Atomic oxygen studies on polymers

The purpose was to study the effects of atomic oxygen on the erosion of polymer based materials. The development of an atomic oxygen neutral beam facility using a SURFATRON surface wave launcher that can produce beam energies between 2 and 3 eV at flux levels as high as approx. 10 to the 17th power atoms/cm (2)-sec is described. Thin film dielectric materials were studied to determine recession rates and and reaction efficiencies as a function of incident beam energy and fluence. Accelerated testing was also accomplished and the values of reaction efficiency compared to available space flight data. Electron microscope photomicrographs of the samples' surface morphology were compared to flight test specimens.

Morison, W. D.

An atomic oxygen facility for studying polymer materials for spacecraft applications

A nozzle beam facility utilizing microwave discharge on a helium carrier gas seeded with oxygen to produce atomic oxygen fluxes of the order of 10 to the 15th power atoms/cu cm/sec is described. In addition, limited test results obtained from exposing a graphite/epoxy composite and Kapton (H) film are presented in terms of mass loss measurements and changes in surface morphology.

Tennyson, R. C.

Rarefied gas dynamic effects on mass spectrometric studies of upper planetary atmospheres

Results are presented of measurements obtained with an open-source mass spectrometer both in earth orbit and in a laboratory molecular beam facility. The mass spectrometer/ion source combination was developed in the laboratory to be operable in either of two modes by altering ion extraction potential on ground command, i.e., as a stagnation cavity or to respond only to the incoming molecules of the unperturbed atmosphere. Results indicate that the use of this open-source configuration and dual-mode capability, allied with both standard static calibration and dynamic calibration using high-speed molecular beam techniques in the laboratory, allows collection of useful data on aeronomy of the upper atmosphere of planets and comet tails.

French, J. B.

Molecular beam simulation of planetary atmospheric entry - Some recent results.

Progress is reported in the development of molecular beam techniques to simulate entry into planetary atmospheres. Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of a mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of this simulation technique are discussed, and it is demonstrated that even with certain inadequacies much information useful to the ion source design was obtained. Particularly, it is shown that an open-cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen.

French, J. B.

On the determination of thermospheric atomic-oxygen densities with rocket-borne mass spectrometers.

The experimental investigation of the atomic oxygen response of an open-source mass spectrometer conducted in a high-velocity molecular-beam facility is described, and its results are evaluated. These preliminary results illustrate the value of studies of this type and tentatively support the thesis that in rocket flights of open-source mass spectrometers atomic oxygen loss is not a serious problem.

Neir, A. O.

Molecular beam simulation of planetary atmospheric entry: Some recent results

Molecular beam sources for producing fast beams containing CO2 and atomic oxygen are discussed. Results pertinent to the design and calibration of mass spectrometer ion source for measurement of the Martian atmosphere during the free molecule portion of the entry trajectory are also presented. The shortcomings and advantages of the simulation technique are discussed. It is shown that an open cavity configuration retains sensitivity to atomic oxygen, provides reasonable signal enhancement from the stagnation effect, is not highly sensitive to pitch and yaw effects, and presents no unforeseen problems in measuring CO2 or atomic oxygen. The simulation techniques used provide assistance in designing, developing, and (potentially) in testing and calibrating the required flight instrument.

French, J. B.

Omegatron studies of a skimmed beam system.

Continuum source molecular beam facility, examining effect of source-skimmer distance variation on flux and spatial distribution of beam in collimation chamber downstream

MOLECULAR BEAM

Continuum-source molecular beams.

Beam generation emphasizing free jet behavior, skimming process and feasibility of molecular beams from continuum sources

MOLECULAR BEAM