Engineering Papers⌕ Search

Engineering topics

Ferrara, S.

Publications and source records attributed to Ferrara, S..

Design of a high voltage delivery system for noble liquid time projection chambers

Noble liquid time projection chambers (TPCs) are a leading technology in the detection of ionizing radiation, particularly in applications such as accelerator neutrino physics, dark matter detection, and neutrinoless double beta decay. This work addresses the design considerations for implementing stable high voltage (HV) systems within large noble liquid TPCs, with a focus on the nEXO experiment. Utilizing insights from prior HV research and experimental investigations, we outline factors influencing HV stability and discuss design choices to improve stability and prevent electrical discharges. A novel HV delivery system concept is presented, tailored for the nEXO TPC, which incorporates these design considerations while also meeting the stringent radiopurity requirements of the nEXO neutrinoless double beta decay search. These design considerations and their specific implementation towards a HV delivery system offer guidance to future experiments applying high voltage in noble liquid environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

nEXO: neutrinoless double beta decay search beyond 10 28 year half-life sensitivity

The nEXO neutrinoless double beta (0νββ) decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in 136 Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of 10 28 years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of 1.35 × 10 28 yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. Furthermore, the effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

Event reconstruction in a liquid xenon Time Projection Chamber with an optically-open field cage

nEXO is a proposed tonne-scale neutrinoless double beta decay (0νββ) experiment using liquid 136 Xe (LXe) in a Time Projection Chamber (TPC) to read out ionization and scintillation signals. Between the field cage and the LXe vessel, a layer of LXe (“skin” LXe) is present, where no ionization signal is collected. Only scintillation photons are detected, owing to the lack of optical barrier around the field cage. Here, in this work, we show that the light originating in the skin LXe region can be used to improve background discrimination by 5% over previous published estimates. This improvement comes from two elements. First, a fraction of the γ-ray background is removed by identifying light from interactions with an energy deposition in the skin LXe. Then, background from 222 Rn dissolved in the skin LXe can be efficiently rejected by tagging the α decay in the 214 Bi- 214 Po chain in the skin LXe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. In this work, we report the angular dependence of the specular reflectance in vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of an FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semitransparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are 1.97 ± 0.04 mm/µs and (-0.69 ± 0.05)%/K for liquid xenon, and 1.42 ± 0.03 mm/µs and (+0.11 ± 0.01)%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of 25.7±4.6 cm2/s and 149±23 cm2/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

Njoya, Oumarou↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Simulation of charge readout with segmented tiles in nEXO

nEXO is a proposed experiment to search for the neutrino-less double beta decay (0νββ) of 136 Xe in a tonne-scale liquid xenon time projection chamber (TPC). The nEXO TPC will be equipped with charge collection tiles to form the anode. In this work, the charge reconstruction performance of this anode design is studied with a dedicated simulation package. A multi-variate method and a deep neural network are developed to distinguish simulated 0νββ signals from backgrounds arising from trace levels of natural radioactivity in the detector materials. These simulations indicate that the nEXO TPC with charge-collection tiles shows promising capability to discriminate the 0νββ signal from backgrounds. Furthermore, the estimated half-life sensitivity for 0νββ decay is improved by 20 32)% with the multi-variate (deep neural network) methods considered here, e sensitivity estimated in the nEXO pre-conceptual design report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmogenic production of 39 Ar and 37 Ar in argon

We have experimentally determined the production rate of 39 Ar and 37 Ar from cosmic ray neutron interactions in argon at sea level. Understanding these production rates is important for argon-based dark matter experiments that plan to utilize argon extracted from deep underground because it is imperative to know what the ingrowth of 39 Ar will be during the production, transport, and storage of the underground argon. These measurements also allow for the prediction of 39 Ar and 37 Ar concentrations in the atmosphere which can be used to determine the presence of other sources of these isotopes. Through controlled irradiation with a neutron beam that mimics the cosmic ray neutron spectrum, followed by direct counting of 39 Ar and 37 Ar decays with sensitive ultralow background proportional counters, we determined that the production rate from cosmic ray neutrons at sea level is expected to be (759 ± 128) atoms / (k Ar day) for 39 Ar, and (51.0 ± 7.4) atoms / (kg Ar day) for 37 Ar . We also performed a survey of the alternate production mechanisms based on the state of knowledge of the associated cross sections to obtain a total sea-level cosmic ray production rate of (1048 ± 133) atoms / (kg Ar day) for 39 Ar, (56.7 ± 7.5) atoms / (kg Ar day) for 37 Ar in underground argon, and (92 ± 13) atoms / (kg Ar day) for 37 Ar in atmospheric argon.

20 ≤ A ≤ 3839 ≤ A ≤ 58↗

Weak-Lensing Mass Calibration of the Atacama Cosmology Telescope Equatorial Sunyaev-Zeldovich Cluster Sample with the Canada-France-Hawaii Telescope Stripe 82 Survey

Mass calibration uncertainty is the largest systematic effect for using clustersof galaxies to constrain cosmological parameters. We present weak lensing mass measurements from the Canada-France-Hawaii Telescope Stripe 82 Survey for galaxy clusters selected through their high signal-to-noise thermal Sunyaev-Zeldovich (tSZ) signal measured with the Atacama Cosmology Telescope (ACT). For a sample of 9 ACT clusters with a tSZ signal-to-noise greater than five, the average weak lensing mass is (4.8 plus or minus 0.8) times 10 (sup 14) solar mass, consistent with the tSZ mass estimate of (4.7 plus or minus 1.0) times 10 (sup 14) solar mass, which assumes a universal pressure profile for the cluster gas. Our results are consistent with previous weak-lensing measurements of tSZ-detected clusters from the Planck satellite. When comparing our results, we estimate the Eddington bias correction for the sample intersection of Planck and weak-lensing clusters which was previously excluded.

Battaglia, N.↗

Weak-lensing mass calibration of the Atacama Cosmology Telescope equatorial Sunyaev-Zeldovich cluster sample with the Canada-France-Hawaii telescope stripe 82 survey

Mass calibration uncertainty is the largest systematic effect for using clusters of galaxies to constrain cosmological parameters. We present weak lensing mass measurements from the Canada-France-Hawaii Telescope Stripe 82 Survey for galaxy clusters selected through their high signal-to-noise thermal Sunyaev-Zeldovich (tSZ) signal measured with the Atacama Cosmology Telescope (ACT). For a sample of 9 ACT clusters with a tSZ signal-to-noise greater than five the average weak lensing mass is (4.8±0.8) ×10{sup 14} M{sub ⊙}, consistent with the tSZ mass estimate of (4.70±1.0) ×10{sup 14} M{sub ⊙} which assumes a universal pressure profile for the cluster gas. Our results are consistent with previous weak-lensing measurements of tSZ-detected clusters from the Planck satellite. When comparing our results, we estimate the Eddington bias correction for the sample intersection of Planck and weak-lensing clusters which was previously excluded.

79 ASTRONOMY AND ASTROPHYSICS↗