Fabris, Lorenzo

Publications and source records attributed to Fabris, Lorenzo.

At least 19 records

Workshop on Radiographic Imaging and Applications Research and Development Recommendations for Field Radiography

The Workshop on Radiographic Imaging and Applications (WORIA) brought together subject matter experts from industry, academia, US and UK government agencies, and the national laboratories to provide a forum to liaise and share information between technology developers in government and industry, end users, and mission stakeholder to produce an “expert consensus view” regarding future research directions toward a comprehensive radiography/penetrating imaging portfolio in the Defense Nuclear Nonproliferation Research and Development Near Field Detection Portfolio. The inaugural WORIA was held at the Spallation Neutron Source at Oak Ridge National Laboratory on February 7–9, 2023. The inaugural WORIA meeting focused on field radiography applications, or situations in which a portable imaging system must be brought to an item of interest (rather than the item brought to an imaging facility). This report documents consensus views derived from the meeting and provides research and development recommendations for federal program managers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ASIC Scoping Study Final Report

This report documents the results and findings of a one-year scoping study investigating multichannel readout application specific integrated circuits (ASICs) for interfacing to, and processing data from, silicon photomultiplier (SiPM) arrays. We document ASIC desired and required specifications for four applications supporting national security mission areas: neutron radiography, associated particle imaging, and two versions of kinematic neutron imaging cameras. While each application has a few unique requirements that stress capability, there is generally good agreement among most. Two recently developed ASIC devices were evaluated in a system-like configuration by interfacing these to scintillator crystals exposed to gamma and neutron sources. The 64-channel ORNL device delivered functional capability while meeting most mission requirements for neutron radiography. The Nalu Scientific device, a 32-channel full waveform digitizer, did not demonstrate reliable neutron / gamma separation but it is unclear if this was an ASIC issue or problems with test setup or firmware. A literature survey of other commercial and academic ASICs was undertaken to with the conclusion that existing devices do not meet all requirements.

42 ENGINEERING↗

Measurement of Electron-Neutrino Charged-Current Cross Sections on 127 I with the COHERENT NaI$ν$E Detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino chargedcurrent cross section on 127 I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy (≤ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of ${9.2}_{–1.8}^{+2.1}$ × 10 –40 cm 2 . This corresponds to a value that is ~41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on 127 I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be ${5.2}_{–3.1}^{+3.4}$ × 10 –40 and ${2.2}_{—2.2}^{+3.5}$ × 10 –40 cm 2 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 32-channels readout ASIC for X-ray spectrometry and tracking in the GAPS experiment

Here this work describes the architecture and the experimental results from the characterization of a 32-channels mixed-signal Application-Specific Integrated Circuit (ASIC) developed for the readout of the lithium-drifted silicon, Si(Li), detectors of the General AntiParticle Spectrometer (GAPS) experiment dedicated to searching for dark matter. The instrument is designed for the identification of antiprotons, antideuterons and antihelium nuclei from cosmic rays during an Antarctic balloon mission scheduled for late 2024. A full custom integrated circuit, named SLIDER32 (32-channels Si-LI DEtector Readout) ASIC, has been produced in a commercial 180 nm CMOS technology. The ASIC is comprised of 32 low-noise analog readout channels featuring dynamic signal compression to comply with the wide input range, an 11-bit SAR ADC and a digital back-end section which is responsible for channel setting and for sending digital information to the data acquisition system (DAQ). The circuit design criteria and the experimental results are discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel Cascaded Ring Oscillator Vernier based TDC Architecture with a Feedthrough Reference Oscillator

Time to digital converters (TDCs) are widely used in particle physics and medical imaging to determine the relative arrival time of photons and other particles. Vernier TDCs are one of the most attractive options due to their power consumption efficiency and their small footprint. We present our newly patented innovative architecture of cascaded-stage Vernier TDCs comprised of a feedthrough reference oscillator. This architecture lead to successive Vernier measurements that result in a lower number of cycles for the same dynamic range to resolution ratio (DRRR), leading to reduced conversion time and lower jitter. To validate this architecture, a test chip was designed in 0.18~μm TSMC technology, integrating four types of cascaded Vernier TDCs with an increasing number of stages. The performance of the chip was assessed using a modular test platform specifically designed for TDCs. For comparison purposes, all TDCs were tested with a LSB of 50~ps and a dynamic range of 20~ns. The experimental results demonstrate the highest gain in performance between 1 stage Vernier and 2 stage Vernier TDCs with the precision improved from 36~ps~rms to 21~ps~rms, the maximum number of turns from 110 to 25 counts and the dead time, from 266.4~ns to 76.5~ns, on average. Adding Vernier stages is only relevant for a higher DRRR. Therefore, the 3-stage and 4-stage Vernier TDCs also show performance gains, but improvements are limited.

