Engineering PapersSearch

Engineering topics

Flower, D. A.

Publications and source records attributed to Flower, D. A..

At least 19 records

Validation of UARS Microwave Limb Sounder Ozone Measurements

This paper describes the validation of ozone data from the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS). The MLS ozone retrievals are obtained from the calibrated microwave radiances (emission spectra) in two separate bands, at frequencies near 205 and 183 GHz. Analyses described here focus on the MLS Version 3 data (the first set of files made publicly available). We describe results of simulations performed to assess the quality of the retrieval algorithms, in terms of both mixing ratio and radiance closure. From actual MLS observations, the 205-GHz ozone retrievals give better closure (smaller radiance residuals) than that from the 183-GHz measurements and should be considered more accurate from the calibration aspects. However, the 183-GHz data are less noise limited in the mesosphere and can provide the most useful scientific results in that region. We compare the retrieved 205-GHz ozone profiles in the middle-to lower stratosphere to ozonesonde measurements at a wide range of latitudes and seasons. Ground-based lidar data from Table Mountain, California, provide a good reference for comparisons at higher altitudes. Based on these analyses, comparisons with balloon-borne measurements and others, as well as a detailed budget of estimated uncertainties, MLS results appear to be generally of high quality, with some biases worth mentioning. Results for the lowermost stratosphere (approx. 50 to 100 bPa) are still in need of improvement. A set of estimated precision and accuracy values is derived for the MLS ozone data sets. We also comment on recent updates in the retrieval algorithms and their impact on ozone values.

Froidevaux, L.

Validation of UARS Microwave Limb Sounder ClO Measurements

Validation of stratospheric ClO measurements by the Microwave Limb Sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is described. Credibility of the measurements is established by (1) the consistency of the measured ClO spectral emission line with the retrieved ClO profiles and (2) comparisons of ClO from MLS with that from correlative measurements by balloon-based, ground-based, and aircraft-based instruments. Values of "noise" (random), "scaling" (multiplicative), and "bias" (additive) uncertainties are determined for the Version 3 data, in the first version public release of the known artifacts in these data are identified. Comparisons with correlative measurements indicate agreement to within the combined uncertainties expected for MLS and the other measurements being compared. It is concluded that MLS Version 3 ClO data, with proper consideration of the uncertainties and "quality" parameters produced with these data, can be used for scientific analyses at retrieval surfaces between 46 and 1 hPa (approximately 20-50 km in height). Future work is planned to correct known problems in the data and improve their quality.

Waters, J. W.

Calibration of the Microwave Limb Sounder on the Upper Atmosphere Research Satellite

The Microwave Limb Sounder (MLS) is a three-radiometer, passive, limb emission instrument onboard the Upper Atmosphere Research Satellite (UARS). Radiometric, spectral and field-of-view calibrations of the MLS instrument are described in this paper. In-orbit noise performance, gain stability, spectral baseline and dynamic range are described, as well as use of in-flight data for validation and refinement of prelaunch calibrations. Estimated systematic scaling uncertainties (3 sigma) on calibrated limb radiances from prelaunch calibrations are 2.6% in bands 1 through 3, 3.4% in band 4, and 6% in band 5. The observed systematic errors in band 6 are about 15%, consistent with prelaunch calibration uncertainties. Random uncertainties on individual limb radiance measurements are very close to the levels predicted from measured radiometer noise temperature, with negligible contribution from noise and drifts on the regular in-flight gain calibration measurements.

Jarnot, R. F.

Arctic Ozone Depletion Observed by UARS MLS During the 1994-95 Winter

During the unusually cold 1994-95 Arctic winter, the Microwave Limb Sounder observed enhanced chlorine monoxide (ClO) in late Dec and throughout Feb and early Mar. Late Dec ClO was higher than during any of the previous 3 years, consistent with the colder early winter. Between late Dec 1994 and early Feb 1995, 465 K (about 50 hPa) vortex-averaged ozone (03) decreased by about 15%, with local decreases of about 30%; additional local decreases of about 5% were seen between early Feb and early Mar. Transport calculations indicate that vortex-averaged chemical loss between late Dec and early Feb was about 20% at 465 K, with about 1/4 of that masked by downward transport of O3. This Arctic chemical O3 loss is not readily detectable in MLS column O3 data.

Manney, G. L.

UARS MLS observations of lower stratospheric ClO in the 1992-93 and 1993-94 Arctic winter vortices

Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) measurements of lower stratospheric ClO during 1992-93 and 1993-94 Arctic winters are presented. Enhanced ClO in the 1992-93 winter was first observed in early December, and extensively during February when temperatures were continually low enough for polar stratospheric cloud (PSCs). Sporadic episodes of enhanced ClO were observed for most of the 1993-94 winter as minimum temperatures hovered near the PSC threshold, with largest ClO amounts occurring in early March after a sudden deep cooling in late February.

Waters, J. W.

UARS MLS Observations of Lower Stratospheric ClO in the 1992-93 and 1993-94 Arctic Winter Vortices

UARS (Upper Atmosphere Research Satellite) MLS (Microwave Limb Sounder) measurements of lower stratospheric ClO during the 1992-93 and 1993-94 Arctic winters are presented. Enhanced ClO in the 1992-93 winter was first observed in early December, and extensively during February when temperatures were continually low enough for PSCs. Sporadic episodes of enhanced ClO were observed for most of the 1993-94 winter as minimum temperatures hovered near the PSC threshold, with largest ClO amounts occurring in early March after a sudden deep cooling in late February.

