Engineering Papers⌕ Search

Engineering topics

Fast, James E.

Publications and source records attributed to Fast, James E..

At least 19 records

Seismic DAS observations of a large underground chemical explosion in dry tuff

On 18 October 2023 a 16.3-ton TNT equivalent chemical explosion was detonated underground at the Nevada National Security Site, generating a seismic event with a magnitude of 1.7 (Meyers et al., 2024). The associated seismic wavefield was measured on a Distributed Acoustic Sensing (DAS) array with slant range distances from 27 m – 1123 m. The first arriving phase traveled at an apparent velocity of about 2640 m s -1 from 27 m to 420 m slant range and about 2470 m s -1 from 505 m to 1123 m slant range according to the first arrival moveouts on the DAS data. The first arrival from the explosion temporarily saturated the cable from a slant range of 27 m – 186 m and 0.009 s to 0.084 s post detonation. From 186 m slant range to 420 m slant range, peak strain rates of 5.6 x 10 6 nm m -1 s -1 were observed for the first arrival phase. For the first arrival from 505 m slant range to 1123 m slant range, peak strain rates reduced to 8.0 x 104 nm m -1 s -1 . A comparison of the scaled accelerations computed from DAS, the geophone pairs, and the measurements of co-located accelerometer pairs show common agreement at the scaled ranges of the single point sensors. This study adds to the body of work reporting near-source DAS observations of the seismic wavefields generated by underground chemical explosions. These results indicate that near-source DAS observations can refine interpretations of phase identification from single-point sensor observations. Phase identification could be one mechanism that contributes scatter to single point seismic measurements which would confound the performance of empirical relationships for small explosions. Removing that mechanism may therefore reduce interstation variability and increase empirical relationship performance for small explosions.

58 GEOSCIENCES↗

Low Yield Nuclear Monitoring Physics Experiment 1 – Integrated Data Acquisition System Design and Initial Observations

The report documents the design of the Integrated Data AcQuisition (IDAQ) system and observations recorded during the first in a series of underground chemical explosions conducted on the Nevada National Security Site (NNSS) in southern Nevada. Experiments are funded as part of Low Yield Nuclear Monitoring (LYNM) research and development within the United States National Nuclear Security Administration NA-22 nuclear non-proliferation program. The series is part of the broader Physical Experiment 1 (PE1) being conducted in and around the P-tunnel facility on the NNSS. Each explosive experiment utilizes several tons of comp-B to generate signals recorded by a broad suite of instrumentation. The IDAQ serves as the backbone for all subsurface instrumentation providing precise time synchronization, remote control, data exfiltration and backup, along with recording several sensing modalities throughout the underground complex that includes ground motion, environmental conditions, and electromagnetic signals.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Highly Segmented Silicon Strip Detectors for Radiation Detection (LDRD Final Report)

Large area highly segmented silicon strip detectors were investigated for use in applied radiation detection applications. Two ASIC-based readout electronics solutions were tested for compatibility. During the analysis, it was determined that significant computational resources and highly specialized firmware are required to reconstruct the data into a meaningful data stream for generalized spectroscopic performance. Future investment in the technology and careful choice of readout ASIC is expected to demonstrate relevance in measuring high activity samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Argon-39 from locations near historic underground nuclear explosions

Measurement of radioactive gas seepage from an underground nuclear explosion is one of the primary methods to confirm whether an event was nuclear in nature. Radioactive noble gas indicators that are commonly targeted by such measurements (e.g. 133Xe, 37Ar) have half-lives of 35 days or less. Argon-39, an activation product similar to 37Ar, is produced by the interaction between neutrons and potassium in the surrounding geology and has a half-life of 269 years. Measurements taken at three sites near three historic underground nuclear test locations at the Nevada National Security Site have all shown highly elevated levels of 39Ar in subsurface air decades after the test events. Elevated levels of 39Ar (30-50 times background) were also detected in atmospheric air collected roughly 30 cm above ground level near two of these sites, and outside the entrance of the one tunnel site. These measurements demonstrate that 39Ar has the potential to be a long-term signature of an underground nuclear event which can be reliably detected at the surface or in the shallow subsurface. This radionuclide detection of an underground nuclear event decades after the event takes place is in contrast to the commonly held assumption that detecting underground nuclear events via radionuclides at the surface needs to be done in a matter of months. Depending upon what further studies show about the robustness of this signature in a variety of geological settings, it may in fact be easy to detect underground nuclear events at the surface for a very long time post-detonation.

