Engineering PapersSearch

Engineering topics

Fradet, Mathieu

Publications and source records attributed to Fradet, Mathieu.

Miniaturized Laser Absorption Spectrometer for Combustion Calorimetry and Process Monitoring

A miniaturized tunable laser absorption spectrometer capable of measuring gas-phase concentrations of CO, CO2, and O2 has been developed for operation in spacecraft environments. As part of the Spacecraft Fire Safety Demonstration (Saffire) project, we previously demonstrated the Combustion Product Monitor (CPM) instrument to characterize pyrolysis of relevant test materials in low gravity aboard a transfer vehicle returning from low Earth orbit. Here, we adapted the CPM instrument design to achieve detection of CO, CO2, and O2 with improved minimum detection limits and dynamic range as well as reduced instrument size and power. The instrument can be operated in either an open or sealed configureation, allowing for ambient gas composition measuremnts or in-line monitoring of gas streams. By accurately monitoring CO, CO2, and O2 with broad pressure/temperature calibration and response time on the order of 1 s, the instrument can be used to characterize the dynamics of combustion reactions in a variety of environments.

Briggs, Ryan M.

The Combustion Product Monitor instrument for the spacecraft fire safety demonstration project

The Combustion Product Monitor (CPM) instrument is a six-channel tunable laser absorption spectrometer capable of measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of combustion events and can also facilitate safe post-fire cleanup. Here, we will describe the development of a CPM instrument optimized for operation as part of the Spacecraft Fire Safety Demonstration (Saffire) Project. As part of Saffire, the CPM instrument will measure concentrations of the target gases during low-gravity, reduced pressure oxidative pyrolysis of relevant test materials aboard a transfer vehicle returning from low Earth orbit. We will describe the CPM instrument design, absorption line selection,theoretical and experimental detection limits, and environmental testing.

Briggs, Ryan M.

Passively mode-locked interband cascade lasers

Optical frequency combs have revolutionized the field of high resolution real-time molecular spectroscopy. Here, we demonstrate an electrically-driven optical frequency comb whose sub-picosecond pulses span more than 1 THz of spectral bandwidth centered near 3.3 mm. This is achieved by passively mode locking an interband cascade laser in a multi-contact architecture with gain and saturable absorber sections monolithically integrated on the same chip.

Wysocki, Gerard

2.0 um Wavelength Injection Seed Semiconductor Laser for Lidar Transmitter for Global-Scale Measurements of CO2

Many of the high accuracy Earth science survey missions are planned to use laser-based remote sensing instruments. The 2-μm laser wavelength is of particular interest due to the presence of many CO2 and H20 absorption lines in its vicinity1. Transmitter architectures are typically composed of an optically pumped, frequency-stable, solid-state seed laser and a high-power optical amplifier.2, 3 Taking advantage of the reliability and relative simplicity of semiconductor lasers, this architecture can substantially improve by replacing the solid-state light source with semiconductor lasers of comparable performance. This approach will greatly improve the system reliability, and will simplify instrument integration and space qualification. There are currently very limited semiconductor lasers operating in the 2-m range with performance satisfactory enough for use as an injection seed in a laser absorption spectrometer. Optimally, seed lasers producing greater than 50 mW of continuous-wave (CW), with frequency jitter of less than 1 MHz are desired to reliably resolve the CO2 absorption lines near 2-µm. In this paper, we report the demonstration of high-power, single-longitudinal-mode laterally coupled distributed feedback (LC-DFB) lasers at 2.05 µm wavelength. We measured more than 80 mW of CW power at -10 ºC for devices with a 4-µm-wide ridge and 2-mm-long cavity.

Fradet, Mathieu

Interband Cascade (IC) Optical Frequency Combs

We demonstrate an electrically-driven frequency comb whose sub-picosecond pulses span more than 1 THz of spectral bandwidth centered near 3.6 µm. This is achieved by passively mode locking an interband cascade laser with gain and saturable absorber sections monolithically integrated on the same chip.

Meyer, Jerry R.

Compact Multi-Channel Infrared Laser Absorption Spectrometer for Spacecraft Fire Safety Monitoring

We report on the design of a six-channel tunable laser absorption spectroscopy instrument for measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of fire events while also indicating what materials have been exposed to heating. Continued post-fire monitoring of these hazardous gases can also facilitate safe and effective cleanup. The sensor is a miniaturized version of a five-channel prototype that was previously validated in ground-based oxidative pyrolysis tests. Here, we describe absorption line selection and theoretical detection limits for a sensor with reduced absorption pathlengths for each detection channel, which allows for a substantial reduction in overall instrument footprint. Ultimately, the new instrument is designed to be used in fire safety tests conducted by NASA, where various materials will undergo oxidative pyrolysis in an unmanned spacecraft returning from low Earth orbit.

Briggs, Ryan M.

Monolithic High Power Semiconductor Seed Lasers near 2.05 µm

We report on the development and demonstration of a compact 2-micron semiconductor seed laser for CO2 lidar instruments. Our monolithic high-power fiber-pigtailed semiconductor seed laser will greatly enhance the operability and applicability of IPDA (Integrated Path Differential Absorption) lidar systems for high spatial and temporal resolution CO2 airborne measurements as well as future Earth-orbiting CO2 measurement missions. The compact semiconductor transmitter has a suitably narrow linewidth (less than 100 kilohertz) and enables flexible tuning (greater than 150 gigahertz) over several CO2 absorption lines in the 2.05-micron band.The frequency agility and multi-format modulation capability of the proposed technology, its small size and compatibility with standard DFB (Distributed FeedBack) lasers at the telecom band paves the way for adoption of the attractive 2.05-micron band for CO2 profiling and measurements.

Semiconductor Laser

First Demonstration of Single-Mode Distributed Feedback Type-I GaSb Cascade Diode Laser Emitting near 2.9 µm

We demonstrate GaSb-based laterally-coupled distributed-feedback type-I cascade diode lasers emitting near 2.9 µm as potential sources for OH measurements. The laser heterostructures consist of two GaInAsSb quantum well stages in series separated by GaSb/AlSb/InAs tunnel junction and InAs/AlSb electron injectors. Single-mode emission is generated using second order lateral Bragg grating etched alongside narrow ridge waveguides. The lasers were fabricated into 2-mm-long devices, solder-mounted epi-up on copper submounts, and operate at room temperature. With an anti-reflection coating at the emission facet, the lasers exhibit a typical current threshold of 110 mA at 20 °C and emit more than 14 mW of output power. The Bragg wavelength temperature tuning rate was 0.29 nm/°C.

type-I

Regrowth-Free Mid-Infrared Distributed Feedback Quantum Cascade Lasers with Sub-Watt Power Consumption

We report on room-temperature, continuous-wave operation of single-mode quantum cascade lasers designed for minimal threshold power consumption in the 4 to 10 µm spectral range. Narrow-ridge distributed feedback lasers were developed with plasma-etched sidewall corrugations and infrared-transparent dielectric cladding, enabling fabrication without any epitaxial steps beyond the initial growth of the planar laser wafer. The devices exhibit single-mode emission with stable, mode-hop-free tuning and side-mode suppression greater than 25 dB. We demonstrate packaged single-mode devices with continuous-wave threshold power consumption near 1 W above room temperature.

infrared absorption spectroscopy