Scarpellini, Robin↗

Experimental results from the characterization of a 32-channels mixed-signal processor for the GAPS experiment

This work describes the experimental results obtained from the characterization of a 32-channels readout ASIC that is the core of a module composed by 4 Lithium-drifted Silicon, Si(Li), detectors. The module is the building block of a tracker in an upcoming balloon experiment. The activity is carried out within the General AntiParticle Spectrometer (GAPS) international collaboration, whose objective is the indirect detection of dark matter through the detection of antiparticles present in cosmic rays at low energies. The balloon flight is foreseen in 2024 from the McMurdo station in Antarctica. The ASIC is designed in a 180 nm CMOS technology and has 32 low-noise analog readout channels featuring a dynamic compression of the signal, an 11-bit SAR ADC, and a digital back-end section responsible for channel setting and for sending digital information to the data acquisition system of the tracker. This work has a twofold goal: it intends on the one hand to verify the performance of the circuit, on the other to select at least 300 good samples to be used for the assembly of the GAPS Si(Li) tracker.

Riceputi, Elisa↗

Fast neutron radiography-based on single-photon digital photosensor: concept and demonstration

For decades, fast neutron radiography performed using pulse-counting detectors employed PMTs coupled to plastic scintillator pixel arrays. SiPM-based systems are now sought to replace fragile PMTs, but conventional, “analog” SiPMs suffer from intrinsic limitations which limit their achievable performance. Among these limitations, a complete analog readout and digitizer chain is required, a counterintuitive approach when considering that the single-photon avalanche diode (SPAD), the basic unit cell of SiPMs, is a Boolean detector providing digital detection at the sensor level. This paper outlines a new concept for neutron radiography instrumentation by using photon-to-digital converters (PDCs, aka digital SiPMs), a fully digital solution to sense the scintillation light.

Pratte, Jean-Francois↗

Characterization of the ORNL SiPM PSD ASIC's Basic Properties

ORNL has developed an ASIC intended for reading out arrays of Silicon Photomultipliers coupled to scintillator materials that exhibit neutron/gamma pulse shape discrimination. The ASIC's basic properties: power consumption, linearity, PSD FoM, and timing resolution have all been measured and the results are presented here.

47 OTHER INSTRUMENTATION↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon-to-Digital Converters for Neutron Imaging Instruments (Final Report)

Oak Ridge National Laboratory (ORNL) collaborated with the Université de Sherbrooke (UdeS) to design a modular and scalable tile of innovative digital photodetectors called Photon-to-Digital Converters (PDC) and the required subsystems to demonstrate the feasibility of large area single-photon detectors to support high-resolution, depth-of-interaction, fast neutron radiography based on scintillation detectors. The goal is to demonstrate the advantages of using PDC over conventional Silicon Photomultiplier (SiPM) for neutron imaging systems. The basic building blocks of analog SiPM and PDC are Single-Photon Avalanche Photodiodes (SPAD). The main difference between conventional SiPMs and PDCs, is in the fact that analog SiPMs sum the charge produced by individual SPAD passively, while in PDCs each SPAD is read out individually by an active electronic circuit. Hence, PDCs provide a direct photon-to-bit conversion where a logic “1” means that there was a detection in a given SPAD. Conversely, an analog SiPM requires a sophisticated preamplifier (current amplifiers or transimpedance amplifier) followed by a shaping amplifier and an analog-to-digital converter. Moreover, since the charge from each SPAD varies slightly, the passive sum of the analog SiPM will have signal fluctuations for the same amount of photon detected. This is one of many issues that is completely eliminated by individual one-to-one SPAD read out in PDCs. The large area required for scintillator readouts for neutron imaging is such that the output capacitance of a large area of SiPM arrays is very high. This creates a burden on the signal-to-noise optimization with respect to the power budget. For PDC, the power consumption is dictated by rate of the incident photon flux, or in photon-starved environments, the dark noise rate of the SPAD array. In other words, the power consumption in the absence of events is extremely low. Hence, the power consumption of a PDC read out system is much lower than its analog counterpart. Further, the large SiPM capacitance may introduce signal distortions on the scintillator fast rise or decay time with undesired effects on timing and pulse shape discrimination. The problem is absent in PDCs, as their readout is independent on device capacitance. UdeS is the world leader in 3D vertical integration of frontside illuminated SPAD arrays over CMOS readouts. These capabilities allow future production of “3D PDC” with maximum photosensitive fill factor and electronic functionalities tailored to the application. UdeS' vast knowledge of SPADs and CMOS design made the team an ideal collaborator in the development of large area high-resolution fast neutron radiography.

42 ENGINEERING↗

A novel silicon photomultiplier readout architecture for low-light applications

In this article we describe the photon detection readout electronics for the nEDM@SNS experiment. The chosen "photon counting" architecture, which utilizes high-efficiency silicon photomultipliers (SiPMs) and is appropriate for low-light applications, allows the use of a relatively high SiPM operating voltage. This maximizes photon detection efficiency and minimizes gain/efficiency voltage-dependence while eliminating direct optical cross-talk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REDC Process Instrumentation Modernization Project

Critical electronics used for isotopes production have become outdated and difficult to manufacture. In particular the alpha-particle and neutron detection electronics (commonly referred to as Q2809A-9 and -11) which are used to monitor effluent activity in ORNL Building 7920 were designed and deployed in 1966-67. These electronics are still used but some parts are no longer available for purchase. In addition, the printed circuit boards used in the Count Rate Monitor (CRM) module have no fabrication files or quality assurance documentation. In light of this, a project to modernize the modules for ability to manufacture with modern parts was undertaken. Both the preamplifier and CRM were modernized with new printed circuit boards and parts which are current catalog parts. In addition, QA documentation was generated which allows the manufacturer to assure proper operation prior to delivery.

