Engineering Papers⌕ Search

Engineering topics

Fournier, Sean Donovan

Publications and source records attributed to Fournier, Sean Donovan.

At least 19 records

FRMAC Laboratory Analysis Manual Volume 1, Revision 0

This manual is written for personnel who respond to a nuclear/radiological incident and will be called upon to provide support to ensure that samples receive appropriate laboratory analyses. Overall, this manual provides general guidance and some specific diagrams and forms. However, it is understood that site- and incident-specific operational decisions and procedures may need to be modified at the time of the incident. This manual is intended to provide guidance for laboratory analysis personnel without limiting FRMAC’s ability to integrate the work with other partners and stakeholders. Some of the titles of management positions with the FRMAC have been changed in order to comply with the structure of the Incident Command System (ICS) under the National Incident Management System (NIMS).

61 RADIATION PROTECTION AND DOSIMETRY↗

Mapping and imaging ionizing radiation in two and three dimensions

A two-dimensional imaging system and a two-dimensional or three-dimensional optical tomographic mapping system, each employing gas scintillation induced by ionizing radiation, i.e., radioluminescence, and corresponding methods, are disclosed. The systems may employ one or more cameras and corresponding UV filters (potentially solar blind filters) for imaging a radioluminescent scene. For two-dimensional or three-dimensional mapping, the resultant UV images are spatially registered with one another and then reconstructed to form a three-dimensional tomographic map of the ionizing radiation. The two-dimensional map is a plane of the three-dimensional map. The UV images may be spatially registered by using a reference source, optionally, a calibrated reference source allowing dosimetry calculations for the ionizing radiation. Molecular nitrogen is the primary candidate for the radioluminescent gas, though a controlled ambient in a chamber of nitric oxide, argon, krypton, or xenon may be employed. The reconstruction process employs an algebraic reconstruction technique or an Abel inversion.

Bentz, Brian Z.↗

Consequence Management Cobalt Magnet 2022 Laboratory Analysis: After Action Report

On May 16-20, 2022, federal mission partners (e.g., DOE Consequence Management, CDC, FDA, FBI, DHS) as well as integrated state, local, tribal, and territorial governments took part in Cobalt Magnet 22 (CM22), a large-scale, week-long radiological incident exercise in Austin, Texas, that linked several important national assets (National Search Program, Radiological Assistance Program, and Consequence Management [CM] personnel) into a single response effort. The exercise had nine (9) overarching Objectives and an additional 162 associated Critical Tasks for all the participating organizations. In total, 13 National Core Capabilities spanning 5 Mission Areas were represented in the final exercise. This exercise enabled a full range of capabilities to be fielded together and examine the operational connection between major assets, discover any resource shortages associated with conducting multiple mission areas simultaneously or in close succession, and identify any challenges related to leadership. This report summarizes nearly 100 successes and observations provided from players and controllers supporting the LA Division, Fly Away Laboratory (FAL) and Gamma Spectroscopist operations. The observations were categorized to align with the FRMAC programmatic functional areas to consider for future improvements: Logistics, CBRN Responder, Laboratory Analysis, Sampling and Monitoring, Health and Safety, Gamma Spectroscopist Operations, Fly Away Laboratory, and the FRMAC Interdivision Interoperability Group (FIIG).

54 ENVIRONMENTAL SCIENCES↗

Analytical Action Level Calculator in Turbo FRMAC (FY2020 Close-Out) [Slides]

Objectives: Automate the labor-intensive process of generating Analytical Action Levels (AALs) in Turbo FRMAC to shorten the timeline for planning sampling campaigns and sample analysis during a response. Make the tool output results in a format that is easily imported to RadResponder as a Mixture for use in Analysis Request Forms. Deliver training to EPA on using this new tool in Turbo FRMAC (Delayed due to COVID.

42 ENGINEERING↗

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

RadResponder Nationwide Drill 2020: FRMAC participation After Action Report

On February 11th, 2020 FRMAC participated in the 2020 RadResponder nationwide drill involving survey data review and approval. During this drill, dozens of organizations from across the country participated in uploading simulated survey results to their own RadResponder event and reviewing those data given some "best-practice" guidelines. FRMAC participated in this drill to learn how this process is carried out in RadResponder and to determine some areas of improvement that will make FRMACs use of RadResponder more effective and efficient. As drill participants, the four FRMAC staff each set up their own RadResponder events so they could work independently to work through each step. Each were given an import file with 60 survey measurements to import and review. At the end of the drill a hotwash was held where users were able to ask questions and receive feedback from Chainbridge and FRMAC participants. In summary, several areas for improvement have been identified and will be categorized as items that need immediate attention (Bugs), areas for improvement in the near-term (change requests), and ideas on how the overall process can be improved (feature requests). The items presented in this report by no means reflect all the required changes FRMAC Monitoring and Sampling and Assessment will need to carry out their procedures in RadResponder but do represent a step in the right direction. A full review and exercise of the FRMAC process will need to be conducted with more subject matter experts to discover all the required features FRMAC needs to carry out their mission.

