Engineering Papers⌕ Search

Engineering topics

Fagan, Deborah K.

Publications and source records attributed to Fagan, Deborah K..

Sampling and Analysis Plan for LSL2 Underground Storage Tank Evaluation of PFAS in Soil: Protection of Groundwater

This SAP gathers all pertinent information relevant to the sampling and analysis of soil at the removal site for a former 10,000-gallon UST and reference sites in the vicinity of the excavation site. Data Quality Objectives establishes the process and steps for the acquisition of data. Data Flow Diagram establishes the decisions and next steps. Quality Assurance Project Plan establishes the quality requirements for data collection, including planning, implementation, and assessment of sampling, field measurements, and laboratory analysis. The work is being completed for DOE-SC Pacific Northwest Site Office.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of a Methodology for Calculating the A Priori Scan Minimum Detectable Concentration for Post-Processed Radiological Surveys (Final Report) (Rev.1)

Increased continuous data collection using automated data loggers and autonomous radiological survey devices or vehicles has introduced a need for corresponding guidance and statistical techniques for data that are collected without surveyor vigilance. This report presents a method for calculating the a priori scan minimum detectable concentrations (MDCs) for surveys performed without vigilance similar to methods described in the Multi-Agency Radiation Survey and Site Investigation Manual, NUREG-1507, and NUREG/CR-6364. A priori scan MDCs are calculated during survey planning to ensure that survey parameters (e.g., scanning speed, scanning altitude, detector geometry) will lead to collecting data in which potentially contaminated areas can be detected when data are processed after the survey, within acceptable statistical error probabilities.

54 ENVIRONMENTAL SCIENCES↗

Drones for Decommissioning

The U.S. Nuclear Regulatory Commission has responsibility for regulating the safe decommissioning of facilities and sites to meet the License Termination Rule in 10 Code of Federal Regulations (CFR) Part 20, Standards for Protection Against Radiation, Subpart E “Radiological Criteria for License Termination.” Decommissioning is performed in accordance with 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, as part of license termination (§50.82) and release of the facility or site for unrestricted use (§50.83). The guidance currently demonstrates the minimum requirements and necessary conditions for conducting radiological surveys by a person carrying a radiation detector(s). The Pacific Northwest National Laboratory (PNNL) evaluated the use of an unoccupied aerial vehicle (UAV) to conduct radiological surveys that could be used in decommissioning to potentially reduce time, cost, and worker safety compared to current survey methods. The objective of this project was to evaluate the performance and limitations of a UAV to support a decommissioning radiological survey and compare it to a radiological survey conducted by a human. The primary research questions of interest evaluated were: 1. Did observed UAV paths differ from human paths and, if so, how much? 2. Did survey path deviation affect survey results and, if so, how? 3. Were radiological measurements from human and UAV surveys significantly different? To answer these research questions, an experimental field was set up at PNNL’s 3440 test track, and it included radiological sources commonly surveyed during decommissioning: cobalt-60 (Co-60), cesium-137 (Cs-137), and americium-241 (Am-241). Nine check sources (three each of Am-241, Cs-137, and Co-60) with activities ranging from 3.54 µCi to 39.34 µCi were set over a path that also included an area for measuring background radiation. An Aurelia X6 UAV coupled with a GPS and lidar unit was used to conduct the radiological surveys. UAV and human surveys were conducted using two different NaI(Tl) scintillation radiation detectors (2 in. × 2 in. Ludlum, Inc. and 2 in. × 0.04 in. Alpha Spectra, Inc.) at a travel velocity of approximately 0.2 m/s at a low (15–40 cm median altitude) or high (87–105 cm median altitude) survey altitude. Since the survey velocity and altitude parameters were atypical for normal UAV operations, testing was done prior to conducting the radiological surveys to establish airworthiness, evaluate the navigation system, and establish flight control. Human and UAV surveys were paired according to the detector type and altitude regime to compare the survey data. The results of this proof-of-concept research determined that the UAV and human surveys followed similar survey paths and detected the radiological sources with no significant statistical difference (in 33 out of 36 surveys). However, further research is needed prior to deploying UAVs for decommissioning surveys.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