Engineering Papers⌕ Search

Engineering topics

Estrada, Juan

Publications and source records attributed to Estrada, Juan.

26 records · Page 2

Unraveling Fano noise and the partial-charge-collection effect in x-ray spectra below 1 keV

Fano noise, readout noise, and the partial-charge-collection (PCC) effect collectively contribute to the degradation of energy spectra in charge-coupled device (CCD) measurements, especially at low energies. Here, in this work, the x rays produced by the fluorescence of fluorine (677 eV) and aluminum (1486 eV) were recorded using a Skipper-CCD, which enabled the readout noise to be reduced to 0.2 e - . Based on an analytical description of photopeak shapes resulting from the convolution of the PCC effect and Fano noise, we achieved a precise characterization of the energy spectra. This description enabled us to disentangle and quantify the contributions from both Fano noise and the PCC effect. As a result, we determined the Fano factor and the electron-hole pair creation energy. Additionally, we estimated the PCC region of the sensor and, for the first time, experimentally observed the expected skewness of photopeaks at low energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Achieving Single-Electron Sensitivity at Enhanced Speed in Fully-Depleted CCDs with Double-Gate MOSFETs

We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer efficiency. The junction coupling between the CCD and MOSFET channels has enabled high sensitivity, demonstrating sub-electron readout noise in one pixel charge measurement. We have also demonstrated the non-destructive readout capability of the device. Achieving single-electron and single-photon per pixel counting in the entire CCD pixel array has been made possible through the averaging of a small number of samples. We have demonstrated fully-depleted CCD readout with better performance than the floating diffusion and floating gate amplifiers available today, in both single and multisampling regimes, boasting at least six times the speed of floating gate amplifiers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connector interface assembly for enclosed vessels and associated systems and methods

Systems, methods, and apparatus that employ a connector assembly having a substrate layer with an inner aperture and an outer periphery, and one or more signal traces disposed on the substrate that extend from an inner first location to an outer second location of the apparatus, for communicating data between electronic devices positioned within an interior volume of an enclosed vessel and complementary electronic devices positioned in an ambient environment external to the enclosed vessel. An inner connector is conductively connected the signal traces at the inner first location of each signal trace, and an outer connector is conductively connected to the one or more signal traces at the outer second location of each signal trace. A substantially flat exterior surface extends radially over at least a portion of a region between the respective first locations and the respective second locations.

Estrada, Juan↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device

A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier; measurements with multiple amplifiers can then be combined to further reduce the readout noise. The readout speed of this detector scales roughly linearly with the number of amplifiers without requiring segmentation of the active area. The performance of this detector is demonstrated, emphasizing the ability to resolve individual quanta and the ability to combine measurements across amplifiers to reduce readout noise. The unprecedented low noise and fast readout of the MAS-CCD make it a unique technology for astronomical observations, quantum imaging, and low-energy interacting particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DarkNESS Project Testing

This internship involved the design and assembly of a mechanical system for testing skipper-Charge Couple Devices (CCDs) for the DarkNESS project. Skipper-CCDs are highly-sensitive sensors with ultra-low readout noise that are deployed for direct detection of dark matter. DarkNESS is a CubeSat that aims to use skipper CCDs to search for dark matter decaying into X-rays. Currently, in the testing phase, the design process involved creating 3D models of mechanical adapters to operate a prototype space Multi Chip Module (sMCM) package in existing testing chambers in the CCD lab at Fermilab's IERC. The drawings were sent out to be machined, and while waiting to receive the finished adapters, we assembled a vacuum chamber for skipper-CCD testing and performed initial testing of a single CCD controlled by the space Low Threshold Acquisition (sLTA) board that will be employed on the CubeSat. The results showed that the testing conditions are optimal for data to start being taken and analyzed.

Akouedjinoude, Kodjo↗

A Sub-Electron-Noise Multi-Channel Cryogenic Skipper-CCD Readout ASIC

The MIDNA application specific integrated circuit (ASIC) is a skipper-CCD readout chip fabricated in a 65 nm LP-CMOS process that is capable of working at cryogenic temperatures. The chip integrates four front-end channels that process the skipper-CCD signal and performs differential averaging using a dual slope integration (DSI) circuit. Each readout channel contains a pre-amplifier, a DC restorer, and a dual-slope integrator with chopping capability. The integrator chopping is a key system design element in order to mitigate the effect of low-frequency noise produced by the integrator itself, and it is not often required with standard CCDs. Each channel consumes 4.5 mW of power, occupies 0.156 mm${^2}$ area and has an input referred noise of 2.7${\mu\nu}_{rms}$. It is demonstrated experimentally to achieve sub-electron noise when coupled with a skipper-CCD by means of averaging samples of each pixel. Here, sub-electron noise is shown in three different acquisition approaches. The signal range is 6000 electrons. The readout system achieves 0.2${e^{-}}$ RMS by averaging 1000 samples with MIDNA both at room temperature and at 180 Kelvin.

1/f noise↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus ‘super-resolution’). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

47 OTHER INSTRUMENTATION↗