Johnson, Christine M.↗

UNESE Phase 2: Injection and measurement of gaseous tracers at U-12p Tunnel

In June 2018 radioactive ( 37 Ar and 127 Xe) and stable (SF 6 ) tracers were injected into the chimney of the Disko Elm underground nuclear explosion, located in the U-12p tunnel complex. After the injection sampling was performed from locations within the tunnel, a borehole drilled from the surface, and from the surface of the mesa. Additionally, the 127 Xe activity within the chimney was continuously monitored for two months after the injection. While none of the injected radiotracers were detected in the monitoring borehole, elevated levels of 39 Ar (an activation product produced by underground nuclear explosions) were detected and quantified in each sample.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Migration of noble gas tracers at the site of an underground nuclear explosion at the Nevada National Security Site

As part of an underground gas migration study, two radioactive noble gases and two stable tracer gases were injected into a nuclear explosion test chimney and allowed to migrate naturally. Soil gas samples were collected from a series of boreholes and a range of depths from the shallow subsurface (3 meters) to deeper levels (~160 meters) over a period of eleven months. These samples have provided insights into the development and evolution of the subsurface plume and constrained the relative migration rates of the radioactive and stable gas species. Analysis of the samples concluded that the stable tracer SF6 was consistently enriched in the subsurface samples relative to the radiotracer 127Xe, but the ratios of SF6 and 37Ar remained similar throughout the samples.

Johnson, Christine M.↗

Search for Neutrinoless Double-ß Decay in 76Ge with the Majorana Demonstrator

The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is comprised of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. Given the unprecedented energy resolution at Q of 2.5 keV FWHM and the very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, we find a lower limit on the half-life of 1:9 x 1025 yr (90% CL). This result constrains the effective Majorana neutrino mass to below 250 to 550 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4:0 +3:1(superscript) -2:5 (subscript) counts/(FWHM t yr) at 68% CL.

Aalseth, Craig E.↗

The Belle II imaging Time-of-Propagation (iTOP) Detector

High precision flavor physics measurements are an essential complement to the direct searches for new physics at the LHC. Such measurements will be performed using the upgraded Belle II detector that will take data at the SuperKEKB accelerator. With 40x the luminosity of KEKB, the detector systems must operate eciently at much higher rates than the original Belle detector. A central element of the upgrade is the barrel particle identication system. Belle II has built and installed an imaging-Time-of-Propagation (iTOP) detector. The iTOP uses quartz optics as Cerenkov radiators. The photons are transported down the quart bars via total internal reection with a spherical mirror at the forwardend to reflect photons to the backward end where they are imaged onto an array of segmented Micro-Channel Plate Photo-Multiplier Tubes. The system is readout using gigsample per second waveform sampling Application-Specific Integrated Circuits that provide precise photon timing. The combined timing and spatial distribution of the photons for each event are used to determine particle species. This paper provides an overview of the iTOP system.

Fast, James E.↗

Measurement of the 235U Induced Fission Gamma-ray Spectrum as an Active Non-destructive Assay of Fresh Nucleear Fuel

Non-destructive assay is a powerful tool the International Atomic Energy Agency (IAEA) employs to verify adherence to safeguards agreements. Current IAEA veri- cation techniques for fresh nuclear fuel include passive gamma-ray spectroscopy to determine fuel enrichment. This technique suers from self-shielding and lakes the percision to detect diversion of central fuel rods. The aim of this research is to develop a new, more capable non-destructive analysis technique using active neutron interroga- tion of fuel assemblies and determining the yields of short-lived ssion products from high-resolution gamma-ray spectroscopy using high-purity germanium (HPGe). This paper reports results from irradiation of a one meter tall mock fresh fuel assembly with low enriched uranium (LEU) or depleted uranium (DU) rods using a down-scattered deuterium-tritium (D-T) neutron source. Both prompt and delayed gamma-ray spec- tra were collected as time-stamped list-mode data in a coax detector and without list mode data in a planar strip detector. No dierentiating signatures were observed in the prompt spectra in either detector; however, both detectors observed several short-lived ssion product signatures in LEU and not DU fuel, indicating that this technique has potential for determination of enrichment of fresh fuel assemblies. There were eight unique ssion products observed in the LEU spectra with the coax detector spectra, and three ssion products were observed in the LEU spectra with the strip detector.

