Engineering Papers⌕ Search

Engineering topics

Fiske, G. H.

Publications and source records attributed to Fiske, G. H..

Turbofan aft duct suppressor study. Contractor's data report of mode probe signal data

Acoustic modal distributions were measured in a fan test model having an annular exhaust duct for comparison with theoretically predicted acoustic suppression values. This report contains the amplitude and phase data of the acoustic signals sensed by the transducers of the two mode probes employed in the measurement. Each mode probe consisted of an array of 12 transducers sensing the acoustic field at three axial positions and four radial positions.

Fiske, G. H.↗

Turbofan aft duct suppressor study

Suppressions due to acoustic treatment in the annular exhaust duct of a model fan were theoretically predicted and compared with measured suppressions. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Modal distributions of the fan noise source (fan-stator interaction only) were measured using in-duct modal probes. The flow profiles were also measured in the vicinity of the modal probes. The acoustic impedance of the single degree of freedom treatment was measured in the presence of grazing flow. The measured values of mode distribution of the fan noise source, the flow velocity profile and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions, under the assumption of uniform flow in the duct, compared well with the suppressions measured in the duct for all test conditions. The interaction modes generated by the rotor-stator interaction spanned a cut-off ratio range from nearly 1 to 7.

Syed, A. A.↗

Measurement of acoustic modes and wall impedance in a turbofan exhaust duct

Acoustic measurements made with in-duct modal probes show how individual acoustic modes, as generated by fan/stator interaction, interact with a well-characterized liner. This measured attenuation provides a critical test for predicted attenuation as developed from the theoretical analysis of sound propagation in annular ducts with treatment and sheared flow. The primary investigations took place in the exhaust duct of a model fan mounted in an anechoic chamber. The results presented include induct attenuation, sound power attenuation as measured in the far field, and in-situ acoustic impedance measurements of the treated wall sections. Good theory/experiment agreement was found; the differences of treatment suppression between theory and measured values differed at most by 2.7 dB.

Fiske, G. H.↗

Sound propagation in segmented exhaust ducts - Theoretical predictions and comparison with measurements

Suppressions due to acoustic treatment in the annular exhaust duct of a model fan have been theoretically predicted and compared with measurements. The predictions are based on the modal analysis of sound propagation in a straight annular flow duct with segmented treatment. Measured values of the mode distribution of the fan noise source (fan-stator interaction source only) and the acoustic impedance of the treatment in the duct were used as input to the prediction program. The predicted suppressions (under the assumption of uniform flow in the duct) compared well with the measured in-duct suppression for all test conditions. The measurements were made in an anechoic chamber and the interaction modes generated in the fan spanned a cut-off ratio range from nearly one to seven.

Joshi, M. C.↗