Engineering Papers⌕ Search

Engineering topics

Fraga, Carlos G.

Publications and source records attributed to Fraga, Carlos G..

Hydrolysis of methylphosphonic anhydride solid to methylphosphonic acid probed by Raman and infrared reflectance spectroscopies

Much is still unknown about the mechanisms and rates of environmental degradation of organophosphorous pesticides and agents. In this study we focus on the degradation of one organophosphorous compound, namely solid methyl phosphonic acid anhydride [CH3P(O)OHOP(O)OHCH3, MPAN] and its rate of conversion to methyl phosphonic acid (MPA) via heterogeneous hydrolysis. Pure MPAN was synthesized and loaded in open sample cups placed inside exposure chambers containing saturated salt solutions to control the relative humidity (RH). The reaction was monitored in the sample cup at various times using both infrared hemispherical reflectance (HRF) spectroscopy and Raman spectroscopy. Calibrated HRF and Raman spectra of both pure reagents as well as gravimetrically prepared mixtures were used to quantify the concentrations of MPAN and MPA throughout the reaction. Results show that both HRF and Raman spectroscopies are convenient non-invasive methods for detection of solid chemicals. The MPAN degradation rate displayed a very strong dependence on relative humidity: At room temperature the reaction showed 50% conversion of the MPAN in 761 ± 54 hours at 33% RH, 33 ± 4 hours at 43% RH, 17 ± 2 hours at 54% RH and just 7 ± 1 hours at 75% RH. Although MPAN hydrolysis is a second-order reaction, the 33 and 43% RH data, at early reaction times, could be fit with a zeroth order reaction, indicating water vapor and MPAN concentrations were not initially rate controlling. The 54 and 75% RH experiments showed significant deliquescence and decay data could only be fit assuming multiple reactions, implying chemical and/or physical processes partially controlled the hydrolysis rate, in contrast to a single process at low relative humidity.

methyl phosphonic acid, methyl phosphonic anhydrid↗

Physicochemical Gas–Solid Sorption Properties of Geologic Materials Using Inverse Gas Chromatography

The goal of this study was to determine the physicochemical properties of a variety of geologic materials using inverse gas chromatography (IGC) by varying probe gas selection, temperature, carrier gas flow rate, and humidity. This is accomplished by measuring the level of interaction between the materials of interest and known probe gases. Identifying a material’s physicochemical characteristics can help provide a better understanding of the transport of gaseous compounds in different geologic materials or between different geological layers under various conditions. Our research in this study focused on measuring the enthalpy (heat) of adsorption, Henry’s constant, and diffusion coefficients of a suite of geologic materials, including two soil types (sandy clay-loam and loam), quartz sand, salt, and bentonite clay, with various particle sizes. The reproducibility of IGC measurements for geologic materials, which are inherently heterogeneous, was also assessed in comparison to the reproducibility for more homogeneous synthetic materials. This involved determining the variability of physicochemical measurements obtained from different IGC approaches, instruments, and researchers. For the investigated IGC-determined parameters, the need for standardization became apparent, including the need for application-relevant reference materials. The inherent physical and chemical heterogeneities of soil and many geologic materials can make the prediction of sorption properties difficult. Characterizing the properties of individual organic and inorganic components can help elucidate the primary factors influencing sorption interactions in more complex mixtures. This research examined the capabilities and potential challenges of characterizing the gas sorption properties of geologic materials using IGC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Challenges to detection: Humidity as a spur to chemical agent change

Detecting chemical agents in outdoor environments such as a battlefield is made challenging by not only the spurious signatures from background chemicals and surfaces (e.g. asphalt, dirt, concrete), but also by the chemical transformation of the actual agents. The change of CW agents to other species can be catalyzed by other chemicals present in the scene, by different substrates, as well as by local weather conditions. Some of the final environmental transformation products are known (e.g. for the G agents methylphosphonic acid), but many of the intermediate chemical states are not, nor are the rates of transformation to the other intermediates or the end products. In this study we have made preliminary optical investigations into the degradation products of a G-agent intermediate, namely methylphosphonic anhydride and its rate of conversion to the more stable methylphosphonic acid. Using infrared and Raman spectroscopies, we have found that the relative humidity (RH) greatly affects the rate of change and we report first results from these studies.

: chemical warfare agent detection, Methylphosphon↗

Solvent Exchange

This report summarizes the work of evaluating the chemical stability of phosphoramidic acid, N-N-diethyl-, bis(2-ethylhexyl) ester under the Solvent Exchange LDRD project, as a potential solvent exchange chemistry and analog to solvent exchange chemistries used in the TALSPEAK and ALSEP processes as alternatives to the use of tri-butyl phosphate in the PUREX process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sorption and Desorption Study of a Nerve-Agent Simulant from Office Materials for Forensic Applications

Dimethyl methylphosphonate (DMMP) was used as a simulant to investigate the sorption and desorption of G-series nerve agents such as sarin (GB) released into an office space. DMMP was disseminated systematically as an aerosol and vapor on three common office materials, cardboard, polyurethane foam, and cured acrylic-based paint. The amount of DMMP initially captured on the office materials and the amount retained over a period of 10 hours was tracked gravimetrically and by solvent extraction and gas chromatography/mass spectrometry (GC/MS). Physicochemical properties of the office media including the specific surface area per mass, polarity, and Henry’s constants were determined to help explain the capture and release of DMMP that was observed. Polyurethane foam was found to have the largest sorption capacity for DMMP in a low-humidity setting, however, cardboard was found to have the largest sorption capacity at higher humidity. A fraction of the DMMP collected desorbed with first-order kinetics from all of the office materials in an open-air atmosphere over 8 hours. However, importantly for forensic purposes relevant to an indoor attack, a significant quantity (most notably on cardboard) of the nerve agent simulant was retained after 6 weeks and could be analyzed efficiently using solvent extraction followed by GC/MS.

chemical forensics↗