Fission Gamma-ray Spectrum↗

Spatially-resolved HPGe Gamma-ray Spectroscopy of Swipe Samples

Measurement of swipe samples is a critical element of the National Technical Nuclear Forensics (NTNF) mission. A unique, portable, germanium gamma imager (GeGI-s) from PHDS Co may provide complementary information to current techniques for swipe sample screening. The GeGI-s is a modified version of the commercial GeGI-4, a planar HPGe detector, capable of several million counts per second across the whole detector. The GeGI-s detector is a prototype of a commercial off-the-shelf high rate GeGI. The high rate capability allows high-activity samples be placed directly on the face of the detector. Utilizing the high energy resolution and pixelization of the detector, the GeGI-s can generate isotope specific spatial maps of the materials on the swipe sample. To prove this technology is viable for such mapping, the GeGI-s detector response to spatially distributed events must be well characterized. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The detection efficiency as a function of location has been characterized to understand the non-uniformities presented as a collimated photon beam was rastered vertically and horizontally across the face of the detector. The response was found to be primarily uniform and symmetric, however two causes of non-uniformity were found. Both of these causes can ultimately be corrected for in off-line data analysis.

germanium gamma imager↗

A Low-Noise Germanium Ionization Spectrometer for Low-Background Science

Recent progress on the development of very low energy threshold high purity germanium ionization spectrometers has produced an instrument of 1.2 kg mass and excellent noise performance. The detector was installed in a low-background cryostat intended for use in a low mass, WIMP dark matter direct detection search. The integrated detector and low background cryostat achieved noise performance of 98 eV full-width half-maximum of an input electronic pulse generator peak and gamma-ray energy resolution of 1.9 keV full-width half-maximum at the 60Co gamma-ray energy of 1332 keV. This Transaction reports the thermal characterization of the low-background cryostat, specifications of the newly prepared 1.2 kg p-type point contact germanium detector, and the ionization spectroscopy – energy resolution and energy threshold – performance of the integrated system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic Uncertainties in High-Rate Germanium Data

For many nuclear material safeguards inspections, spectroscopic gamma detectors are required which can achieve high event rates (in excess of 10^6 s^-1) while maintaining very good energy resolution for discrimination of neighboring gamma signatures in complex backgrounds. Such spectra can be useful for non-destructive assay (NDA) of spent nuclear fuel with long cooling times, which contains many potentially useful low-rate gamma lines, e.g., Cs-134, in the presence of a few dominating gamma lines, such as Cs-137. Detectors in use typically sacrifice energy resolution for count rate, e.g., LaBr3, or visa versa, e.g., CdZnTe. In contrast, we anticipate that beginning with a detector with high energy resolution, e.g., high-purity germanium (HPGe), and adapting the data acquisition for high throughput will be able to achieve the goals of the ideal detector. In this work, we present quantification of Cs-134 and Cs-137 activities, useful for fuel burn-up quantification, in fuel that has been cooling for 22.3 years. A segmented, planar HPGe detector is used for this inspection, which has been adapted for a high-rate throughput in excess of 500k counts/s. Using a very-high-statistic spectrum of 2.4*10^11 counts, isotope activities can be determined with very low statistical uncertainty. However, it is determined that systematic uncertainties dominate in such a data set, e.g., the uncertainty in the pulse line shape. This spectrum offers a unique opportunity to quantify this uncertainty and subsequently determine required counting times for given precision on values of interest.

burn-up↗

Studies of charmed strange baryons in the Λ D final state at Belle

In this report, we discuss the discovery of Ξ c ( 3055 ) 0 , observed by its decay into the final-state Λ D 0 , and present the first observation and evidence of the decays of Ξ c ( 3055 ) + and Ξ c ( 3080 ) + into Λ D + . Furthermore, we perform a combined analysis of the Λ D + with the Σ c + + K - and Σ c * + + K - decay modes to measure the ratios of branching fractions, masses and widths with improved accuracy. We measure the ratios of branching fractions B ( Ξ c ( 3055 ) + → Λ D + ) / B ( Ξ c ( 3055 ) + → Σ c + + K - ) = 5.09 ± 1.01 ± 0.76 , B ( Ξ c ( 3080 ) + → Λ D + ) / B ( Ξ c ( 3080 ) + → Σ c + + K - ) = 1.29 ± 0.30 ± 0.15 , and B ( Ξ c ( 3080 ) + → Σ c * + + K - ) / B ( Ξ c ( 3080 ) + → Σ c + + K - ) = 1.07 ± 0.27 ± 0.04 , where the uncertainties are statistical and systematic. The analysis is performed using a 980 fb - 1 data sample collected with the Belle detector at the KEKB asymmetric-energy e + e - collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of γ γ → p p ¯ K + K - and search for exotic baryons in p K systems

