMF) is proposed. By imposing the sum-to-k constraint and the non-negative constraint, S2K-NMF is able to effectively extract perceptually meaningful sources from complex mixtures. The strength of the proposed algorithm is demonstrated through two sets of experiments: Energy disaggregation in a residential smart home; and heating, ventilating, and air conditioning components energy monitoring in an industrial building testbed maintained at the Oak Ridge National Laboratory. Furthermore, extensive experimental results demonstrate the superior performance of S2K-NMF as compared to state-of-the-art decomposition-based disaggregation algorithms.