Non-destructive Post-Transient Examination Results of the MOXTOP-1 Experiment

The MOXTOP-1 experiment has been assembled and irradiated in INL’s HFEF and TREAT facilities followed by disassembly of the experiment to enable initial post-transient examination. Results of neutron radiography of the fuel pin still in the THOR capsule were somewhat inconclusive due to the additional scatter and attenuation from the iron heat sink included in the design. Nonetheless, no obvious failure or fuel relocation could be identified in the radiography. Following disassembly of the fuel pin from the capsule, initial visual inspections were performed, and documented via images obtained through the hot cell window. No obvious signs of fuel failure were identified, indicating that the fuel pin remained intact during the transient. Some discoloration was observed near the middle of the fuel pin, likely corresponding to the fueled zone indicating that that region may have reached a relatively high temperature. Pre-transient, and post-transient profilometry of the fuel pin were performed and compared. Some additional strain displacement in the bottom portion of the fuel zone is identified, but remains well below 1%.

Mixed Oxide

Sensor Qualification for the Development of Advanced Reactors

A temperature sensor qualification device is undergoing development and testing in order to qualify temperature sensors for advanced reactor metrology applications. This device will provide National Institute of Standards and Technology (NIST) traceable performance testing of temperature sensors while under the high radiation environments experienced while in-core. This is completed by utilizing retractable sensors which transfer the measurements from ex-core to in-core sensors. A detailed discussion of the uncertainty propagation associated with this comparative process is provided. Experimental testing of the temperature distribution occurring in the device has begun and is reported on. It is pertinent to minimize this temperature distribution to prevent variation in sensor measurements. This variation will be indistinguishable from sensor drift for in-pile applications and would result in unnecessarily conservative uncertainty bounds.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN

Resumption of SFR Overpower Testing and Post-Transient Examination of the THOR-C-2 Irradiation Test

Transient overpower testing for fuel safety research and development has resumed at Idaho National Laboratory. The THOR-C-2 commissioning test has been performed and post-transient examination has been performed revealing the intended failure near the top of the fuel zone. This paves the way for future testing on previously irradiated fuels that will support fuel development and qualification.

advanced reactors

Conceptual Design of Neutron Sensor Qualification Device

The Advanced Sensors and Instrumentation Program at Idaho National Laboratory has been formulating strategies to qualify sensors for use in nuclear environments, particularly in irradiation experiments and advanced reactors. When qualifying neutron sensors for use in high-temperature environments, the wide range of neutron flux levels and representative energy spectra presents significant challenges. This paper discusses the development of the Neutron Sensor Qualification Device (NQD), which is designed to test neutron sensors in high temperature controlled environments with known neutron spectra, addressing the spatial and spectral complexities of neutron fluxes in reactor cores. The proposed NQD will be situated in the exposure room at the Armed Forces Radiobiology Research Institute, thus affording a unique capability to expose sensors to high neutron and gamma fluxes. To achieve thermal control, the device will utilize a radiation-hardened tube furnace, accommodating multiple sensors and neutron activation dosimetry wires. Titanium, iron, and cobalt dosimeter wires are chosen from the American Society for Testing and Materials and International Reactor Dosimetry and Fusion File libraries as references for providing energy-dependent fluence measurements. The design ensures precise sensor positioning to minimize mutual shielding and flux perturbation, which are evaluated via Monte Carlo N particle Transport Code (MCNP) simulations. These simulations have informed the development of guidelines on sensor placement within the NQD. The NQD is essential to the qualification of neutron sensors for advanced reactor technologies. It enables controlled testing of a statistically significant number of sensors, thereby supporting assessments of sensor performance across various neutron flux levels and temperatures. This paper highlights the detailed planning for the NQD prototype, along with its inaugural irradiation (scheduled for fiscal year [FY] 2025). The results from this initial testing will be fundamental in evaluating the device’s performance and establishing measurement uncertainty for in-pile neutron sensor measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND