Engineering Papers⌕ Search

Engineering topics

Fisher, Peter

Publications and source records attributed to Fisher, Peter.

Task F - Lepton Quark Studies

Final report on a project to commission and operate a dark matter detector, and to develop the DarkLight experiment to search for massive photon-like particles that could be evidence for dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Quasi-Periodic Linear Feeder for the Impurity Granular Injection on DIII-D

Injection of solid nonfuel pellets has been actively used as a tool for pacing and mitigation of edge localized modes (ELMs). In DIII-D, effective ELM pacing has been demonstrated by the high-frequency injection of lithium and carbon submillimeter spheres, using the impurity granule injector (IGI). This device injects granules into the plasma at speeds up to 150 m/s, through impact with a rotating impeller. In the IGI, high-frequency granule delivery was accomplished through a vibrational granule dropper, in which high time-average rates are obtained at the cost of lack of period control. Here, we present a new in-line granule feeder, capable of delivering granules of size 0.2-2 mm with no restriction of material properties, at quasi-periodic rates of up to 150 Hz, for 0.7-mm diameter lithium granules (600 Hz using 0.3-mm granules). The new dropper mechanism combines two piezo-in-line units; one which feeds the impeller and one which circulates granules that are filtered out of the feeder path. A remotely adjustable filter eliminates granules that are stacked, oversized, or side by side allowing the formation of a single moving granule injection line. The granules fall off the in-line feeder exit one at a time, achieving a quasi-periodic delivery rate proportional to the exit speed. At higher rates, the periodicity deteriorates. This behavior was studied using high-speed cameras and electrostatic measurements, and it was found that at drop rates <60 Hz, the granule delivery period has a variation of ±25% which appears to be caused by gaps which develop in the last centimeter of the injection line, as granules exit off the moving track. The linear feeder concept is robust against bridge instabilities and clogging issues, thanks to the simple diverter filter and constant recirculation of granules. Furthermore, the open-top design of the device facilitates refilling the device from separate reservoirs and has easy access for directly monitoring operation and adjustment. This paper describes the details of the in-line feeder design, along with several design iterations. The goal is a robust in-vacuum mechanism that can deliver granule flow ranging from a single particle to a line of particles at 150 per second, using different sizes and materials from the same apparatus.

42 ENGINEERING↗

Measurement of the directional sensitivity of Dark Matter Time Projection Chamber detectors

The dark matter time projection chamber (DMTPC) is a direction-sensitive detector designed to measure the direction of recoiling 19 F and 12 C nuclei in low-pressure CF 4 gas using optical and charge readout systems. In this paper, we employ measurements from two DMTPC detectors, with operating pressures of 30–60 torr, to develop and validate a model of the directional response and performance of such detectors as a function of recoil energy. Using our model as a benchmark, we formulate the necessary specifications for a scalable directional detector with sensitivity comparable to that of current-generation counting (nondirectional) experiments, which measure only recoil energy. Furthermore assuming the performance of existing DMTPC detectors, as well as current limits on the spin-dependent WIMP-nucleus cross section, we find that a 10–20 kg scale direction-sensitive detector is capable of correlating the measured direction of nuclear recoils with the predicted direction of incident dark matter particles and providing decisive (3σ) confirmation that a candidate signal from a nondirectional experiment was indeed induced by elastic scattering of dark matter particles off of target nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direction sensitive neutron detector

A neutron detector includes a pressure vessel, an electrically conductive field cage assembly within the pressure vessel and an imaging subsystem. A pressurized gas mixture of CF 4 , 3 He and 4 He at respective partial pressures is used. The field cage establishes a relatively large drift region of low field strength, in which ionization electrons generated by neutron-He interactions are directed toward a substantially smaller amplification region of substantially higher field strength in which the ionization electrons undergo avalanche multiplication resulting in scintillation of the CF.sub.4 along scintillation tracks. The imaging system generates two-dimensional images of the scintillation patterns and employs track-finding to identify tracks and deduce the rate and direction of incident neutrons. One or more photo-multiplier tubes record the time-profile of the scintillation tracks permitting the determination of the third coordinate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermophotovoltaic energy generation

Inventive systems and methods for the generation of energy using thermophotovoltaic cells are described. Also described are systems and methods for selectively emitting electromagnetic radiation from an emitter for use in thermophotovoltaic energy generation systems. In at least some of the inventive energy generation systems and methods, a voltage applied to the thermophotovoltaic cell (e.g., to enhance the power produced by the cell) can be adjusted to enhance system performance. Certain embodiments of the systems and methods described herein can be used to generate energy relatively efficiently.

14 SOLAR ENERGY↗

DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility

We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.

Balewski, Jan↗

The DarkLight Experiment at the JLab FEL

DarkLight will study the production of gauge bosons associated with Dark Forces theories in the scattering of 100 MeV electrons on proton a target. DarkLight is a spectrometer to measure all the final state particles in e^- +p --> e^- +p + e^- + e^+. QED allows this process and the invariant mass distribution of the e+e- pair is a continuum from nearly zero to nearly the electron beam energy. Dark Forces theories, which allow the dark matter mass scale to be over 1 TeV, predict a gauge boson A' in the mass range of 10-1,000 MeV and decays to an electron-positron pair with an invariant mass of mA'. We aim to search for this process using the 100 MeV, 10 mA electron beam at the JLab Free Electron Laser impinging on a hydrogen target with a 10^19cm^?2 density. The resulting luminosity of 6×10^35/cm^2-s gives the experiment enough sensitivity to probe A' couplings of 10?9a. DarkLight is unique in its design to detect all four particles in the final state. The leptons will be measured in a large high-rate TPC and a silicon sensor will measure the protons. A 0.5 T solenoidal magnetic field provides the momentum resolution and focuses the copious Moeller scattering background down the beam line, away from the detectors. A first beam test has shown the FEL beam is compatible with the target design and that the hall backgrounds are manageable. The experiment has been approved by Jefferson Lab for first running in 2017.

Fisher, Peter↗

Design and Construction of Prototype Dark Matter Detectors: ΔLepton Quark Studies (LQS)

The Lepton Quark Studies (LQS) group is engaged in searching for dark matter using the Dark Matter Time Projection Chamber (DMTPC) at the Waste Isolation Pilot Plant (WIPP) (Carlsbad, NM). DMTPC is a direction-sensitive dark matter detector designed to measure the recoil direction and energy deposited by fluorine nuclei recoiling from the interaction with incident WIMPs. In the past year, the major areas of progress have been: • to publish the first dark matter search results from a surface run of the DMTPC prototype detector, • to build and install the 10L prototype in the underground laboratory at WIPP which will house the 1 m 3 detector, and • to demonstrate charge and PMT readout of the TPC using prototype detectors, which allow triggering and z measurement to be used in the 1 m 3 detector under development.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Maximum patch method for directional dark matter detection

Present and planned dark matter detection experiments search for WIMP-induced nuclear recoils in poorly known background conditions. In this environment, the maximum gap statistical method provides a way of setting more sensitive cross section upper limits by incorporating known signal information. We give a recipe for the numerical calculation of upper limits for planned directional dark matter detection experiments, that will measure both recoil energy and angle, based on the gaps between events in two-dimensional phase space.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