Engineering PapersSearch

Engineering topics

Froidevaux, L.

Publications and source records attributed to Froidevaux, L..

At least 55 records · Page 3

MLS Observations of Arctic Ozone Loss in 1996-1997

The Microwave Limb Sounder (MLS) observed ozone (O3) loss in the Arctic vortex beginning in January 1997 at 585 K (approximately 25 hPa) and in February 1997 at 465 K (approximately 50 hPa). Minimum vortex-averaged O3 mixing ratios observed in 1997 were higher than those in 1996, which were the lowest ever recorded by MLS. The vertical extent of O3 loss and maximum local O3 decreases were larger, but the decrease filled the vortex less completely, in 1997 than in 1996. Unusually low high-latitude column O3 above 100 hPa in April 1997 resulted mainly from dynamical effects of the unusually persistent lower stratospheric vortex and winter-like temperature patterns. Column O3 above 100 hPa averaged in comparable regions of the vortex showed a stronger decreasing trend in 1996-97 than in 1995-96, consistent with the larger vertical extent and maximum local values of lower stratospheric O3 loss. Chemical O3 loss resulted in an approximately 10% observed decrease in column O3 between late January and early April 1997.

Manney, G. L.

The 4-Day Wave as Observed from the Upper Atmosphere Research Satellite Microwave Limb Sounder

The "4-day wave" is an eastward moving quasi-nondispersive feature with period near 4 days occurring near the winter polar stratopause. This paper presents evidence of the 4-day feature in Microwave Limb Sounder (MLS) temperature, geopotential height, and ozone data from the late southern winters of 1992 and 1993. Space-time spectral analyses reveal a double-peaked temperature structure consisting of one peak near the stratopause and another in the lower mesosphere, with an out-of-phase relationship between the two peaks. This double- peaked structure is reminiscent of recent three-dimensional barotropic/baroclinic instability model predictions and is observed here for the first time. The height variation of the 4-day ozone signal is shown to compare well with a linear advective-photochemical tracer model. Negative regions of quasigeostrophic potential vorticity (PV) gradient and positive Eliassen-Palm flux divergence are shown to occur, consistent with instability dynamics playing a role in wave forcing. Spectral analyses of PV derived from MLS geopotential height fields reveal a 4-day signal peaking near the polar stratopause. The three-dimensional structure of the 4-day wave resembles the potential vorticity "charge" concept, wherein a PV anomaly in the atmosphere (analogous to an electrical charge in a dielectric material) induces a geopotential field, a vertically oriented temperature dipole, and circulation about the vertical axis.

Allen, D. R.

Polar Vortex Conditions During The 1995-96 Arctic Winter: MLS ClO and HNO3

Microwave Limb Sounder (MLS) measurements of lower stratospheric ClO and HNO3 during the 1995-96 Arctic winter are presented. The 1995-96 Arctic winter was both colder and more persistently cold than usual, leading to an enhancement in lower stratospheric ClO of greater magnitude, vertical extent, and duration than previously observed in the Arctic. Vortex concentrations of HNO3 in mid-December were large due to diabatic descent. Trajectory calculations indicate that localized severe depletions of gas-phase HNO3 in mid-February and early March did not arise from entrainment of midlatitude air into the vortex and were therefore probably related to polar stratospheric cloud (PSC) formation. A strong correlation between temperature and gas-phase HNO3 was evident, consistent with recurring PSC condensation and evaporation cycles.

Santee, M. L.

Polar Vortex Conditions during the 1995-96 Artic Winter: Meteorology and MLS Ozone

The 1995-96 northern hemisphere (NH) 205 winter stratosphere was colder than in any of the previous 17 winters, with lower stratospheric temperatures continuously below the type 1 (primarily HN03) polar stratospheric cloud (PSC) threshold for over 2 1/2 months. Upper tropospheric ridges in late Feb and early Mar 1996 led to the lowest observed NH lower stratospheric temperatures, and the latest observed NH temperatures below the type 2 (water ice) PSC threshold. Consistent with the unusual cold and chemical processing on PSCS, Upper Atmosphere Research Satellite (UARS) MLS observed a greater decrease in lower stratospheric ozone (03) in 1995-96 than in any of the previous 4 NH winters. 03 decreased throughout the vortex over an altitude range nearly as large as that typical of the southern hemisphere (SH). The decrease between late Dec 1995 and early Mar 1996 was about 2/3 of that over the equivalent SH period. As in other NH winters, temperatures in 1996 rose above the PSC threshold before the spring equinox, ending chemical processing in the NH vortex much earlier than is usual in the SH. A downward trend in column 03 above 100 hPa during Jan and Feb 1996 appears to be related to the lower stratospheric 03 depletion.

Manney, G. L.