42 ENGINEERING↗

Initial Measurements with the Prototype Parallel-Slit Ring Collimator Fast Neutron Emission Tomography System

Since 2017, Oak Ridge National Laboratory (ORNL) has been developing a passive fast-neutron emission tomography capability. The goal of this development is the ability to quantify the neutron source strength of individual fuel pins (rods) in spent nuclear fuel assemblies. Such a system could be used to measure the burnup of each fuel pin in a spent fuel assembly to take burnup credit when loading dry storage casks or to count individual fuel pins in spent fuel assemblies for safeguards purposes. At present, a laboratory prototype imager has been built and initial imaging measurements performed. The purpose of this prototype is to demonstrate imaging capability sufficient to resolve individual fuel pins in spent fuel assemblies, and in initial measurements, neutron sources separated by a spacing of 1.27 cm (similar to the spacing between fuel pins in commercial pressurized water reactor 17×17 nuclear fuel assemblies) have been resolved. This report documents the as-built imager, first measurements performed with it, and tomographic reconstructions performed using the measured data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Frequency Domain Multiplexing Technique for Multi-Channel Detector Instrumentation

Radiation detection often requires several detectors to be employed at once. Normally, each detector outputs a signal that must be transported, digitized, and stored. One common format for these signals is a finite, aperiodic pulse. Since the detector and data acquisition system are not necessarily physically close, transporting signals from several detectors to a central data acquisition system often requires the use of many cables. The technique presented here allows for the combination and later recovery of a number of analog detector signals using a single cable, by shifting their content to narrow bands in the frequency domain and summing them together into a single channel for transmission. The output is a linear combination of decaying sinusoids, whose peak frequencies and bandwidths in the frequency domain are controlled by inductor, resistor, and capacitor values in the circuit. By separating the outputs by several megahertz, and lowering the bandwidth to about 1 MHz, we can isolate each signal. The timing of the original input can be recovered by taking the inverse Fourier transform of the isolated peak and identifying the start time of the resulting single decaying sinusoid. The energy of the input signal is proportional to the square root of the integral of the corresponding power spectrum peak. We show that energy spectra can be reconstructed with minimal additions to energy resolution. We also show that coincidence timing measurements can be performed with an uncertainty smaller than 2 ns. The result is an N to 1 reduction in cabling, with obvious cost and complexity gains. Since most of the signal content exists only in a band around each peak frequency, noise outside of these bands does not impact the performance.

Belling, Samuel↗

DEVELOPMENT OF A NUCLEAR FUEL SAFEGUARDS VERIFICATION TECHNOLOGY FOR NEW FACILITY TYPES: Use of fast neutron emission tomography for spent fuel verification

With the buildup of spent fuel inventories around the world from decommissioning activities, a tool for the efficient and effective verification of a variety of fuel types for long-term disposition is needed. Fast neutron emission tomography is a promising imaging technology that can address this problem and has been under development at Oak Ridge National Laboratory for the past two years. The goal of this capability is to detect the removal or substitution of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications. The present imaging technique is based on neutron emissions originating primarily from curium-244, which is produced predominantly at the end of the exposure cycle. As a result, this technique may be sensitive not only to fuel pins that are removed or substituted subsequent to all irradiation, but also to fuel pins that are substituted and subsequently irradiated. At present, a laboratory prototype imager is under construction. The purpose of the prototype is to demonstrate an imaging capabilitysufficient to resolve individual fuel pins using commercially available boron straw detectors that can withstand the high gamma ray dose from a typical spent fuel assembly. To achieve both practical measurement durations and sufficient resolution to discern individual pins, the prototype imager employs a novel collimator design where the slits of a parallel-slit collimator are rearranged to distribute them around a ring surrounding the target fuel assembly. This paper will report on simulations and experimental results undertaken to converge on a final design, image reconstruction of sample fuel types of interest, and challenges associated.

Iyengar, Anagha↗

Commercial Design of Custom Front-end Electronics for a High Temperature Fission Chamber

The next generation of advanced nuclear reactor will require instrumentation designed to withstand higher temperatures and harsher environments. One of the most important instruments required to monitor power and in-core fuel management is a fission chamber. A fission chamber consists of a gas-filled chamber with a fissile coating on the inside of the chamber.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and implementation of a non-magnetic cryogenic multi-conductor vacuum feedthrough

Here, a common issue for experiments requiring very low magnetic fields on vacuum and cryogenic systems is how to deal with the control of magnetic properties of electrical contacts. We describe the design and implementation of a generic sixty-four pin non-magnetic cryogenic vacuum feedthrough capable of disconnecting contacts on both sides of the vacuum boundary.

47 OTHER INSTRUMENTATION↗