97 MATHEMATICS AND COMPUTING↗

Software Requirements for a Consequence Management Sample Data Simulator for Training and Drills

This document describes the requirements for a software tool that will enable FRMAC to simulate large sets of sample result data that is based realistically on simulated radionuclide deposition grids from NARAC. The user of this tool would be scientists involved in exercise and drill planning or part of the simulation cell of an exercise controller team. A key requirement is that this tool must be able to be run with a reasonable amount of training and job aids by any person within the Assessment, Laboratory Analysis, or Monitoring and Sampling divisions of the FRMAC to support any level of exercise from the small IPX to the national level full scale exercise. This tool should be relatively lean and stand-alone so that the user can run it in the field with limited IT resources. This document will describe the desired architecture, design characteristics, order of operations, and algorithms that can be given to a software development team to assist them in project scoping, costing, and eventually, development.

61 RADIATION PROTECTION AND DOSIMETRY↗

FRMAC Laboratory Analysis Rad Responder Enhancements Requirements

This document will describe the requirements for improvements to the Rad Responder platform to meet the needs of FRMAC Lab Analysis and other users of the sample control and lab analysis modules. The report is broken down into specific sections and organized by the specific deliverables under the FY19 FEMA-NIRT project. This report describes requirements that go beyond what was originally funded under the FY19 FEMA-NIRT project since auxiliary funding is being used on top of FEMA-NIRT funding through the DOE eFRMAC working group. This document describes all the lab analysis requirements for FRMAC Lab Analysis operations. Under each section the reader will find specific user "stories" or use-cases along with specific and technical requirements for each feature. Mock ups and data models will be provided as needed.

97 MATHEMATICS AND COMPUTING↗

Uncertainty Analysis of Consequence Management (CM) Data Products: Extended Analyses.

The goal of this project, started in FY17, is to develop and execute methods of characterizing uncertainty in data products that are developed and distributed by the DOE Consequence Management (CM) Program. This report presents the results of uncertainty analyses performed in FY18 for additional scenarios of increased complexity, including different time phases and radionuclide source terms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

FRMAC Laboratory Analysis RadResponder Gap Analysis and Web Portal Enhancements

The Federal Radiological Monitoring and Assessment Center (FRMAC) relies on accurate and defensible analytical laboratory data to support its mission. FRMAC Laboratory Analysis personnel are responsible for (1) receiving samples, (2) managing samples, and (3) providing data quality assurance. Currently, the RadResponder software application does not meet all these needs. With some modifications, RadResponder could meet the needs for sample receiving functions, but it does not meet the needs of sample management and data quality assurance functions. The FRMAC Laboratory Analysis team has discussed and reviewed the following options moving forward: Option 1: Make minor revisions to RadResponder to improve sample receiving capability, purchase and configure a commercial laboratory information management system (LIMS) to perform sample management and data quality assurance, and build an interface between RadResponder and the commercial-off-the-shelf LIMS. Option 2: Make major revisions to RadResponder for all FRMAC Laboratory Analysis functions to support required sample management and data quality assurance activities. Option 3: Create a custom-built LIMS system to interface with RadResponder. Note: All three options will require the development of a Laboratory Analysis web portal and will require funding for ongoing maintenance and training. The FRMAC Laboratory Analysis team highly recommends Option 1 as the best and most efficient path forward. Commercial-off-the-shelf LIMS products have been proven successful in the laboratory community for decades. Option 1 leverages these proven technologies and takes advantage of RadResponder's current strengths.

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing Minimum Detectable Activity of Whole-Body Counting System in the Presence of Interfering Factors

The recently updated technical standard for the Department of Energy Laboratory Accreditation Program (DOELAP) may soon require accredited laboratories to empirically verify the estimated minimum detectable activity (MDA) for the nuclides of interest measured by in-vivo detection systems. The Radiation Protection Sample Diagnostics (RPSD) program is the SNL on-site DOELAP accredited laboratory that provides in-vivo measurements of ingested gamma-emitting nuclides (or to prove the lack of significant ingested gamma-emitting nuclides) for the internal dosimetry program administered by Radiation Protection Dosimetry Program (RPDP). Currently, the main nuclides of concern for RPDP include cesium-137 and cobalt-60 as specified in the Statement of Work between the two programs. Historically, MDAs for the RPSD whole-body counting system (WBC) were calculated annually as a-priori values by averaging the critical levels (LC) of any twelve subjects with undetected Co-60 and Cs-137 and assuming MDA is twice the decision level. The purpose of this technical basis document is to evaluate the method and process that validates the a-priori MDA of the RPSD WBC.

61 RADIATION PROTECTION AND DOSIMETRY↗