Engineering PapersβŒ• Search

Engineering topics

Friedman, M.

Publications and source records attributed to Friedman, M..

Design of the ECCE detector for the Electron Ion Collider

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.

47 OTHER INSTRUMENTATION↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of longitudinal double-spin asymmetry measurements in semi-inclusive deep-inelastic scattering from the proton for the ECCE detector design

The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is presented, for the combinations of lepton and hadron beam energies of 5 Γ— 41 GeV 2 and 18 Γ— 275 GeV 2 . The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. Furthermore, the performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<Ξ·<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Search for e β†’ Ο„ charged lepton flavor violation at the EIC with the ECCE detector

The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ ΞΌ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e β†’ Ο„ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the Ο„-leptons created in the DIS process ep β†’ Ο„X are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong Ο„-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e β†’ Ο„ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in Ο„ identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Detector requirements and simulation results for the EIC exclusive, diffractive and tagging physics program using the ECCE detector concept

This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC’s exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark–gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detector system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirm the proposed technology and design satisfy the requirements. Further, the projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb -1 of integrated luminosity. Additionally, insights related to a potential second EIC detector are documented, which could serve as a guidepost for future development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND β†—

Radiative Energy Budget Studies Using Observations from the Earth Radiation Budget Experiment (ERBE)

Our research activities under this NASA grant have focused on two broad topics associated with the Earth Radiation Budget Experiment (ERBE): (1) the role of clouds and the surface in modifying the radiative balance; and (2) the spatial and temporal variability of the earth's radiation budget. Each of these broad topics is discussed separately in the text that follows. The major points of the thesis are summarized in section 3 of this report. Other dissertation focuses on deriving the radiation budget over the TOGA COARE region.

Ackerman, Steven A.β†—

Measurement scanning schemes for terrain modeling

A scanning scheme for the laser rangefinder aboard an autonomous Mars Rover is developed. The rover is expected to be able to traverse an incline of slope up to 25% deg positive or negative. The total azimuth angle of the rangefinder is calculated so that the rangefinder can scan a width of 3 m at a distance of 3 m. A combination of two approaches is considered: scanning the field with a data point spacing appropriate for the terrain modeling technique, followed by zoom scanning with reduced spacing aimed at an obstacle location indicated in a previous terrain scan. It is found that the scan time and total number of data points can be reduced by dividing the field into corridors. The scan is divided into two subscans: the initial scan covering the entire field, and a corridor scan. The corridor scan method reduces the core required in the on-board computer. Hardware changes are expected to be small since the parameters of the corridor are fixed and a continuously variable point spacing is not necessary.

Friedman, M.β†—

A process yields large quantities of pure ribosome subunits

Development of process for in-vitro protein synthesis from living cells followed by dissociation of ribosomes into subunits is discussed. Process depends on dialysis or use of chelating agents. Operation of process and advantages over previous methods are outlined.

Friedman, M.β†—