Engineering Papers⌕ Search

Engineering topics

Forien, Jean-Baptiste

Publications and source records attributed to Forien, Jean-Baptiste.

26 records · Page 2

Carbon aerogels with integrated engineered macroporous architectures for improved mass transport

Carbon aerogels (CAs) combine unique properties including ultra-high surface area, high electrical conductivity, corrosion resistance, and robust mechanical properties making them ideal materials for electrochemical applications. Traditional CA synthesis results in isotropic, random nanoporous networks that work well for applications relying on diffusional mass transport. However, many applications would benefit from integration of engineered macroporous network structures that enable directed pressure-gradient-driven mass transport. In this study, we report on using 3D-printed sacrificial polymeric templates to generate templated CAs (t-CAs) with integrated engineered nonrandom macroporous network structures. Specifically, we used projection micro-stereo-lithography (PμSL) and two-photon polymerization direct laser writing (2PP-DLW) to fabricate millimeter-to-centimeter-sized 3D sacrificial polymeric templates with features ranging from tens of microns (PμSL) to 100s of nanometers (2PP-DLW). T-CAs were fabricated by infiltrating the templates with resorcinol-formaldehyde (RF) precursor solution, followed by carbonization at 1050 °C to simultaneously convert the RF gel to a CA and decompose the 3D-printed template, leaving an embedded templated macroporous network structure behind. X-ray computer tomography confirms integration of the macroporous architecture defined by the template. The templated macroporous architecture improves mass transport in t-CAs compared to traditional bulk CA as demonstrated by more uniform activation and their response in electrochemical cyclic voltammetry and galvanostatic charge-discharge tests.

36 MATERIALS SCIENCE↗

X-ray diffraction and in situ pressurization of dentine apatite reveals nanocrystal modulus stiffening upon carbonate removal

Bone-like materials comprise carbonated-hydroxyapatite nanocrystals (c-Ap) embedding a fibrillar collagen matrix. The mineral particles stiffen the nanocomposite by tight attachment to the protein fibrils creating a high strength and toughness material. The nanometer dimensions of c-Ap crystals make it very challenging to measure their mechanical properties. Mineral in bony tissues such as dentine contains 2~6 wt.% carbonate with possibly different elastic properties as compared with crystalline hydroxyapatite. Here we determine strain in biogenic apatite nanocrystals by directly measuring atomic deformation in pig dentine before and after removing carbonate. Transmission electron microscopy revealed the platy 3D morphology while atom probe tomography revealed carbon inside the calcium rich domains. High-energy X-ray diffraction in combination with in situ hydrostatic pressurization quantified reversible c-Ap deformations. Additionally, crystal strains differed between annealed and ashed (decarbonated) samples, following 1 or 10 h heating at 250 °C or 550 °C respectively. Measured bulk moduli (K) and a-/c-lattice deformation ratios (η) were used to generate synthetic K syn and ηsyn identifying the most likely elastic constants C 33 and C 13 for c-Ap. These were then used to calculate the nanoparticle elastic moduli. For ashed samples, we find an average E 11 =107 GPa and E 33 =128 GPa corresponding to ~5% and ~17% stiffening of the a-/c-axes of the nanocrystals as compared with the biogenic nanocrystals in annealed samples. Ashed samples exhibit ~10% lower Poisson's ratios as compared with the 0.25~0.36 range of carbonated apatite. Carbonate in c-Ap may therefore serve for tuning local deformability within bony tissues.

36 MATERIALS SCIENCE↗

Holotomography Phase-Retrieval

Holotomography is a non-destructive x-ray imaging technique which allows to visualize the interior morphology of object without damaging them. It is similar to x-ray computed tomography (CT), but unlike conventional CT, which is based on the attenuation of x-rays passing through the object, holotomography exploits the phase shift caused by the sample. This phase-contrast imaging allows to increase image contrast by recovering refractive index of materials and is proven to be more sensitive to density variations than conventional absorption-based X-ray imaging when applied to low-Z materials. In holotomography, the phase is retrieved by measuring the variations in intensity of the object at different sample to detector distances. Several algorithms exist to perform this task such as, contrast transfer function (CTF), transport of intensity equation (TIE), and a mixed approach which combine both TIE and CTF.

Forien, Jean-Baptiste↗

Effect of laser power on roughness and porosity in laser powder bed fusion of stainless steel 316L alloys measured by X-ray tomography

The quality of metal objects fabricated via laser powder bed fusion are highly affected by process parameters, and their influence on final products is yet to be fully explored. In this work, pyrometry signals of the melt pool were collected from a set of stainless-steel samples during manufacturing and the effect of laser power on porosity and roughness of final printed parts was analyzed. Results show that the melt pool pyrometry signal of contours increases with higher laser power, whereas it is lower and decreases for the infilled part. Post-built X-ray computed tomography imaging reveals that porosity decreases while sample roughness increases upon increasing laser power. The decrease in porosity with increasing laser power is attributed to the larger size of the contour welds that were printed first, leading to an increase in dimension of the final products.

36 MATERIALS SCIENCE↗

Radiopaque Resists for Two-Photon Lithography To Enable Submicron 3D Imaging of Polymer Parts via X-ray Computed Tomography

Two-photon lithography (TPL) is a high-resolution additive manufacturing (AM) technique capable of producing arbitrarily complex three-dimensional (3D) microstructures with features 2–3 orders of magnitude finer than human hair. This process finds numerous applications as a direct route toward the fabrication of novel optical and mechanical metamaterials, miniaturized optics, microfluidics, biological scaffolds, and various other intricate 3D parts. As TPL matures, metrology and inspection become a crucial step in the manufacturing process to ensure that the geometric form of the end product meets design specifications. X-ray-based computed tomography (CT) is a nondestructive technique that can provide this inspection capability for the evaluation of complex internal 3D structure. However, polymeric photoresists commonly used for TPL, as well as other forms of stereolithography, poorly attenuate X-rays due to the low atomic number (Z) of their constituent elements and therefore appear relatively transparent during imaging. We present the development of optically clear yet radiopaque photoresists for enhanced contrast under X-ray CT. We have synthesized iodinated acrylate monomers to formulate high-Z photoresist materials that are capable of forming 3D microstructures with sub-150 nm features. In addition, we have developed a formulation protocol to match the refractive index of the photoresists to the immersion medium of the objective lens so as to enable dip-in laser lithography, a direct laser writing technique for producing millimeter-tall structures. Our radiopaque photopolymer then resists increase X-ray attenuation by a factor of more than 10 times without sacrificing the sub-150 nm feature resolution or the millimeter-scale part height. Thus, our resists can successfully replace existing photopolymers to generate AM parts that are suitable for inspection via X-ray CT. By providing the “feedstock” for radiopaque AM parts, our resist formulation is expected to play a critical role in enabling fabrication of functional polymer parts to tight design tolerances.

36 MATERIALS SCIENCE↗