Waters, J. W.

Interhemispheric differences in polar stratospheric HNO3, H2O, ClO, and O3

Simultaneous global measurements of nitric acid (HNO3), water (H2O), chlorine monoxide (ClO), and ozone (O3) in the stratosphere have been obtained over complete annual cycles in both hemispheres by the Microwave Limb Sounder on the Upper Atmosphere Research Satellite. A sizeable decrease in gas-phase HNO3 was evident in the lower stratospheric vortex over Antarctica by early June 1992, followed by a significant reduction in gas-phase H2O after mid-July. By mid-August, near the time of peak ClO, abundances of gas-phase HNO3 and H2O were extremely low. The concentrations of HNO3 and H2O over Antarctica remained depressed into November, well after temperatures in the lower stratosphere had risen above the evaporation threshold for polar stratospheric clouds, implying that denitrification and dehydration had occurred. No large decreases in either gas-phase HNO3 or H2O were observed in the 1992-1993 Arctic winter vortex. Although ClO was enhanced over the Arctic as it was over the Antarctic, Arctic O3 depletion was substantially smaller than that over Antarctica. A major factor currently limiting the formation of an Arctic ozone 'hole' is the lack of denitrification in the northern polar vortex, but future cooling of the lower stratosphere could lead to more intense denitrification and consequently larger losses of Arctic ozone.

Santee, M. L.

Arctic Ozone Depletion Observed by UARS MLS During the 1994-95 Winter

The Earth's northern hemisphere lower stratosphere was unusually cold in December 1995 and January 1995. Temperatures low enough for polar stratospheric cloud formation persisted until mid-March 1995, and the polar vortex was exceptionally strong throughout the winter. Previous and current Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) measurements indicating ozone depletion are given.

arctic

Validation of UARS MLS Ozone Measurements

This paper describes the validation of ozone data from the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS). The MLS ozone retrievals are obtained from the calibrated microwave radiances (emission spectra) in two separate bands, at frequencies near 205 and 183 GHz.

Microwave Limb Sounder (MLS)

Interhemispheric Differences in Dentifrication and Related Processes Affecting Polar Ozone

The severe depletion of stratospheric ozone over Antarctica in late winter and early spring is caused by enhanced CLO abundances arising from heterogeneous reactions on polar stratospheric clouds (PSCs). CLO abundances comparable to those over Antarctica have also been observed throughout the Arctic Vortex, but the accompanying loss of Arctic ozone has been much less severe.

ozone depletion

The Upper Atmosphere Research Satellite microwave limb sounder instrument

The microwave limb sounder (MLS) on the Upper Atmosphere Research Satellite (UARS) is the first satellite experiment using limb sounding techniques at microwave frequencies. Primary measurement objectives are stratospheric ClO, O3, H2O, temperature, and pressure. Measurements are of thermal emission: all are performed simultaneously and continuously and are not degraded by ice clouds or volcanic aerosols. The instrument has a 1.6-m mechanically scanning antenna system and contains heterodyne radiometers in spectral bands centred near 63, 183, and 205 GHz. The radiometers operate at ambient temperature and use Schottky-diode mixers with local oscillators derived from phase-locked Gunn oscillators. Frequency tripling by varactor multipliers generates the 183- and 205-GHz local oscillators, and quasi-optical techniques inject these into the mixers. Six 15-channel filter banks spectrally resolve stratospheric thermal emission lines and produce an output spectrum every 2 s. Thermal stability is sufficient for 'total power' measurements which do not require fast chopping. Radiometric calibration, consisting of measurements of cold space and an internal target, is performed every 65-s limb scan. Instrument in-orbit performance has been excellent, and all objectives are being met.

Barath, F. T.

Stratospheric ClO and ozone from the Microwave Limb Sounder on the Upper Atmosphere Research Satellite

Concentrations of atmospheric ozone and of ClO (the predominant form of reactive chlorine responsible for stratospheric ozone depletion) are reported for both the Arctic and Antarctic winters of the past 18 months. Chlorine in the lower stratosphere was almost completely converted to chemically reactive forms in both the northern and southern polar winter vortices. This occurred in the south long before the development of the Antarctic ozone hole, suggesting that ozone loss can be masked by influx of ozone-rich air.

Waters, J. W.

Microwave Atmospheric-Pressure Sensor

Report describes tests of microwave pressure sounder (MPS) for use in satellite measurements of atmospheric pressure. MPS is multifrequency radar operating between 25 and 80 GHz. Determines signal absorption over vertical path through atmosphere by measuring strength of echoes from ocean surface. MPS operates with cloud cover, and suitable for use on current meteorological satellites.

Flower, D. A.

Experimental validation of a millimeter wave radar technique to remotely sense atmospheric pressure at the Earth's surface

Experiments with a millimeter wave radar operating on the NASA CV-990 aircraft which validate the technique for remotely sensing atmospheric pressure at the Earth's surface are described. Measurements show that the precise millimeter wave observations needed to deduce pressure from space with an accuracy of 1 mb are possible, that sea surface reflection properties agree with theory and that the measured variation of differential absorption with altitude corresponds to that expected from spectroscopic models.

Flower, D. A.