Engineering Papers⌕ Search

Engineering topics

Frisch, Henry

Publications and source records attributed to Frisch, Henry.

Energy and flavor discrimination using precision time structure in on-axis neutrino beams

We propose to use a higher-frequency rf bunch structure for the primary proton beam on target and precision timing to select different energy and flavor spectra from a wide-band neutrino beam, based on the relative arrival times of the neutrinos with respect to the rf bunch structure. This “stroboscopic” approach is complementary to techniques that select different neutrino energy spectra based on the angle with respect to the beam axis. A timing-based approach allows for the selection of varying energy spectra from the same on-axis detector, and applies equally to both the near and far detectors in an oscillation experiment. Energy and flavor discrimination of neutrinos produced by hadrons in-flight will require proton bunch lengths on the order of 100 ps and commensurate time resolution in the detector. Correlating neutrino events with the parent proton interaction is currently limited by the nanosecond-scale width of the proton bunches impinging on the target. We show that these limitations can be addressed by using a superconducting rf cavity to rebunch the present 53.1 MHz rf bunch structure with a factor of 10 higher rf frequency, thus attaining the required shorter bunch length.

43 PARTICLE ACCELERATORS↗

Use of flat panel microchannel photomultipliers in sampling calorimeters with timing

Large-area, flat-panel photo-detectors with sub-nanosecond time resolution based on microchannel plates are provided. The large-area, flat-panel photo-detectors enable the economic construction of sampling calorimeters with, for example, enhanced capability to measure local energy deposition, depth-of-interaction, time-of-flight, and/or directionality of showers. In certain embodiments, sub-nanosecond timing resolution supplies correlated position and time measurements over large areas. The use of thin flat-panel viewing radiators on both sides of a radiation-creating medium allows simultaneous measurement of Cherenkov and scintillation radiation in each layer of the calorimeter. The detectors may be used in a variety of applications including, for example, medical imaging, security, and particle and nuclear physics.

Frisch, Henry↗

Secondary Emission Calorimeter (SEC)

This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) the experimenters of University of Chicago and California Institute of Technology, who have committed to participate in beam tests to be carried out during the 2014-2015 Fermilab Test Beam Facility program. The TSW is intended primarily for the purpose of recording expectations for budget estimates and work allocations. The experimenters propose using large-area micro-channel plates assembled without the usual bialkali photocathodes as the active element in sampling calorimeters, Modules without photocathodes can be economically assembled in a glove box and then pumped and sealed using the process to construct photomultipliers, This electromagnetic calorimeter is based on W and Pb absorber plates sandwiched with detectors. Measurements can be made with bare plates and absorber inside the vacuum vessel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 15GSa/s, 1.5GHz bandwidth waveform digitizing ASIC

The PSEC4 custom integrated circuit was designed for the recording of fast waveforms for use in large-area time-of-flight detector systems. The ASIC has been fabricated using the IBM-8RF 0.13 micron CMOS process. On each of 6 analog channels, PSEC4 employs a switched capacitor array (SCA) 256 samples deep, a ramp-compare ADC with 10.5 bits of DC dynamic range, and a serial data readout with the capability of region-of-interest windowing to reduce dead time. The sampling rate can be adjusted between 4 and 15 Gigasamples/second [GSa/s] on all channels and is servo-controlled on-chip with a low-jitter delay-locked loop (DLL). The input signals are passively coupled on-chip with a -3 dB analog bandwidth of 1.5 GHz. The power consumption in quiescent sampling mode is less than 50 mW/chip; at a sustained trigger and readout rate of 50 kHz the chip draws 100 mW. After fixed-pattern pedestal subtraction, the uncorrected integral non-linearity is 0.15% over an 750 mV dynamic range. With a linearity correction, a full 1 V signal voltage range is available.The sampling timebase has a fixed-pattern non-linearity with an RMS of 13%, which can be corrected for precision waveform feature extraction and timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Considerations about Large Area___Low Cost Fast Imaging Photo-detectors

The Large Area Picosecond Photodetectors described in this contribution incorporate a photocathode and a borosilicate glass capillary Micro-Channel Plate (MCP) pair functionalised by atomic layer deposition (ALD) of separate resistive and secondary emission materials. Initial testing with matched pairs of small glass capillary test disks has demonstrated gains of the order of 10{sup 5}-10{sup 6}. Compared to other fast imaging devices, these photodetectors are expected to provide timing resolutions in the 10-100 ps range, and two-dimension position in the sub-millimeter range. If daisy chained, large detectors read at both ends with fast digitising integrated electronics providing zero-suppressed calibrated data should be produced at relatively low cost in large quantities.

47 OTHER INSTRUMENTATION↗

A multi-threshold sampling method for TOF PET signal processing

As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multithreshold sampling method to generate samples of a PET event waveform with respect to a few user-defined amplitudes. In this sampling scheme, one can extract both the energy and timing information for an event. In this paper, we report our prototype implementation of this sampling method and the performance results obtained with this prototype. The prototype consists of two multi-threshold discriminator boards and a time-to-digital converter (TDC) board. Each of the multi-threshold discriminator boards takes one input and provides up to 8 threshold levels, which can be defined by users, for sampling the input signal. The TDC board employs the CERN HPTDC chip that determines the digitized times of the leading and falling edges of the discriminator output pulses. We connect our prototype electronics to the outputs of two Hamamatsu R9800 photomultiplier tubes (PMTs) that are individually coupled to a 6.25 x 6.25 x 25mm{sup 3} LSO crystal. By analyzing waveform samples generated by using four thresholds, we obtain a coincidence timing resolution of about 340 ps and an {approx}18% energy resolution at 511 keV. We are also able to estimate the decay-time constant from the resulting samples and obtain a mean value of 44 ns with an {approx}9 ns FWHM. In comparison, using digitized waveforms obtained at a 20 GSps sampling rate for the same LSO/PMT modules we obtain {approx}300 ps coincidence timing resolution, {approx}14% energy resolution at 511 keV, and {approx}5 ns FWHM for the estimated decay-time constant. Details of the results on the timing and energy resolutions by using the multi-threshold method indicate that it is a promising approach for implementing digital PET data acquisition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