Engineering PapersSearch

Engineering topics

Faddoul, J. R.

Publications and source records attributed to Faddoul, J. R..

Improved Stud Designs for Wood/Metal Joints

Load-transfer capacities and resistances to fatigue increased. Series of high-strength bonded-stud designs developed for joining laminated wood to metal. Test results for bonded-stud designs demonstrated joint strengths approaching 10,000 to 12,000 psi (69 to 83 MPa) in ultimate strength and 5,000 psi (34 MPa) in high cycle fatigue strength of wood/epoxy composite achieved.

Faddoul, J. R.

Environmental Testing of Glass-Fiber/Epoxy Pressure Vessels

Pair of reports discusses long-term environmental tests of glassfiber/epoxy composite pressure vessels. Strength diminishes during long exposure to environment. Since such data necessary for accurate design of long-life structures such as pressure vessels, NASA Lewis Research Center built outdoor test stand in 1973. Test stand maintains system under constant pressure loading without frequent intervention of personnel.

Faddoul, J. R.

Ten year environmental test of glass fiber/epoxy pressure vessels

By the beginning of the 1970's composite pressure vessels had received a significant amount of development effort, and applications were beginning to be investigated. One of the first applications grew out of NASA Johnson Space Center efforts to develop a superior emergency breathing system for firemen. While the new breathing system provided improved wearer comfort and an improved mask and regulator, the primary feature was low weight which was achieved by using a glass fiber reinforced aluminum pressure vessel. Part of the development effort was to evaluate the long term performance of the pressure vessel and as a consequence, some 30 bottles for a test program were procured. These bottles were then provided to NASA Lewis Research Center where they were maintained in an outdoor environment in a pressurized condition for a period of up to 10 yr. During this period, bottles were periodically subjected to cyclic and burst testing. There was no protective coating applied to the fiberglass/epoxy composite, and significant loss in strength did occur as a result of the environment. Similar bottles stored indoors showed little, if any, degradation. This report contains a description of the pressure vessels, a discussion of the test program, data for each bottle, and appropriate plots, comparisons, and conclusions.

Faddoul, J. R.

Ten year environmental test of glass fiber/epoxy pressure vessels

By the beginning of the 1970's composite pressure vessels had received a significant amount of development effort, and applications were beginning to be investigated. One of the first applications grew out of NASA Johnson Space Center efforts to develop a superior emergency breathing system for firemen. While the new breathing system provided improved wearer comfort and an improved mask and regulator, the primary feature was low weight which was achieved by using a glass fiber reinforced aluminum pressure vessel. Part of the development effort was to evaluate the long term performance of the pressure vessel and as a consequence, some 30 bottles for a test program were procured. These bottles were then provided to NASA Lewis Research Center where they were maintained in an outdoor environment in a pressurized condition for a period of up to 10 yr. During this period, bottles were periodically subjected to cyclic and burst testing. There was no protective coating applied to the fiberglass/epoxy composite, and significant loss in strength did occur as a result of the environment. Similar bottles stored indoors showed little, if any, degradation. This report contains a description of the pressure vessels, a discussion of the test program, data for each bottle, and appropriate plots, comparisons, and conclusions.

Faddoul, J. R.

Examination, evaluation and repair of laminated wood blades after service on the Mod-OA wind turbine

Laminated wood blades were designed, fabricated, and installed on a 200-KW wind turbine (Mod-OA). The machine uses a two-blade rotor with a diameter of 38.1 m (125 ft). Each blade weights less than 1361 kg (3000 lb). After operating in the field, two blade sets were returned for inspection. One set had been in Hawaii for 17 months (7844 hr of operation) and the other had been at Block Island, Rhode Island, for 26 months (22 months operating - 7564 hr). The Hawaii set was returned because of one of the studs that holds the blade to the hub had failed. This was found to be caused by a combination of improper installation and inadequate corrosion protection. No other problems were found. The broken stud (along with four others that were badly corroded) was replaced and the blades are now in storage. The Block Island set of blades was returned at the completion of the test program, but one blade was found to have developed a crack in the leading edge along the entire span. This crack was found to be the result of a manufacturing process problem but was not structurally critical. When a load-deflection test was conducted on the cracked blade, the response was identical to that measured before installation. In general, the laminate quality of both blade sets was excellent. No significant internal delamination or structural defects were found in any blade. The stud bonding process requires close tolerance control and adequate corrosion protection, but studs can be removed and replaced without major problems. Moisture content stabilization does not appear to be a problem, and laminated wood blades are satisfactory for long-term operation on Mod-OA wind turbines.

Faddoul, J. R.