The process γ γ → p p ¯ K + K - and its intermediate processes are measured for the first time using a 980 fb - 1 data sample collected with the Belle detector at the KEKB asymmetric-energy e + e - collider. The production of p p ¯ K + K - and a Λ ( 1520 ) 0 ( Λ ¯ ( 1520 ) 0 ) signal in the p K - ( p ¯ K + ) invariant mass spectrum are clearly observed. However, no evidence for an exotic baryon near 1540 MeV / c 2 , denoted as Θ ( 1540 ) 0 ( Θ ¯ ( 1540 ) 0 ) or Θ ( 1540 ) + + ( Θ ( 1540 ) - -- ), is seen in the p K - ( p ¯ K + ) or p K + ( p ¯ K - ) invariant mass spectra. Cross sections for γ γ → p p ¯ K + K - , Λ ( 1520 ) 0 p ¯ K + + c . c . and the products σ ( γ γ → Θ ( 1540 ) 0 p ¯ K + + c . c . ) B ( Θ ( 1540 ) 0 → p K - ) and σ ( γ γ → Θ ( 1540 ) + + p ¯ K - + c . c . ) B ( Θ ( 1540 ) + + → p K + ) are measured. We also determine upper limits on the products of the χ c 0 and χ c 2 two-photon decay widths and their branching fractions to p p ¯ K + K - at the 90% credibility level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement Background and the Sediment Age-Dating Reach of 32Si

Silicon-32 has been identified as an isotope that fills the sediment geochronology gap created between Pb-210 at <150 years and C-14 at >1000 years. However, detector sensitivity and chemical isolation challenges of radiometric Si-32 for age dating have resulted in a fairly limited number of applications of this technique to real-world sediment studies. The significance of targeting the intermediate age bracket is to provide accurate geochronological reconstructions of paleoindicators that identify human and large-scale, climate-induced shifts in coastal areas. Therefore, we targeted Puget Sound, Washington, United States, to demonstrate the application of Si-32 age dating to determine the relative importance of climate cycles versus human activities in an in-land sea. The enhanced reconstructions will be achieved through the design of new detectors, chemical separation of biogenic silica from kilogram-scale sediment samples, and demonstration of the viable age-dating reach of Si-32. Implications of detector background on the duration of required measurements and the age-dating reach are considered. The design of a low-background, gas-proportional beta counter for measurement of the daughter isotope P-32 is discussed; detector background goals for these new detectors are based on the sensitivity study.

Keillor, Martin E.↗

Measurement of the decay B → D ℓ ν ℓ in fully reconstructed events and determination of the Cabibbo-Kobayashi-Maskawa matrix element | V c b |

We present a determination of the magnitude of the Cabibbo-Kobayashi-Maskawa matrix element |Vcb| using the decay B → Dℓν ℓ (ℓ = e,μ) based on 711 fb –1 of e + e – → Υ(4S) data recorded by the Belle detector and containing 772 × 10 6 BB¯ pairs. Here, one B meson in the event is fully reconstructed in a hadronic decay mode, while the other, on the signal side, is partially reconstructed from a charged lepton and either a D + or D 0 meson in a total of 23 hadronic decay modes. The isospin-averaged branching fraction of the decay B → Dℓν ℓ is found to be B(B 0 → D – ℓ + ν ℓ ) = (2.31 ± 0.03(stat) ± 0.11(syst))%. Analyzing the differential decay rate as a function of the hadronic recoil with the parametrization of Caprini, Lellouch, and Neubert and using the form-factor prediction G(1) = 1.0541 ± 0.0083 calculated by FNAL/MILC, we obtain η EW |V cb | = (40.12 ± 1.34) × 10 –3 , where ηEW is the electroweak correction factor. Alternatively, assuming the model-independent form-factor parametrization of Boyd, Grinstein, and Lebed and using lattice QCD data from the FNAL/MILC and HPQCD collaborations, we find η EW |V cb | = (41.10 ± 1.14) × 10 –3 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of the decay B 0 → ψ ( 2 S ) π 0

We report a measurement of the B 0 → ψ(2S)π 0 branching fraction based on the full Υ(4S) data set of 772 × 10 6 BB¯ pairs collected by the Belle detector at the KEKB asymmetric-energy e + e – collider. We obtain B(B 0 → ψ(2S)π 0 ) = (1.17 ± 0.17(stat) ± 0.08(syst)) × 10 –5 . Here, the result has a significance of 7.2 standard deviations and is the first observation of the decay B 0 → ψ(2S)π 0 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of B 0 → p Λ ¯ D ( * ) -

We report the first observation of the decays B 0 →p$\bar{Λ}$D(*)-. The data sample of 711 fb -1 used in this analysis corresponds to 772 million $B$$\bar{B}$ pairs, collected at the Υ(4S) resonance by the Belle detector at the KEKB asymmetric-energy e + e - collider. We observe 19.8σ and 10.8σ excesses of events for the two decay modes and measure the branching fractions of B 0 →p$\bar{Λ}$D- and B 0 →p$\bar{Λ}$D(*)- to be (25.1±2.6±3.5)×10 -6 and (33.6±6.3±4.4)×10 -6 , respectively, where the first uncertainties are statistical and the second are systematic. These results are not compatible with the predictions based on the generalized factorization approach. In addition, a threshold enhancement in the di-baryon (p$\bar{Λ}$) system is observed, consistent with that observed in similar B decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