Engineering Papers⌕ Search

Engineering topics

Fisher, A.

Publications and source records attributed to Fisher, A..

At least 37 records · Page 2

Influence of proton radiation on the minority carrier lifetime in midwave infrared InAs/InAsSb superlattices

Influence of proton radiation on the minority carrier lifetime and on carrier concentrations in InAs/InAsSb superlattices has been studied for radiation doses up to 300 krad. The lifetime decreased from 1.8 μs down to 430 ns as the dose was increased. A variation of the carrier concentration in the range 1–2 × 10{sup 15} with increasing radiation dose was observed. The lifetime drop was however mainly caused by added Shockley-Read-Hall defects in the material. The position of these Shockley-Read-Hall centers was estimated to ∼60 meV below the conduction band edge from comparison between calculated and measured temperature dependencies of the minority carrier lifetime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low Frequency 1/f Noise on QWIPs, nBn, and Superlattice Focal Plane Array

Noise Equivalent Difference Temperature (NE△T) is a standard performance metric for most infrared focal plane array (FPA) systems. The frequency bandwidth and range associated with NE△T is at high frequency and it does not describe the long time noise behavior or the very low frequency noise of the FPA. Very low frequency noise measurement requires data capture that takes longer time duration and sampling interval. This study investigates low frequency noise in QWIP, nBn and LWIR n-type Complementary Barrier Infrared Detector (CBIRD) FPAs. The corner frequencies are extracted from the power spectral density (PSD) as function of frequency. The peak wavelength, quantum efficiency of QWIP detector are 6.2 µm and 2 %, respectively. QWIP FPA has a mean NE△T ~ 25 mK at an operating temperature of 65 K and an integration time of 16 msec. The mean QWIP PSD plot shows a corner frequency of < 0.5 mHz. The nBn FPA with 4 µm cut off and quantum efficiency of 67 % has NE△T ~ 15.6 mK at an integration time ~ 7.52 msec and an operating temperature of 120 K. The nBn has corner frequency of > 50 mHz. Lastly the n-type CBIRD FPA with a 50% cutoff at 8.8 µm and quantum efficiency of ~ 50 % has an NE△T ~ 18.6 mK at an integration time of 1.86 msec and operating temperature 120 K. The superlattice FPA has a corner frequency ~ 10 mHz. The investigation of the tail on the NE△T histogram reveals that its origin is not accounted for entirely by the high noise current, but also it needs the inclusion of lower responsivity for some pixels.

Pepper, B.↗

Beam studies at the SPEAR3 synchrotron using a digital optical mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500 mA circulating in the storage ring (equivalently 392 nC). Each injection pulse contains 40–80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during user operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by imaging the visible component of the synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera, makes it possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, a high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superlattice Infrared Photodetector Research at the Jet Propulsion Laboratory

III-V semiconductors offer a highly effective platform for the development of sophisticated heterostructure-based MWIR and LWIR detectors, as exemplified by the high-performance double heterostructure (DH) nBn, XBn, and type- II superlattice infrared detectors. A key enabling design element is the unipolar barrier, which is used to implement the complementary barrier infra-red detector (CBIRD) design for increasing the collection efficiency of photo-generated carriers, and reducing dark current generation without impeding photocurrent flow. Heterostructure superlattice detectors that make effective use of unipolar barriers have demonstrated strong reduction of generation-recombination (G-R) dark current due to Shockley-Read-Hall (SRH) processes. In the last several years we solely focused on the development of antimonide based IR detectors. Recently, we demonstrated RoA values over 14,000 Ohm sq cm for a 9.9 micron cutoff device by incorporating electron-blocking and hole-blocking unipolar barriers. This device has shown 300K BLIP operation with f/2 optics at 87 K with blackbody D* of 1.1x10(exp 11) cm Hz1/2/W.

focal planes↗

A tunable, linac based, intense, broad-band THz source forpump-probe experiments

We propose an intense THz source with tunable frequency and bandwidth that can directly interact with the degrees of freedom that determine the properties of materials and thus provides a new tool for controlling and directing these ultrafast processes as well as aiding synthesis of new materials with new functional properties. This THz source will broadly impact our understanding of dynamical processes in matter at the atomic-scale and in real time. Established optical pumping schemes using femtosecond visible frequency laser pulses for excitation are extended into the THz frequency regime thereby enabling resonant excitation of bonds in correlated solid state materials (phonon pumping), to drive low energy electronic excitations, to trigger surface chemistry reactions, and to all-optically bias a material with ultrashort electric fields or magnetic fields. A linac-based THz source can supply stand-alone experiments with peak intensities two orders of magnitude stronger than existing laser-based sources, but when coupled with atomic-scale sensitive femtosecond x-ray probes it opens a new frontier in ultrafast science with broad applications to correlated materials, interfacial and liquid phase chemistry, and materials in extreme conditions.