Structural fatigue test results for large wind turbine blade sections

In order to provide quantitative information on the operating life capabilities of wind turbine rotor blade concepts for root-end load transfer, a series of cantilever beam fatigue tests was conducted. Fatigue tests were conducted on a laminated wood blade with bonded steel studs, a low cost steel spar (utility pole) with a welded flange, a utility pole with additional root-end thickness provided by a swaged collar, fiberglass spars with both bonded and nonbonded fittings, and, finally, an aluminum blade with a bolted steel fitting (Lockheed Mod-0 blade). Photographs, data, and conclusions for each of these tests are presented. In addition, the aluminum blade test results are compared to field failure information; these results provide evidence that the cantilever beam type of fatigue test is a satisfactory method for obtaining qualitative data on blade life expectancy and for identifying structurally underdesigned areas (hot spots).

Faddoul, J. R.

Test evaluation of a laminated wood wind turbine blade concept

A series of tests conducted on a root end section of a laminated wood wind turbine blade are reported. The blade to hub transition of the wood blade uses steel studs cast into the wood D spar with a filled epoxy. Both individual studs and a full scale, short length, root section were tested. Results indicate that the bonded stud concept is more than adequate for both the 30 year life fatigue loads and for the high wind or hurricane gust loads.

Faddoul, J. R.

Preliminary evaluation of fiber composite reinforcement of truck frame rails

The use of graphite fiber/resin matrix composite to effectively reinforce a standard steel truck frame rail is studied. A preliminary design was made and it was determined that the reinforcement weight could be reduced by a factor of 10 when compared to a steel reinforcement. A section of a 1/3 scale reinforced rail was fabricated to demonstrate low cost manufacturing techniques. The scale rail section was then tested and increased stiffness was confirmed. No evidence of composite fatigue was found after 500,000 cycles to a fiber stress of 34,000 psi. The test specimen failed in bending in a static test at a load 50 percent greater than that predicted for a non-reinforced rail.

Faddoul, J. R.

Cost/benefit assessment of the application of composite materials to subsonic commercial transport engines

Results from a number of studies concerned with the cost and benefits of applying advanced composite materials to commercial turbofan engines are summarized. For each application area the optimistic and pessimistic benefit projections were averaged to arrive at a projected yearly percentage fuel savings for a commercial fleet of advanced technology transport aircraft. Engine components included in the summary are the fan section which includes fan blades, fan frame/case, and the blade containment ring; the nacelle; and the high pressure turbine blades and vanes. The projected fuel savings resulting from the application of composites are 1.85 percent for the fan section, 1.75 percent for the nacelle, and 2.35 percent for the high pressure turbine.

Faddoul, J. R.

Structural considerations in design of lightweight glass-fiber composite pressure vessels

The development of structurally efficient, metal-lined, glass-fiber composite pressure vessels. Both the current state-of-the-art and current problems are discussed along with fracture mechanics considerations for the metal liner. The design concepts used for metal-lined, glass-fiber, composite pressure vessels are described and the structural characteristics of the composite designs are compared with each other and with homogeneous metal pressure vessels. Specific design techniques and available design data are identified. Results of a current program to evaluate flaw growth and fracture characteristics of the metal liners are reviewed and the impact of these results on composite pressure vessel designs is discussed.

Faddoul, J. R.

Structural considerations in design of lightweight glass-fiber composite pressure vessels

The design concepts used for metal-lined glass-fiber composite pressure vessels are described, comparing the structural characteristics of the composite designs with each other and with homogeneous metal pressure vessels. Specific design techniques and available design data are identified. The discussion centers around two distinctly different design concepts, which provide the basis for defining metal lined composite vessels as either (1) thin-metal lined, or (2) glass fiber reinforced (GFR). Both concepts are described and associated development problems are identified and discussed. Relevant fabrication and testing experience from a series of NASA-Lewis Research Center development efforts is presented.

Faddoul, J. R.

Application of composite materials to space shuttle tanks

Tanks are broken down into two categories: pressure vessels that carry primarily pressure loads, and structural tanks that carry structural loads such as thrust or bending in addition to pressure. A significant portion of the shuttle orbiter structure are tanks and in order to minimize both weight and cost growth on these shuttle tank structures, composite material tanks of both types are considered.

Faddoul, J. R.

Rigid open-cell polyurethane foam for cryogenic insulation

Lightweight polyurethane foam assembled in panels is effective spacer material for construction of self-evacuating multilayer insulation panels for cryogenic liquid tanks. Spacer material separates radiation shields with barrier that minimizes conductive and convective heat transfer between shields.

Faddoul, J. R.