Chlorine Deactivation in the Lower Stratospheric Polar Regions during late Winter: Results from UARS

Recovery from enhanced chlorine conditions in the lower stratospheric polar regions of both hemispheres is investigated using data from the Upper Atmosphere Research Satellite (UARS). Microwave Limb Sounder (MLS) measurements of ClO within the polar vortices are used to infer ClO(sub x) (ClO + 2Cl202) abundances that are then correlated with simultaneous Cryogenic Limb Array Etalon Spectrometer (CLAES) measurements of ClON02 and Halogen Occultation Experiment (HALOE) measurements of HCl obtained starting within 5 days of the end of the MLS and CLAES high-latitude observing periods in each hemisphere. Time series of vortex-averaged mixing ratios are calculated on two potential temperature surfaces (585 K and 465 K) in the lower stratosphere for approximately month-long intervals during late winter: August 17 - September 17, 1992, in the southern hemisphere and February 12 - March 16, 1993, in the northern hemisphere. The observed mixing ratios are adjusted for the effects of vertical transport using diabatic vertical velocities estimated from CLAES tracer data. In the northern hemisphere, the decrease in ClO, is balanced on both surfaces by an increase in ClON02- In the southern hemisphere, continuing polar stratospheric cloud activity prevents ClO from undergoing sustained decline until about September 3. In contrast to the northern hemisphere, there is no significant chemical change in vortex-averaged ClON02 at 465 K, and there is an apparent decrease in ClON02 at 585 K, even after the enhanced ClO abundances have started to recede. Results from the SLIMCAT chemical transport model initialized with UARS data and run with OH + ClO yields HCl + 02 as an 8% channel suggest that the primary recovery product in the south during this time period is not ClON02, but HCl. HALOE HCl mixing ratios are extrapolated back to the time of the MLS and CLAES data. At 585 K, the chlorine budget can be made to balance by extrapolating HCl back to a value of 0.6 parts per billion by volume (ppbv) at the beginning of the study period; at 465 K, the contribution from extrapolated HCl is not sufficient to offset the loss in ClOx, and there is a slight imbalance between the decrease in reactive chlorine and the change in chlorine reservoirs. The difficulty in closing the chlorine budget in the southern hemisphere may arise from complications caused by ongoing activation, incomplete photochemical assumptions, and/or inadequate data quality.

Santee, M. L.

Validation of UARS Microwave Limb Sounder Temperature and Pressure Measurements

The accuracy and precision of the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) atmospheric temperature and tangent-point pressure measurements are described. Temperatures and tangent- point pressure (atmospheric pressure at the tangent height of the field of view boresight) are retrieved from a 15-channel 63-GHz radiometer measuring O2 microwave emissions from the stratosphere and mesosphere. The Version 3 data (first public release) contains scientifically useful temperatures from 22 to 0.46 hPa. Accuracy estimates are based on instrument performance, spectroscopic uncertainty and retrieval numerics, and range from 2.1 K at 22 hPa to 4.8 K at 0.46 hPa for temperature and from 200 m (equivalent log pressure) at 10 hPa to 300 m at 0.1 hPa. Temperature accuracy is limited mainly by uncertainty in instrument characterization, and tangent-point pressure accuracy is limited mainly by the accuracy of spectroscopic parameters. Precisions are around 1 K and 100 m. Comparisons are presented among temperatures from MLS, the National Meteorological Center (NMC) stratospheric analysis and lidar stations at Table Mountain, California, Observatory of Haute Provence (OHP), France, and Goddard Spaceflight Center, Maryland. MLS temperatures tend to be 1-2 K lower than NMC and lidar, but MLS is often 5 - 10 K lower than NMC in the winter at high latitudes, especially within the northern hemisphere vortex. Winter MLS and OHP (44 deg N) lidar temperatures generally agree and tend to be lower than NMC. Problems with Version 3 MLS temperatures and tangent-point pressures are identified, but the high precision of MLS radiances will allow improvements with better algorithms planned for the future.

Fishbein, E. F.

Validation of UARS Microwave Limb Sounder Ozone Measurements

This paper describes the validation of ozone data from the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS). The MLS ozone retrievals are obtained from the calibrated microwave radiances (emission spectra) in two separate bands, at frequencies near 205 and 183 GHz. Analyses described here focus on the MLS Version 3 data (the first set of files made publicly available). We describe results of simulations performed to assess the quality of the retrieval algorithms, in terms of both mixing ratio and radiance closure. From actual MLS observations, the 205-GHz ozone retrievals give better closure (smaller radiance residuals) than that from the 183-GHz measurements and should be considered more accurate from the calibration aspects. However, the 183-GHz data are less noise limited in the mesosphere and can provide the most useful scientific results in that region. We compare the retrieved 205-GHz ozone profiles in the middle-to lower stratosphere to ozonesonde measurements at a wide range of latitudes and seasons. Ground-based lidar data from Table Mountain, California, provide a good reference for comparisons at higher altitudes. Based on these analyses, comparisons with balloon-borne measurements and others, as well as a detailed budget of estimated uncertainties, MLS results appear to be generally of high quality, with some biases worth mentioning. Results for the lowermost stratosphere (approx. 50 to 100 bPa) are still in need of improvement. A set of estimated precision and accuracy values is derived for the MLS ozone data sets. We also comment on recent updates in the retrieval algorithms and their impact on ozone values.