36 MATERIALS SCIENCE↗

Study of gas-puff Z-pinches on COBRA

Gas-puff Z-pinch experiments were conducted on the 1 MA, 200 ns pulse duration Cornell Beam Research Accelerator (COBRA) pulsed power generator in order to achieve an understanding of the dynamics and instability development in the imploding and stagnating plasma. The triple-nozzle gas-puff valve, pre-ionizer, and load hardware are described. Specific diagnostics for the gas-puff experiments, including a Planar Laser Induced Fluorescence system for measuring the radial neutral density profiles along with a Laser Shearing Interferometer and Laser Wavefront Analyzer for electron density measurements, are also described. The results of a series of experiments using two annular argon (Ar) and/or neon (Ne) gas shells (puff-on-puff) with or without an on- (or near-) axis wire are presented. For all of these experiments, plenum pressures were adjusted to hold the radial mass density profile as similar as possible. Initial implosion stability studies were performed using various combinations of the heavier (Ar) and lighter (Ne) gasses. Implosions with Ne in the outer shell and Ar in the inner were more stable than the opposite arrangement. Current waveforms can be adjusted on COBRA and it was found that the particular shape of the 200 ns current pulse affected on the duration and diameter of the stagnated pinched column and the x-ray yield.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Minority carrier lifetime in mid-wavelength infrared InAs/InAsSb superlattices: Photon recycling and the role of radiative and Shockley-Read-Hall recombination mechanisms

The influence of radiative recombination on the minority carrier lifetime in mid-wavelength InAs/InAsSb superlattices was investigated. From the lifetime's dependence on temperature, photon recycling, and carrier concentration, it was demonstrated that radiative lifetime dominates for carrier concentrations >5 × 10{sup 14} cm{sup −3}, and Shockley-Read-Hall recombination starts to dominate the minority carrier lifetime for carrier concentrations <5 × 10{sup 14} cm{sup −3}. An observed increase of the minority carrier lifetime with increasing superlattice thickness was attributed to photon recycling, and good agreement between measured and theoretical values of the photon recycling factor was obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effective versus ion thermal temperatures in the Weizmann Ne Z-pinch: Modeling and stagnation physics

The difference between the ion thermal and effective temperatures is investigated through simulations of the Ne gas puff z-pinch reported by Kroupp et al. [Phys. Rev. Lett. 107, 105001 (2011)]. Calculations are performed using a 2D, radiation-magnetohydrodynamic code with Tabular Collisional-Radiative Equilibrium, namely Mach2-TCRE [Thornhill et al., Phys. Plasmas 8, 3480 (2001)]. The extensive data set of imaging and K-shell spectroscopy from the experiments provides a challenging validation test for z-pinch simulations. Synthetic visible images of the implosion phase match the observed large scale structure if the breakdown occurs at the density corresponding to the Paschen minimum. At the beginning of stagnation (−4 ns), computed plasma conditions change rapidly showing a rising electron density and a peak in the ion thermal temperature of ∼1.8 keV. This is larger than the ion thermal temperature (<400 eV) inferred from the experiment. By the time of peak K-shell power (0 ns), the calculated electron density is similar to the data and the electron and ion thermal temperatures are equilibrated, as is observed. Effective ion temperatures are obtained from calculated emission line widths accounting for thermal broadening and Doppler velocity shifts. The observed, large effective ion temperatures (∼4 keV) early in the stagnation of this Ne pinch can be explained solely as a combination of compressional ion heating and steep radial velocity gradients near the axis. Approximations in the modeling are discussed in regard to the higher ion thermal temperature and lower electron density early in the stagnation compared to the experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of radiative and non-radiative recombination on the minority carrier lifetime in midwave infrared InAs/InAsSb superlattices

Optical modulation response is used to study the influence of radiative, Shockley-Read-Hall, and Auger recombination processes on the minority carrier lifetime in a mid-wave infrared InAs/InAsSb superlattice. A comparison of calculated and measured temperature dependencies shows that the lifetime is influenced mainly by radiative recombination at low temperatures, resulting in an increase of the minority carrier lifetime from 1.8 μs at 77 K to 2.8 μs at 200 K. At temperatures above 200 K, Auger recombination increases rapidly and limits the lifetime. Shockley-Read-Hall limited lifetimes on the order of 10 μs are predicted for superlattices with lower background doping concentration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion Temperature and Hydrodynamic-Energy Measurements in a Z-Pinch Plasma at Stagnation

