Engineering Papers⌕ Search

Engineering topics

Flood, K.

Publications and source records attributed to Flood, K..

First test results of the trans-impedance amplifier stage of the ultra-fast HPSoC ASIC

Abstract We present the first results from the HPSoC ASIC designed for readout of Ultra-fast Silicon Detectors. The 4-channel ASIC manufactured in 65 nm CMOS by TSMC has been optimized for 50 μm thick AC-LGAD. The evaluation of the analog front end with β-particles impinging on 3 × 3 AC-LGAD arrays (500 μm pitch, 200 × 200 μm 2 metal) confirms a fast output rise time of 600 ps and good timing performance with a jitter of 45 ps. Further calibration experiments and TCT laser studies indicate some gain limitations that are being investigated and are driving the design of the second-generation pre-amplification stages to reach a jitter of 15 ps.

Instruments & Instrumentation↗

Electronics for Fast Timing

Picosecond-level timing will be an important component of the next generation of particle physics detectors. The ability to add a 4$^{th}$ dimension to our measurements will help address the increasing complexity of events at hadron colliders and provide new tools for precise tracking and calorimetry for all experiments. Detectors are described in detail on other whitepapers. In this note, we address challenges in electronics design for the new generations of fast timing detectors

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of branching fractions and asymmetry parameters of $ {\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0} $, $ {\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0} $, and $ {\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -} $ decays at Belle

Using a data sample of 980 fb -1 collected with the Belle detector at the KEKB asymmetric-energy e + e - collider, we study the processes of ${\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}$, ${\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0}$, and ${\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -}$ for the first time. The relative branching ratios to the normalization mode of ${\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}$ are measured to be ${\displaystyle \begin{array}{c}\mathcal{B}\left({\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}\right)/\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)=0.18\pm 0.02\left(\mathrm{stat}.\right)\pm 0.01\left(\mathrm{syst}.\right),\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0}\right)/\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)=0.69\pm 0.03\left(\mathrm{stat}.\right)\pm 0.03\left(\mathrm{syst}.\right),\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -}\right)/\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)=0.34\pm 0.06\left(\mathrm{stat}.\right)\pm 0.02\left(\mathrm{syst}.\right),\end{array}}$ where the uncertainties are statistical and systematic, respectively. We obtain ${\displaystyle \begin{array}{c}\mathcal{B}\left({\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}\right)=\left(3.3\pm 0.3\left(\mathrm{stat}.\right)\pm 0.2\left(\mathrm{syst}.\right)\pm 1.0\left(\mathrm{ref}.\right)\right)\times {10}^{-3},\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^0{\overline{K}}^{\ast 0}\right)=\left(12.4\pm 0.5\left(\mathrm{stat}.\right)\pm 0.5\left(\mathrm{syst}.\right)\pm 3.6\left(\mathrm{ref}.\right)\right)\times {10}^{-3},\\ {}\mathcal{B}\left({\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast 0}\right)=\left(6.1\pm 1.0\left(\mathrm{stat}.\right)\pm 0.4\left(\mathrm{syst}.\right)\pm 1.8\left(\mathrm{ref}.\right)\right)\times {10}^{-3},\end{array}}$ where the uncertainties are statistical, systematic, and from $\mathcal{B}\left({\Xi}_c^0\to {\Xi}^{-}{\pi}^{+}\right)$, respectively. The asymmetry parameters $\alpha \left({\Xi}_c^0\to \Lambda {\overline{K}}^{\ast 0}\right)$ and $\alpha \left({\Xi}_c^0\to {\Sigma}^{+}{K}^{\ast -}\right)$ are 0.15 ± 0.22(stat.) ± 0.04(syst.) and -0.52 ± 0.30(stat.) ± 0.02(syst.), respectively, where the uncertainties are statistical followed by systematic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e Calorimeter Final Technical Design Report

Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, status and test of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab searches for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The dynamics of such a process is well modeled by a two-body decay, resulting in a monoenergetic electron with an energy slightly below the muon rest mass (104.967 MeV). The calorimeter of this experiment plays an important role to provide excellent particle identification capabilities and an online trigger filter while aiding the track reconstruction capabilities. The baseline calorimeter configuration consists of two disks each made with ~700 undoped CsI crystals read out by two large area UV-extended Silicon Photomultipliers. Furthermore, these crystals match the requirements for stability of response, high resolution and radiation hardness. In this paper we present the final calorimeter design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The calorimeter of the Mu2e experiment at Fermilab

Here, the Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10 -4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and status of the Mu2e electromagnetic calorimeter

Here, the Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5×10 –17 after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF 2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D; studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy and time resolution of a LYSO matrix prototype for the Mu2e experiment

We have measured the performances of a LYSO crystal matrix prototype tested with electron and photon beams in the energy range 60–450 MeV. Furthermore, this study has been carried out to determine the achievable energy and time resolutions for the calorimeter of the Mu2e experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