Froidevaux, L.

Validation of UARS Microwave Limb Sounder ClO Measurements

Validation of stratospheric ClO measurements by the Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is described. Credibility of the measurements is established by (1) the consistency of the measured ClO spectral emission line with the retrieved ClO profiles and (2) comparisons of ClO from MLS with that from correlative measurements by balloon-based, ground-based, and aircraft-based instruments. Values of "noise" (random), "scaling" (multiplicative), and "bias" (additive) uncertainties are determined for the Version 3 data, in the first version public release of the known artifacts in these data are identified. Comparisons with correlative measurements indicate agreement to within the combined uncertainties expected for MLS and the other measurements being compared. It is concluded that MLS Version 3 ClO data, with proper consideration of the uncertainties and "quality" parameters produced with these data, can be used for scientific analyses at retrieval surfaces between 46 and 1 hPa (approximately 20-50 km in height). Future work is planned to correct known problems in the data and improve their quality.

Waters, J. W.

Validation of UARS Microwave Limb Sounder 183 GHz H2O Measurements

The Upper Atmosphere Research Satellite (UARS) microwave limb sounder (MLS) makes measurements of thermal emission at 183.3 GHz which are used to infer the concentration of water vapor over a pressure range of 46-0.2hPa (approximately 20-60 km). We provide a validation of MLS H2O by analyzing the integrity of the measurements, by providing an error characterization, and by comparison with data from other instruments. It is estimated that version 3 MLS H2O retrievals are accurate to within 20-25% in the lower stratosphere and to within 8-13% in the upper stratosphere and lower mesosphere. The precision of a single profile is estimated to be approximately 0.15 parts per million by volume (ppmv) in the midstratosphere and 0.2 ppmv in the lower and upper stratosphere. In the lower mesosphere the estimate of a single profile precision is 0.25-0.45 ppmv. During polar winter conditions, H2O retrievals at 46 hPa can have a substantial contribution from climatology. The vertical resolution of MLS H2O retrievals is approximately 5 km.

Lahoz, W. A.

Arctic Ozone Depletion Observed by UARS MLS During the 1994-95 Winter

During the unusually cold 1994-95 Arctic winter, the Microwave Limb Sounder observed enhanced chlorine monoxide (ClO) in late Dec and throughout Feb and early Mar. Late Dec ClO was higher than during any of the previous 3 years, consistent with the colder early winter. Between late Dec 1994 and early Feb 1995, 465 K (about 50 hPa) vortex-averaged ozone (03) decreased by about 15%, with local decreases of about 30%; additional local decreases of about 5% were seen between early Feb and early Mar. Transport calculations indicate that vortex-averaged chemical loss between late Dec and early Feb was about 20% at 465 K, with about 1/4 of that masked by downward transport of O3. This Arctic chemical O3 loss is not readily detectable in MLS column O3 data.

Manney, G. L.

Validation of UARS MLS 183 GHz H(sub 2)O Measurements

We provide a validation of MLS H(sub 2)O by analyzing the integrity of the measurements, by providing an error characterization and by comparison with data from other instruments. This paper concerns the data validation of middle atmosphere distributions of H(sub 2)O as measured by the Midrowave Limb Sounder (MLS).

thermal emission UARS energy balance of the middle

Polar Vortex Conditions During the 1995-96 Arctic Winter: MLS CL0 and HNO(sub 3)

Microwave Limb Sounder (MLS) measurements of lower stratospheric CLO and HNO(sub 3) during the 1995-96 Arctic winter are presented. The 1995-96 Arctic winter was both colder and more persistently cold than usual, leading to an enhancement in lower stratospheric CLO of greater magnitude, vertical extent, and duration than has been previously observed in the Arctic. Vortex concentrations of HNO(sub 3) in mid-December were large due to diabetic decent. Trajectory calculations indicate that localized severe depletions of gas-phase HNO(sub 3) in mid-February and early March did not arise from intrainment of midlatitude air into the vortex and were therefore probably related to polar stratospheric cloud (PSC) formation.

Microwave Limb Sounder MLS CLO HNO3

Polar Vortex Conditions During the 1995-96 Artic Winter: Meteorology and MLS Ozone

The 1995-96 northern hemisphere (NH) winter was colder than any of the previous 17 NH winters, with temperatures continuously below the type 1 polar stratospheric cloud (PSC) threshold for over 2 1/2 months; upper tropospheric ridges in late Feb and early Mar 1996 led to the lowest observed NH winter lower stratospheric temperatures, and the latest observation of HN temperatures below the type 2 PSC threshold.

arctic