The time history of the local ion kinetic energy in a stagnating plasma was determined from Doppler-dominated line shapes. Using independent determination of the plasma properties for the same plasma region, the data allowed for inferring the time-dependent ion temperature, and for discriminating the temperature from the total ion kinetic energy. It is found that throughout most of the stagnation period the ion thermal energy constitutes a small fraction of the total ion kinetic energy; the latter is dominated by hydrodynamic motion. Both the ion hydrodynamic and thermal energies are observed to decrease to the electron thermal energy by the end of the stagnation period. It is confirmed that the total ion kinetic energy available at the stagnating plasma and the total radiation emitted are in balance, as obtained in our previous experiment. The dissipation time of the hydrodynamic energy thus appears to determine the duration (and power) of the K emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Second and Third Harmonic Measurements at the Linac Coherent Light Source

The Linac Coherent Light Source (LCLS) started user commissioning in October of 2009, producing Free Electron Laser (FEL) radiation between 800 eV and 8 keV [1]. The fundamental wavelength of the FEL dominates radiation in the beamlines, but the beam also produces nonnegligible levels of radiation at higher harmonics. The harmonics may be desirable as a source of harder X-rays, but may also contribute backgrounds to user experiments. In this paper we present preliminary measurements of the second and third harmonic content in the FEL. We also measure the photon energy cutoff of the soft X-ray mirrors to determine the extent to which higher harmonics reach the experimental stations. We present preliminary second and third harmonic measurements for LCLS. At low energies (below 1 keV fundamental) we measure less than 0.1% second harmonic content. The second harmonic will be present in the soft X-ray beam line for fundamental photon energies below approximately 1.1 keV. At low and high energies, we measure third harmonic content ranging from 0.5% to 3%, which is consistent with expectations. For both second and third harmonics, experimental work is ongoing. More rigorous analysis of the data will be completed soon.

43 PARTICLE ACCELERATORS↗

Report on Modifications to the BX12 and BX13 BC1 Dipoles

Emittance growth seen during the last commissioning run in the bunch compressor optics section, BC1, was blamed on inadequate dipole field quality. The significant linear and nonlinear field non-uniformities generated large horizontal dispersion errors beyond BC1. The linear dispersion after BC1 was corrected using two small 'corrector' quadrupoles placed in BC1 for this purpose, but the remaining nonlinear field caused growth of the normalized horizontal emittance of 40% or more. At best {gamma}{epsilon}{sub x} went from 1.2 {micro}m before BC1 up to 1.7 {micro}m after BC1. The problem was magnified by the larger-than-design energy spread in BC1 due to a long initial bunch length. To improve the field quality we decided to modify the two 'inner dipoles', BX12 and BX13, of the four magnet chicane during the four month down time in the Fall of 2007. Only the two inner dipoles were chosen because of the limited time available and the fact that the beam is particularly sensitive to field quality of the inner dipoles due to its very large transverse size when going through them. The modifications were completed in November and included new poles and a new pinning scheme. The outer dipoles were left unchanged.

43 PARTICLE ACCELERATORS↗

Operation and Upgrades of the LCLS*

The LCLS FEL began user operations in September 2009 with photon energies from 800eV to 2 KeV and pulse energies above 2 mJ. Both long pulse (50-200 femtosecond FWHM) and short pulse (<10 femtosecond FWHM at 150 uJ) pulses were delivered at user request. In addition the FEL was operated at fundamental photon energies up to 10 KeV in preparation for hard X-ray experiments. FEL operating parameters, performance and reliability results will be presented, in addition to plans for upgrades to the facility.

Accelerators,ACCPHY, XFEL↗

Operational Performance of LCLS Beam Instrumentation

The Linac Coherent Light Source (LCLS) X-ray FEL utilizing the last km of the SLAC linac has been operational since April 2009 and finished its first successful user run last December. The various diagnostics for electron beam properties including beam position monitors, wire scanners, beam profile monitors, and bunch length diagnostics are presented as well as diagnostics for the X-ray beam. The low emittance and ultra-short electron beam required for X-ray FEL operation has implications on the transverse and longitudinal diagnostics. The coherence effects of the beam profile monitors and the challenges of measuring fs long bunches are discussed.

43 PARTICLE ACCELERATORS↗

Arbitrary Lagrangian Eulerian Adaptive Mesh Refinement

This is a simulation code involving an ALE (arbitrary Lagrangian-Eulerian) hydrocode with AMR (adaptive mesh refinement) and pluggable physics packages for material strength, heat conduction, radiation diffusion, and laser ray tracing developed a LLNL, UCSD, and Berkeley Lab. The code is an extension of the open source SAMRAI (Structured Adaptive Mesh Refinement Application Interface) code/library. The code can be used in laser facilities such as the National Ignition Facility. The code is alsi being applied to slurry flow (landslides).

Koniges, A.↗